background image

8

EN

oil-filled radiator TRH 25 E / TRH 26 E

7. Turn the device over and set it down on the castors. If

necessary, use a spirit level to check the correct
positioning. Adjust the screw connection if required.

Start-up

Info

Odours might arise upon initial start-up or after a
longer period of non-use.

When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical annex.

A

B

C

C

D

Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.

The device may only be operated when fully assembled
and set up in a vertical position on a stable surface.
Operation on instable ground is prohibited.

Set the device up in an upright and stable position.

Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.

Make sure that extension cables are completely unrolled.

Make sure that no curtains or other objects interfere with
the air flow.

Do not position the device directly below a wall socket.

Make sure that the device cannot come into contact with
moisture or water.

Prior to initial start-up, insert batteries in the remote control.

Connecting the power cable

Insert the mains plug into a properly fused mains socket.

Make sure that the power cable is guided along the back
of the device. Never guide the power cable along the front
of the device!

Operation

Avoid open doors and windows.

Operating elements TRH 25 E / TRH 26 E

7

8

9

10

11

12

13

14

15

16

17

18

Remote control

All settings of the device can also be made using the remote
control included in the scope of delivery. 
Insert suitable batteries in the remote control (see chapter
Technical annex).

12

14

10
13
11

Summary of Contents for 1410000720

Page 1: ...TRT BA TRH25E TRH26E TC210830TTRT01 004 EN TRH 25 E TRH 26 E EN OPERATING MANUAL OIL FILLED RADIATOR EN This product is only suitable for well insulated spaces or occasional use ...

Page 2: ...s you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual and the EU declaration of conformity via the following link TRH 25 E https hub trotec com id 43933 TRH 26 E https hub trotec com id 43934 Safety Read this manual carefully before star...

Page 3: ...a properly fused mains socket Observe the device s power input cable length and intended use when selecting extensions to the power cable Completely unroll extension cables Avoid electrical overload Before carrying out maintenance care or repair work on the device remove the mains plug from the mains socket Hold onto the mains plug while doing so Switch the device off and disconnect the power cabl...

Page 4: ... on the device Symbols Meaning This symbol located on the device indicates that it is prohibited to place objects such as towels clothes etc above or directly in front of the device In order to avoid overheating and fire hazards the heater must not be covered Residual risks Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company ...

Page 5: ...right position is changed in any other manner The tilt protection switches the device off when it is inclined out of its vertical position The device can again be used as usual only a few seconds after placing it back in vertical position and on solid ground Information about the device Device description The oil filled radiator TRH 25 E TRH 26 E is used to generate warm air for interior spaces Th...

Page 6: ...ion where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Place no further devices or objects on top of the device to prevent it from being damaged Remove batteries from the remote control Assembly and start up Scope of delivery 1 x Oil filled radiator 2 x Mounting plate for castors 4 x Castor 4 x Cap nut 4 x Wing nut 2 x U bolt 1 x Remote c...

Page 7: ...ion the respective U bolt between either the first or the last two ribs at the device bottom 5 Attach the mounting plates with the castors to the U bolts In doing so observe the position of the cut outs at one side of the mounting plates They should be directed towards the device front control panel 6 Bolt the mounting plates wing nuts and U bolts together Ensure the tight fit of the mounting plat...

Page 8: ...ng hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled Make sure that no curtains or other objects interfere with the air flow Do not position the device directly below a wall socket Make sure that the device cannot come into contact with moisture or w...

Page 9: ...n acoustic signal is emitted ð The device is now in standby mode 2 Press the power button 12 ð The preset room temperature of 25 C is indicated on the segment display 18 ð The device starts in power level III ð The high power level lII symbol 15 is illuminated ð The Power symbol 9 is illuminated ð The Temperature symbol 7 is illuminated Info The device will not be switched on until the room temper...

Page 10: ...et or damp hands 1 Switch the device off 2 Hold onto the mains plug while pulling the power cable out of the mains socket 3 Allow the device to cool down sufficiently 4 Clean the device according to the Maintenance chapter 5 Store the device according to the Storage chapter Errors and faults Warning of electrical voltage Tasks which require the device to be opened must only be carried out by autho...

Page 11: ...not touch the mains plug with wet or damp hands Switch the device off Hold onto the mains plug while pulling the power cable out of the mains socket Allow the device to cool down completely Warning of electrical voltage Tasks which require the device to be opened must only be carried out by authorised specialist companies or by Trotec Note The device is filled with the heating medium oil Tasks whi...

Page 12: ...l with room and or outdoor temperature feedback NA NA Fan assisted heat output NA NA Type of heat output room temperature control Single stage heat output no room temperature control NO NO Two or more manually adjustable stages no room temperature control NO NO With mechanic thermostat room temperature control NO NO With electronic room temperature control YES YES With electronic room temperature ...

Page 13: ...sed for your country The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment In the European Union batteries and accumulators must not be trea...

Page 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...