Trotec BT22WP Operating Manual Download Page 2

2

EN

smartphone-controllable thermometer BT22WP

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 2

Information about the device................................................ 4

Transport and storage........................................................... 5

Operation ............................................................................... 5

Maintenance and repair ...................................................... 12

Errors and faults.................................................................. 12

Disposal ............................................................................... 13

Declaration of conformity ................................................... 13

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

BT22WP

https://hub.trotec.com/?id=44698

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future
reference.

Do not use the device in potentially explosive rooms or
areas and do not install it there.

Do not use the device in aggressive atmosphere.

Protect the device from permanent direct sunlight.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Do not open the device.

Never charge batteries that cannot be recharged.

Different types of batteries and new and used batteries
must not be used together.

Insert the batteries into the battery compartment according
to the correct polarity.

Remove discharged batteries from the device. Batteries
contain materials hazardous to the environment. Dispose
of the batteries according to the national regulations.

Remove the batteries from the device if you will not be
using the device for a longer period of time.

Never short-circuit the supply terminal in the battery
compartment!

Do not swallow batteries! If a battery is swallowed, it can
cause severe internal burns within 2 hours! These burns
can lead to death!

If you think batteries might have been swallowed or
otherwise entered the body, seek medical attention
immediately!

Keep new and used batteries and an open battery
compartment away from children.

Summary of Contents for BT22WP

Page 1: ...TRT BA BT22WP TC211004TTRT03 002 EN BT22WP EN OPERATING MANUAL SMARTPHONE CONTROLLABLE THERMOMETER ...

Page 2: ... vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference Do not use the device in potentially explosive rooms or areas and do not install it there Do not use the device in aggressive atmosphere Protec...

Page 3: ...ple who use this device must have read and understood the operating manual especially the Safety chapter Safety signs and labels on the device Note Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition The following safety signs and labels are attached to the device Warning of magnetic field Information marked with this sym...

Page 4: ...be displayed and saved on the terminal device either numerically or in form of a chart Then the measurement data can be sent in PDF or Excel format The app also includes a report generation function an organiser function one for customer management and further analysis options Moreover it is possible to share measurements and project data with colleagues in another subsidiary If MultiMeasure Studi...

Page 5: ...d protect the device from external influences e g by using a suitable bag Storage When the device is not being used observe the following storage conditions dry and protected from frost and heat protected from dust and direct sunlight the storage temperature complies with the values specified in the Technical data Remove the batteries from the device Operation Inserting the batteries Note Make sur...

Page 6: ...n your terminal device is activated 1 Start the Trotec MultiMeasure Mobile app on the terminal device 2 Briefly actuate the On off measurement button 3 three times to switch on the appSensor ð The LED 2 flashes yellow 3 Press the Sensors button 6 on the terminal device ð The sensors overview opens 4 Press the Refresh button 7 ð If the scanning mode was not active before the colour of the Refresh b...

Page 7: ...meric temperature display Indicates minimum maximum and average value as well as the current value 11 Menu button Opens the menu to adjust the settings of the current measurement Info The indicated measured values will not be saved automatically Info By tapping on the graphic display 9 you can switch over to the numeric display and vice versa Measurement settings Proceed as follows to adjust the s...

Page 8: ...d on the terminal device 2 You can also press the On off measurement button 3 on the appSensor ð The appSensor determines the current measured value which is then displayed on the terminal device Recording measured values Proceed as follows to record measured values for later evaluation 1 Press the Menu button 11 or the free area below the measured value display ð The context menu for sensors open...

Page 9: ...ds the recorded measured values 24 Continue button Resumes the recording of the measured values without saving Analysing measurements Proceed as follows to call up the saved measurements 1 Press the Measurements button 25 ð An overview of already saved measurements will be displayed 2 Press the Display measurement button 27 for the desired measurement to be indicated ð A context menu for the selec...

Page 10: ...to the already saved measurement to be sure but if you save the measurement again with a different name these parameters will be added to the initial measurement Generating a report The reports generated in the MultiMeasure Mobile app are short reports providing a fast and simple documentation Proceed as follows to generate a new report 1 Press the Reports button 35 ð The reports overview opens 2 ...

Page 11: ...put mask opens in which you can view and edit all the information for the selected customer as well as directly start a new measurement ð The New customer button 39 changes In this menu it can be used to delete the selected customer data record Customers 40 Test customer_A1 Test customer_A2 Sensors Measurements Reports Customers Settings App settings Proceed as follows to make settings in the Trot...

Page 12: ... Repair Do not modify the device or install any spare parts For repairs or device testing contact the manufacturer Errors and faults The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list Bluetooth connection is terminated or interrupted Check whether the LED at the appSensor flashes gree...

Page 13: ... Council of 6 September 2006 on batteries and accumulators Please dispose of batteries and accumulators according to the relevant legal requirements Only for United Kingdom According to Waste Electrical and Electronic Equipment Regulations 2013 2013 3113 and the Waste Batteries and Accumulators Regulations 2009 2009 890 devices that are no longer usable must be collected separately and disposed of...

Page 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...