background image

EN

9

air cleaner AirgoClean® 11 E

Available accessories

Warning

Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.

Designation

Article number

HEPA carbon filter, filter
efficiency 99.97 %

7.160.000.511

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damage.

Check the on-site fusing.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

The device gets very warm, is loud or is losing
performance:

Check the air inlets and air filters for dirt. Remove external
dirt.

The device works with reduced capacity:

Check the HEPA carbon filter for dirt. If necessary, clean or
replace the HEPA carbon filter.

The air outlet is obstructed. Make sure that the air outlet is
not blocked. Remove any loose objects from the air outlet.

The HEPA carbon filter's plastic cover was not removed
before installation. Take the HEPA carbon filter out of the
plastic cover.

The device works with no capacity or the air quality does
not improve:

Check whether any windows and/or doors of the room are
open. If so, close them.

The HEPA carbon filter is not installed. Install the HEPA
carbon filter.

Check the minimum distance to walls or other objects.
Position the device a little more in the room's centre if
required.

The 

air quality

 LED is illuminated in red for a longer period

of time:

Check the c air quality in the room. The air in the room
may be heavily contaminated. Wait for a few minutes to
see whether the colour of the 

air quality

 LED changes.

The air quality sensor is clogged or soiled. Windows and
doors should be closed, otherwise dust and other
contamination is able to enter the room. Clean the air
quality sensor as described in the Maintenance chapter.

The device gives off an unpleasant odour:

Check the HEPA carbon filter for dirt. If necessary, clean or
replace the HEPA carbon filter.

Smoke, e.g. dense tobacco smoke, odours and
contaminations may be in the air. Ventilate the room.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.

Summary of Contents for AIRGOCLEAN 11 E

Page 1: ...TRT BA AIRGOCLEAN 11E TC2020 47 002 EN AIRGOCLEAN 11 E EN OPERATING MANUAL AIR CLEANER ...

Page 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental...

Page 3: ...s or dirt located in the immediate surroundings of air inlet and air outlet Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Do not expose the device to heat or direct sunlight Make sure that the suction side is kept free of dirt and loose objects Dispose of replaced filters properly especially after filtering substanc...

Page 4: ...tion about the device Device description The device serves to filter the room air with the aim of reducing slight and medium contaminations and odours in order to improve the air quality It is equipped with a powerful fan sucking in the air at the front The air flows through the filter and is cleaned Afterwards the fan releases the clean air back into the room The 3 in 1 filter is composed of a HE...

Page 5: ... storage of the device Transport Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power cable out of the mains socket After transporting the device observe the following Set up the device in an upright position after transport Storage When the device is not being used observe the following storage conditions Dry and protected fro...

Page 6: ...restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Only put up the device in an upright stable position on firm ground Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cabl...

Page 7: ...D Is illuminated according to the air quality green good blue medium red poor Switching the device on Once you have completely installed the device as described in the Start up chapter you can switch it on Afterwards only the on off key 11 lights up and the device is in standby mode 1 Press the on off 11 button to switch the device on ð The fan speed LED 14 lights up Before initial start up the de...

Page 8: ...ours by means of the timer The number of hours can be set to 1 h 2 h 4 h or 8 h Automatic switch off ü The device is switched on 1 Press the timer button 12 until the desired number of hours is shown on the hours LED 13 ð The timer setting equals the desired number of hours ð The device switches off automatically after the set number of hours has elapsed Note regarding automatic switch off Pressin...

Page 9: ...utlet is not blocked Remove any loose objects from the air outlet The HEPA carbon filter s plastic cover was not removed before installation Take the HEPA carbon filter out of the plastic cover The device works with no capacity or the air quality does not improve Check whether any windows and or doors of the room are open If so close them The HEPA carbon filter is not installed Install the HEPA ca...

Page 10: ...achment screws X X Test run X Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the filter for dirt and foreign objects and clean or replace if necessary Replace the HEPA carbon filter Cleaning the ai...

Page 11: ...ce for dirt 4 If you see a thick layer of dust clean the inside of the device with a vacuum cleaner 5 Put the air filter back in Changing the HEPA carbon filter Note Do not operate the device without a HEPA carbon filter inserted Note The HEPA carbon filter is not washable Do not use water or liquid cleaning agents to clean the HEPA carbon filter The HEPA carbon filter has to be replaced as soon a...

Page 12: ...EPA carbon filter 17 into the device 17 6 Reassemble the bottom plate 16 and the device by turning the bottom plate in the Close direction of the arrow Make sure that the two arrows of the marking 18 are positioned exactly on top of each other 16 18 Proceed as follows to reset the filter change LED 6 ü The device is now in standby mode 1 Press the fan speed button 9 for more than 2 seconds 2 Press...

Page 13: ... RH Mains connection adapter 100 240 V 50 60 Hz Power consumption 11 W Nominal current 1 0 A Dimensions length x width x height 238 x 238 x 335 mm Minimum distance to walls and other objects A top B rear C side D front 30 cm 30 cm 30 cm 30 cm Weight 2 5 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be dispose...

Page 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: