vane anemometer controlled via smartphone BA16WP

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 2

Information about the device................................................ 4

Transport and storage........................................................... 5

Operation ............................................................................... 5

Maintenance and repair ...................................................... 12

Errors and faults.................................................................. 12

Disposal ............................................................................... 13

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information 
(e.g. material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

BA16WP

https://hub.trotec.com/?id=43340

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Do not immerse the device in water. Do not allow liquids to
penetrate into the device.

The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.

Protect the device from permanent direct sunlight.

Do not expose the device to strong vibrations.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Do not open the device.

Observe the storage and operating conditions as given in
the Technical data chapter.

Summary of Contents for BA16WP

Page 1: ...TRT BA BA16WP TC2019 16 001 EN BA16WP EN OPERATING MANUAL VANE ANEMOMETER CONTROLLED VIA SMARTPHONE...

Page 2: ...he device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may r...

Page 3: ...ve a minimum distance of 20 cm between the pacemaker and the device Also do not use the device near automatically controlled systems such as alarm systems and automatic doors Radio waves may interfere...

Page 4: ...n use report templates and ready made text blocks for various fields of application to turn the data into professional reports Device depiction BA16WP 1 2 3 4 5 No Designation 1 Measuring sensor 2 LED...

Page 5: ...protected from frost and heat protected from dust and direct sunlight The storage temperature is the same as the range given in the Technical data chapter Remove the batteries from the device Operati...

Page 6: ...e appSensor to the terminal device The Trotec MultiMeasure Mobile app is installed The Bluetooth function on your terminal device is activated 1 Start the Trotec MultiMeasure Mobile app on the termina...

Page 7: ...of time Temperature indication as graphic display Indicates the temperature as measured over the course of time Volumetric flow indication as graphic display Indicates the volumetric flow as calculate...

Page 8: ...measurement button 13 to switch from continuous measurement to individual value measurement Individual value measurement has been selected as measuring mode Return to the screen displaying the measur...

Page 9: ...Relative humidity 24 7 25 4 25 37 6 58 40 37 6 RH 25 3 C Stop recording m s m s BA16WP No Designation Meaning 20 REC button Opens the sensor settings menu 21 Stop recording button Stops the current re...

Page 10: ...nsors MEASUREMEN TS Reports CUSTOMERS SETTINGS test_a1 Basic data Evaluations Evaluation parameters Values Generate table Generate graphic 29 30 31 32 33 34 No Designation Meaning 29 Basic data button...

Page 11: ...Press the corresponding button 37 to display the desired report An input mask opens in which you can view and edit all the information Sensors MEASUREMEN TS Reports CUSTOMERS SETTINGS Reports 03 26 20...

Page 12: ...pair Do not modify the device or install any spare parts For repairs or device testing contact the manufacturer Errors and faults The device has been checked for proper functioning several times durin...

Page 13: ...our website www trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prev...

Page 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...