vane anemometer controlled via smartphone BA16WP

MultiMeasure Mobile app

Install the Trotec MultiMeasure Mobile app on the terminal
device you want to use in combination with the appSensor.

Info

Some of the app's functions require access to your
location and an active Internet connection.

The app is available for download in the Google Play Store as
well as in Apple's app store and via the following link:

https://hub.trotec.com/?id=43340

Start-up

Info

Allow for an acclimatization period of about 10 minutes
in the respective measuring environment prior to the
appSensor's measuring operation.

Proceed as follows to start up the appSensor:

1. Remove the protective cap from the device.

ð

The air circulates freely around the measuring sensor
ensuring precise measurements.

BA16WP

BA16WP

BA16WP

I.

II.

Connecting the appSensor

Info

The app can simultaneously be connected to several
different appSensors or appSensors of the same type
and also record several measurements at the same
time.

Proceed as follows to connect the appSensor to the terminal
device:

ü

The Trotec MultiMeasure Mobile app is installed.

ü

The Bluetooth function on your terminal device is activated.

1. Start the Trotec MultiMeasure Mobile app on the terminal

device.

2. Briefly actuate the 

On / off / measurement

 button (3) three

times to switch on the appSensor.

ð

The LED (2) flashes yellow.

3. Press the 

SENSORS

 button (6) on the terminal device.

ð

The sensors overview opens.

4. Press the 

Refresh

 button (7).

ð

If the scanning mode was not active before, the colour
of the 

Refresh

 button (7) will change from grey to black.

The terminal device now scans the surroundings for all
available appSensors.

5. Press the 

Connect

 button (8) to connect the desired sensor

to the terminal device.

ð

The LED (2) flashes green.

ð

The appSensor is connected to the terminal device and
starts measuring.

ð

The on-screen display changes to the continuous
measurement.

Sensors

BC21WP

BA16WP

BM22WP

BM31WP

BP21WP

BA30WP

Sensors

MEASUREMEN

TS

Reports

CUSTOMERS

SETTINGS

Connect

Active sensors nearby

Available sensors

8

7

6

No. Designation

Meaning

6

SENSORS

 button

Opens the sensors overview.

7

Refresh

 button

Refreshes the list of sensors near the
terminal device.

8

Connect

 button

Connects the displayed sensor to the
terminal device.

Summary of Contents for BA16WP

Page 1: ...TRT BA BA16WP TC2019 16 001 EN BA16WP EN OPERATING MANUAL VANE ANEMOMETER CONTROLLED VIA SMARTPHONE...

Page 2: ...he device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may r...

Page 3: ...ve a minimum distance of 20 cm between the pacemaker and the device Also do not use the device near automatically controlled systems such as alarm systems and automatic doors Radio waves may interfere...

Page 4: ...n use report templates and ready made text blocks for various fields of application to turn the data into professional reports Device depiction BA16WP 1 2 3 4 5 No Designation 1 Measuring sensor 2 LED...

Page 5: ...protected from frost and heat protected from dust and direct sunlight The storage temperature is the same as the range given in the Technical data chapter Remove the batteries from the device Operati...

Page 6: ...e appSensor to the terminal device The Trotec MultiMeasure Mobile app is installed The Bluetooth function on your terminal device is activated 1 Start the Trotec MultiMeasure Mobile app on the termina...

Page 7: ...of time Temperature indication as graphic display Indicates the temperature as measured over the course of time Volumetric flow indication as graphic display Indicates the volumetric flow as calculate...

Page 8: ...measurement button 13 to switch from continuous measurement to individual value measurement Individual value measurement has been selected as measuring mode Return to the screen displaying the measur...

Page 9: ...Relative humidity 24 7 25 4 25 37 6 58 40 37 6 RH 25 3 C Stop recording m s m s BA16WP No Designation Meaning 20 REC button Opens the sensor settings menu 21 Stop recording button Stops the current re...

Page 10: ...nsors MEASUREMEN TS Reports CUSTOMERS SETTINGS test_a1 Basic data Evaluations Evaluation parameters Values Generate table Generate graphic 29 30 31 32 33 34 No Designation Meaning 29 Basic data button...

Page 11: ...Press the corresponding button 37 to display the desired report An input mask opens in which you can view and edit all the information Sensors MEASUREMEN TS Reports CUSTOMERS SETTINGS Reports 03 26 20...

Page 12: ...pair Do not modify the device or install any spare parts For repairs or device testing contact the manufacturer Errors and faults The device has been checked for proper functioning several times durin...

Page 13: ...our website www trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prev...

Page 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: