background image

8

EN

air cleaner AirgoClean® 150 E

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Switch off the device by pressing the 

On/Off

 button (

22

).

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Clean the device according to the Maintenance chapter.

Store the device according to the Storage chapter.

Available accessories

Warning

Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.

Designation

Article number

HEPA carbon filter, filter
efficiency 99.97 %

7.160.000.525

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damage.

Check the on-site fusing.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

Check the air inlet (

6

) and air outlet (

2

) for proper fit.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

Check the device cover for proper fit.

The device gets very warm, is loud or is losing
performance:

Check the air inlets and air filters for dirt. Remove external
dirt.

The device works with reduced capacity:

Check the prefilter with integrated HEPA carbon filter for
dirt. If required, clean or replace the prefilter with
integrated HEPA carbon filter.

The 

filter

 LED (

11

) is illuminated. Clean or replace the

prefilter with integrated HEPA carbon filter (see chapter
Operation and chapter maintenance).

The air outlet is obstructed. Make sure that the air outlet is
not blocked. Remove any loose objects from the air outlet.

The HEPA carbon filter's plastic cover was not removed
before installation. Take the HEPA carbon filter out of the
plastic cover.

The device works with no capacity or the air quality does
not improve:

Check whether any windows and/or doors of the room are
open. If so, close them.

The HEPA carbon filter is not installed. Install the HEPA
carbon filter.

Check the minimum distance to walls or other objects.
Position the device a little more in the room's centre if
required.

The 

air quality

 LED is illuminated in red for a longer period

of time:

Check the c air quality in the room. The air in the room
may be heavily contaminated. Wait for a few minutes to
see whether the colour of the 

air quality

 LED changes.

The air quality sensor is clogged or soiled. Windows and
doors should be closed, otherwise dust and other
contamination is able to enter the room. Clean the air
quality sensor as described in the Maintenance chapter.

The device gives off an unpleasant odour:

Check the HEPA carbon filter for dirt. If necessary, clean or
replace the HEPA carbon filter.

Smoke, e.g. dense tobacco smoke, odours and
contaminations may be in the air. Ventilate the room.

The 

filter

 LED (

11

) is illuminated:

Clean or replace the prefilter with integrated HEPA carbon
filter (

23

).

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.

Summary of Contents for AIRGOCLEAN 150 E

Page 1: ...TRT BA AIRGOCLEAN 150E TC2020 52 002 EN AIRGOCLEAN 150 E EN OPERATING MANUAL AIR CLEANER ...

Page 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental...

Page 3: ...ose of replaced filters properly especially after filtering substances hazardous to health Never use the device as storage place or footstep Never select automatic mode if the device is used for virus filtration Intended use Use the device for cleaning the air in interior spaces only whilst adhering to the technical data and safety instructions Improper use Do not place the device on wet or floode...

Page 4: ...pollen dust mite residue mould fungus spores and other allergens from the air The integrated prefilter made of synthetic fibre filters out large dust particles before the air flows into the HEPA filter The integrated carbon filter with activated carbon also removes odours from the air The HEPA carbon filter is effective against house dust pet allergens cigarette smoke smog and particles which can ...

Page 5: ...ove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up The HEPA carbon filter is pre installed Note Remove the plastic cover from the HEPA carbon filter To do so please proceed as described in the chapter Changing the HEPA carbon filter When positioning the device observe the minimum distance from walls...

Page 6: ...n 1 h 2 h 4 h 8 h 20 Speed LED Indication of the selected fan speed Stage 1 low Stage 2 mid Stage 3 high Stage 4 turbo 21 Speed button Setting the fan speed in 4 stages 22 On Off button Switching the device on and off Switching the device on Once you have completely installed the device as described in the Start up chapter you can switch it on When the power cable has been connected the control pa...

Page 7: ...matic switch off function after a preset number of hours by means of the timer The number of hours can be set to 1 h 2 h 4 h or 8 h Automatic switch off ü The device is switched on 1 Press the timer button 19 until the desired number of hours is shown on the hours LED 18 ð The timer setting equals the desired number of hours ð The device switches off automatically after the set number of hours has...

Page 8: ...ired clean or replace the prefilter with integrated HEPA carbon filter The filter LED 11 is illuminated Clean or replace the prefilter with integrated HEPA carbon filter see chapter Operation and chapter maintenance The air outlet is obstructed Make sure that the air outlet is not blocked Remove any loose objects from the air outlet The HEPA carbon filter s plastic cover was not removed before ins...

Page 9: ...ent screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the filter for dirt and foreign objects and clean or replace if necessary Replacing the prefilter w...

Page 10: ...um cleaner 5 Put the air filter back in Cleaning and replacing the prefilter with integrated HEPA carbon filter Note Do not operate the device without an inserted prefilter with integrated HEPA carbon filter Note The HEPA carbon filter is not washable Only the integrated prefilter may be cleaned Do not use water or liquid cleaning agents to clean the 3 1 filter Note The lifetime of the prefilter w...

Page 11: ...to be used remove it from the plastic cover 5 Reinsert the prefilter with integrated HEPA carbon filter 23 into the device Make sure that the strips 24 of the filter are positioned on the outside 23 24 6 Put the air inlet 6 back on the device 6 7 Press the ION button 13 for two seconds to reset the Filter LED 11 Cleaning the air quality sensor The air quality sensor 5 has to be cleaned once it is ...

Page 12: ...put 32 W Sound pressure level 52 dB A Nominal current 0 1 A Dimensions length x width x height 387 x 247 x 571 mm Minimum distance to walls and other objects A top B rear C side D front 30 cm 30 cm 30 cm 30 cm Weight 7 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at th...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: