background image

12

EN

air cleaner AirgoClean® 150 E

3. Carefully clean the sensor lens (

5

) with a cotton bud

slightly moistened with water. Do not use too much water
as this could damage the sensor.

5

4. Carefully dry the lens with a dry cotton bud.
5. Then close the sensor cover again.

Activities required after maintenance

If you want to continue using the device:

Reconnect the device to the mains.

If you do not intend to use the device for a considerable time:

Store the device according to the Storage chapter.

Technical annex

Technical data

Parameter

Value

Model

AirgoClean

®

 150 E

Air flow rate with HEPA carbon
filter
Fan stage 1 = low
Fan stage 2 = mid
Fan stage 3 = high
Fan stage 4 = turbo

149 m

3

/h

278 m

3

/h

341 m

3

/h

355 m

3

/h

Ambient temperature

-10 °C to 45 °C

Operating range

0 % to 90 % RH

Mains connection (adapter)

220-240V V~ 50-60 Hz

Power input

32 W

Sound pressure level

52 dB(A)

Nominal current

0.1 A

Dimensions (length x width x
height)

387 x 247 x 571 mm

Minimum distance to walls and
other objects

A: top

B: rear

C: side

D: front

30 cm
30 cm
30 cm
30 cm

Weight

7 kg

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website https://de.trotec.com/shop/.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

Summary of Contents for AIRGOCLEAN 150 E

Page 1: ...TRT BA AIRGOCLEAN 150E TC2020 52 002 EN AIRGOCLEAN 150 E EN OPERATING MANUAL AIR CLEANER ...

Page 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental...

Page 3: ...ose of replaced filters properly especially after filtering substances hazardous to health Never use the device as storage place or footstep Never select automatic mode if the device is used for virus filtration Intended use Use the device for cleaning the air in interior spaces only whilst adhering to the technical data and safety instructions Improper use Do not place the device on wet or floode...

Page 4: ...pollen dust mite residue mould fungus spores and other allergens from the air The integrated prefilter made of synthetic fibre filters out large dust particles before the air flows into the HEPA filter The integrated carbon filter with activated carbon also removes odours from the air The HEPA carbon filter is effective against house dust pet allergens cigarette smoke smog and particles which can ...

Page 5: ...ove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up The HEPA carbon filter is pre installed Note Remove the plastic cover from the HEPA carbon filter To do so please proceed as described in the chapter Changing the HEPA carbon filter When positioning the device observe the minimum distance from walls...

Page 6: ...n 1 h 2 h 4 h 8 h 20 Speed LED Indication of the selected fan speed Stage 1 low Stage 2 mid Stage 3 high Stage 4 turbo 21 Speed button Setting the fan speed in 4 stages 22 On Off button Switching the device on and off Switching the device on Once you have completely installed the device as described in the Start up chapter you can switch it on When the power cable has been connected the control pa...

Page 7: ...matic switch off function after a preset number of hours by means of the timer The number of hours can be set to 1 h 2 h 4 h or 8 h Automatic switch off ü The device is switched on 1 Press the timer button 19 until the desired number of hours is shown on the hours LED 18 ð The timer setting equals the desired number of hours ð The device switches off automatically after the set number of hours has...

Page 8: ...ired clean or replace the prefilter with integrated HEPA carbon filter The filter LED 11 is illuminated Clean or replace the prefilter with integrated HEPA carbon filter see chapter Operation and chapter maintenance The air outlet is obstructed Make sure that the air outlet is not blocked Remove any loose objects from the air outlet The HEPA carbon filter s plastic cover was not removed before ins...

Page 9: ...ent screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the filter for dirt and foreign objects and clean or replace if necessary Replacing the prefilter w...

Page 10: ...um cleaner 5 Put the air filter back in Cleaning and replacing the prefilter with integrated HEPA carbon filter Note Do not operate the device without an inserted prefilter with integrated HEPA carbon filter Note The HEPA carbon filter is not washable Only the integrated prefilter may be cleaned Do not use water or liquid cleaning agents to clean the 3 1 filter Note The lifetime of the prefilter w...

Page 11: ...to be used remove it from the plastic cover 5 Reinsert the prefilter with integrated HEPA carbon filter 23 into the device Make sure that the strips 24 of the filter are positioned on the outside 23 24 6 Put the air inlet 6 back on the device 6 7 Press the ION button 13 for two seconds to reset the Filter LED 11 Cleaning the air quality sensor The air quality sensor 5 has to be cleaned once it is ...

Page 12: ...put 32 W Sound pressure level 52 dB A Nominal current 0 1 A Dimensions length x width x height 387 x 247 x 571 mm Minimum distance to walls and other objects A top B rear C side D front 30 cm 30 cm 30 cm 30 cm Weight 7 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at th...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: