background image

EN

13

air cleaner AirgoClean® 11 E

Cleaning the air quality sensor

The air quality sensor (4) has to be cleaned once it is soiled and
if the 

air quality

 LED (14) is illuminated in red for a longer period

of time (please also refer to the chapter Operation and the
chapter Errors and faults).

1. Clean the sensor using a soft, lint-free cloth. Do not use

water to clean the sensor as it could damage it.

4

Activities required after maintenance

If you want to continue using the device:

Reconnect the device to the mains.

If you do not intend to use the device for a considerable time:

Store the device according to the Storage chapter.

Technical annex

Technical data

Parameter

Value

Model

AirgoClean

®

 11 E

Air flow rate with HEPA carbon
filter
Fan stage 

I

Fan stage 

II

Fan stage 

III

42 m

3

/h

72 m

3

/h

120 m

3

/h

Ambient temperature

5 °C to 40 °C

Operating range

30 % to 90 % RH

Mains connection (adapter)

100-240 V~ 50-60 Hz

Power consumption

11 W

Nominal current

1.0 A

Dimensions (length x width x
height)

238 x 238 x 335 mm

Minimum distance to walls and
other objects

A: top

B: rear

C: side

D: front

30 cm
30 cm
30 cm
30 cm

Weight

2.5 kg

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website https://de.trotec.com/shop/.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

Summary of Contents for AIRGOCLEAN 11 E

Page 1: ...TRT BA AIRGOCLEAN 11E TC2020 47 002 EN AIRGOCLEAN 11 E EN OPERATING MANUAL AIR CLEANER ...

Page 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental...

Page 3: ...s or dirt located in the immediate surroundings of air inlet and air outlet Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Do not expose the device to heat or direct sunlight Make sure that the suction side is kept free of dirt and loose objects Dispose of replaced filters properly especially after filtering substanc...

Page 4: ...tion about the device Device description The device serves to filter the room air with the aim of reducing slight and medium contaminations and odours in order to improve the air quality It is equipped with a powerful fan sucking in the air at the front The air flows through the filter and is cleaned Afterwards the fan releases the clean air back into the room The 3 in 1 filter is composed of a HE...

Page 5: ... storage of the device Transport Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power cable out of the mains socket After transporting the device observe the following Set up the device in an upright position after transport Storage When the device is not being used observe the following storage conditions Dry and protected fro...

Page 6: ...restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Only put up the device in an upright stable position on firm ground Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cabl...

Page 7: ...D Is illuminated according to the air quality green good blue medium red poor Switching the device on Once you have completely installed the device as described in the Start up chapter you can switch it on Afterwards only the on off key 11 lights up and the device is in standby mode 1 Press the on off 11 button to switch the device on ð The fan speed LED 14 lights up Before initial start up the de...

Page 8: ...ours by means of the timer The number of hours can be set to 1 h 2 h 4 h or 8 h Automatic switch off ü The device is switched on 1 Press the timer button 12 until the desired number of hours is shown on the hours LED 13 ð The timer setting equals the desired number of hours ð The device switches off automatically after the set number of hours has elapsed Note regarding automatic switch off Pressin...

Page 9: ...utlet is not blocked Remove any loose objects from the air outlet The HEPA carbon filter s plastic cover was not removed before installation Take the HEPA carbon filter out of the plastic cover The device works with no capacity or the air quality does not improve Check whether any windows and or doors of the room are open If so close them The HEPA carbon filter is not installed Install the HEPA ca...

Page 10: ...achment screws X X Test run X Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the filter for dirt and foreign objects and clean or replace if necessary Replace the HEPA carbon filter Cleaning the ai...

Page 11: ...ce for dirt 4 If you see a thick layer of dust clean the inside of the device with a vacuum cleaner 5 Put the air filter back in Changing the HEPA carbon filter Note Do not operate the device without a HEPA carbon filter inserted Note The HEPA carbon filter is not washable Do not use water or liquid cleaning agents to clean the HEPA carbon filter The HEPA carbon filter has to be replaced as soon a...

Page 12: ...EPA carbon filter 17 into the device 17 6 Reassemble the bottom plate 16 and the device by turning the bottom plate in the Close direction of the arrow Make sure that the two arrows of the marking 18 are positioned exactly on top of each other 16 18 Proceed as follows to reset the filter change LED 6 ü The device is now in standby mode 1 Press the fan speed button 9 for more than 2 seconds 2 Press...

Page 13: ... RH Mains connection adapter 100 240 V 50 60 Hz Power consumption 11 W Nominal current 1 0 A Dimensions length x width x height 238 x 238 x 335 mm Minimum distance to walls and other objects A top B rear C side D front 30 cm 30 cm 30 cm 30 cm Weight 2 5 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be dispose...

Page 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: