oil-filled radiator TRH 25 E / TRH 26 E
Automatic switch-on
ü
The device is in standby mode.
1. Press the
Timer
button (13).
ð
The
Timer
symbol (8) is illuminated.
ð
The
Power
symbol (9) is illuminated.
ð
The number of hours 00 blinks on the segment
display (18).
2. Repeatedly press the
Timer
button (13) to select the
desired number of hours.
ð
The desired number of hours blinks on the segment
display (18) for approx. 7 s.
ð
The
Timer
symbol (8) is illuminated.
ð
The
Power
symbol (9) is illuminated.
ð
The desired number of hours is shown on the segment
display (18).
Notes regarding automatic switch-on:
•
Manually switching the device on disables the automatic
switch-on function.
•
Switching the device off by means of the on/off switch (6)
deactivates the automatic switch-on function.
•
If you select 00 hours, the timer will be off.
Automatic switch-off
ü
The device is switched on.
ü
The device runs at the set power level.
1. Press the
Timer
button (13).
ð
The
Timer
symbol (8) is illuminated.
ð
The
Power
symbol (9) is illuminated.
ð
The number of hours 00 blinks on the segment
display (18).
2. Repeatedly press the
Timer
button (13) to select the
desired number of hours.
ð
The desired number of hours blinks on the segment
display (18) for approx. 7 s.
ð
The
Timer
symbol (8) is illuminated.
ð
The
Power
symbol (9) is illuminated.
ð
The symbol for the power level set (15, 16, 17) is
illuminated.
ð
The temperature set is shown on the segment
display (18).
Notes regarding automatic switch-off:
•
Manually switching the device off disables the automatic
switch-off function.
•
If you select 00 hours, the timer will be off.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
1. Switch the device off.
2. Hold onto the mains plug while pulling the power cable out
of the mains socket.
3. Allow the device to cool down sufficiently.
4. Clean the device according to the Maintenance chapter.
5. Store the device according to the Storage chapter.
Errors and faults
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device makes noises after switch-on:
•
The heating medium oil expands due to heating. This is
what causes the noise. It is a perfectly normal process. No
measures are required.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage. If you
notice damages, do not try to take the device back into
operation.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
•
Check the on-site fusing.
•
Check the room temperature. The room thermostat may
have switched off, because the desired room temperature
has been reached.
•
Check whether the device is standing upright and on level
ground. The tilt protection may have been tripped owing to
the fact that the device was knocked over. Always put up
the device in an upright position on a suitable, sufficiently
dimensioned surface.
•
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
•
Check whether the overheating protection has tripped (see
chapter Safety).
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.