6. Take the SecoSan
®
Stick out of the water tank (1).
7. Thoroughly rinse the water tank with household vinegar
(descaling agent).
8. Thoroughly rinse the water tank and the SecoSan
®
Stick
with clear water.
9. Allow the water tank to dry.
10. Clean the inside of the bottom section and the mist nozzle
with household vinegar (descaling agent) and then use a
lint-free cloth to wipe the parts dry.
For cleaning the nebulizer membrane, see chapter
Cleaning the nebulizer membrane.
11. Insert the SecoSan
®
Stick into the water tank (1).
12. Fill the water tank with fresh drinking water.
13. If required, screw the filter cartridge with water
softener (8) onto the lid (15).
14. Screw the lid (15) firmly back onto the water tank (2).
8
15. Refit the mist nozzle (14) onto the water tank (2).
14
16. Refit the water tank (2) into the device.
In doing so, make sure that the arrow points to the front.
Please note that after inserting the water tank, the water
starts to run into the inside of the device immediately.
Cleaning the nebulizer membrane
Depending on the hardness of the drinking water used, deposits
may form on the nebulizer membrane over time. These could
affect the nebulizer performance. Therefore, the nebulizer
membrane should be cleaned on a regular basis.
To do so, please proceed as follows:
1. Remove the water tank (2) and the mist nozzle (14) as
described in
Cleaning the water tank
.
2. Remove any residual water from the inside of the device.
3. Wet the nebulizer membrane (9) with household
vinegar (descaling agent).
4. Let the descaling agent act for approx. 2 to 5 min.