3. Carefully clean the sensor lens (
5
) with a cotton bud
slightly moistened with water. Do not use too much water
as this could damage the sensor.
5
4. Carefully dry the lens with a dry cotton bud.
5. Then close the sensor cover again.
Activities required after maintenance
If you want to continue using the device:
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Storage chapter.
Technical annex
Technical data
Parameter
Value
Model
AirgoClean
®
150 E
Air flow rate with HEPA carbon
filter
Fan stage 1 = low
Fan stage 2 = mid
Fan stage 3 = high
Fan stage 4 = turbo
149 m
3
/h
278 m
3
/h
341 m
3
/h
355 m
3
/h
Ambient temperature
-10 °C to 45 °C
Operating range
0 % to 90 % RH
Mains connection (adapter)
220-240V V~ 50-60 Hz
Power input
32 W
Sound pressure level
52 dB(A)
Nominal current
0.1 A
Dimensions (length x width x
height)
387 x 247 x 571 mm
Minimum distance to walls and
other objects
A: top
B: rear
C: side
D: front
30 cm
30 cm
30 cm
30 cm
Weight
7 kg
Disposal
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website https://de.trotec.com/shop/.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.