14. Care and maintenance
In order to ensure a trouble-free operation of the device, the combustion
chamber, the burner and the fan are to be cleaned regularly.
Switch the device off as described in the chapter "Functions and
operation".
Wait until the device has cooled down completely.
Cleaning after every 50 operating hours
Dismount the heating oil filter. Remove the filter insert and clean
it using clean heating oil.
Dismount the upper housing part and clean the inner part as well
as the fan blades using a cleaning fleece and a brass brush if it
is heavily soiled.
Check the condition of all cables and high-voltage connections.
Dismount the burner and clean its components using a brass
brush.
Clean the electrodes. Check the distance of the electrodes and
adjust it if required (see figure).
Have the combustion chamber cleaned by the customer service.
Mount the components in the reverse order.
Cleaning the oil heating unit
Wipe the exterior of the device using a wet cloth. The painted
and plastic surfaces may not be scoured. Do not use any solvent-
based cleaning agents.
15. Disposal
The heating oil must be drained from the tank of the oil heating unit and
collected.
Oil heating unit
Electronic equipment may not be disposed of in the domestic waste, but
must be correctly disposed of in accordance with the EUROPEAN PARLIA-
MENT directive 2002/96/EC of 27th January 2003 regarding used electri-
cal and electronic equipment. Please dispose of this device according to
the applicable legal regulations after its final decommissioning.
Heating oil
Fuels must be disposed of according to the local regulations.
Packaging
The packaging of the oil heating unit consists of cardboard/paper and
plastic. The materials must be disposed of in the designated containers
according to the local regulations or at a recycling depot.
16. Service and repair
Before contacting our customer service in order to solve an existing tech-
nical problem, please try removing the error by following the instructions
described in the chapter "Troubleshooting".
If you have any further questions regarding the functioning and operation
of the oil cleaning unit or if you wish to receive further information in
the event of a claim or with regard to guarantee aspects, please do not
hesitate to contact us at any time.
Please contact:
Trotec GmbH Co KG
Grebbener Straße 7
D-52525 Heinsberg
Tel.: 49 (0) 2452 / 962 - 400
Fax.: 49 (0) 2452 / 962 - 200
Email: [email protected]
www.trotec.de.
17. Troubleshooting
Danger to life due to improper repair!
Do no attempt to carry out modifications or repairs on
the device. Any unauthorised modification may result
in serious injuries or even death. Have repairs carried
out by a certified specialist workshop.