Trotec 1120000124 Original Instructions Manual Download Page 5

EN

5

dehumidifier TTK 125 S

Warning of electrical voltage

Risk of electric shock!
The device does not have the appropriate protection
class for use in wet rooms.
There is a risk of electric shock!
Never use the device in wet rooms (e.g. in laundry
rooms) and never immerse the device in water!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Note

Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.

Note

When operated with condensation tank, make sure that
the condensation tank is inserted correctly!
If the condensation tank is removed or not installed
correctly, the device does 

not

 switch off.

Behaviour in the event of an emergency

1. Switch the device off.
2. Disconnect the device from the mains feed-in: Hold onto

the mains plug while pulling the power cable out of the
mains socket.

3. Do not reconnect a defective device to the mains.

Information about the device

Device description

The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.

Device depiction

1

2

3

4

9

8
7

6

5

No.

Designation

1

Air inlet

2

Connection for optional condensate pump

3

Hose connector for condensation drain hose

4

Condensation tank

5

Wheels

6

Control panel

7

Air outlet

8

Carrying handle

9

Air filter

Summary of Contents for 1120000124

Page 1: ...TRT BA TTK125S TC220617TTRT03 010 EN TTK 125 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Page 2: ...ing the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions...

Page 3: ...arge the collected condensate before transport and storage Do not drink it Health hazard Only use original spare parts for otherwise safe and functional operation cannot be ensured Safety warnings for...

Page 4: ...t companies for cooling and air conditioning or by Trotec Safety signs and labels on the device Note Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers an...

Page 5: ...nt of an emergency 1 Switch the device off 2 Disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective...

Page 6: ...the device is not being used observe the following storage conditions Only store the device in a room measuring more than 4 m2 Only position the device in rooms where there is no source of ignition e...

Page 7: ...filter inserted into the air inlet Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the...

Page 8: ...8 EN dehumidifier TTK 125 S 1 2 3 4 5...

Page 9: ...y switch Selection of relative room humidity 13 Mains switch Switching the device on and off Is illuminated when the device is switched on 14 Condensation tank LED Illuminated when the condensation ta...

Page 10: ...operation mode the device dehumidifies the air constantly regardless of the humidity To start continuous operation mode set the rotary switch 12 to Max Automatic defrost If the room temperature is bel...

Page 11: ...e condensation tank if need be Clean the device according to the Maintenance chapter Store the device according to the Transport and storage chapter Available accessories Warning Only use accessories...

Page 12: ...ght position Condensate is leaking Check the device for leaks The compressor does not start Check the room temperature Observe the device s permissible operating range according to the technical data...

Page 13: ...nd or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and...

Page 14: ...onditioning or by Trotec Safety signs and labels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean t...

Page 15: ...lifetime If you remove the condensation tank from the device and reinsert it after emptying the compressor will switch back on with a delay of approx 3 min This delay is also enabled in optional hygro...

Page 16: ...Operating range relative humidity 50 90 RH Max permissible pressure 3 0 MPa Pressure suction side 0 6 MPa Pressure outlet side 2 1 MPa Air volume flow 250 m h Mains connection 220 240 V 50 Hz Power co...

Page 17: ...EN 17 dehumidifier TTK 125 S Wiring diagram With operating hours counter...

Page 18: ...18 EN dehumidifier TTK 125 S With operating hours counter and MID counter...

Page 19: ...EN 19 dehumidifier TTK 125 S Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions...

Page 20: ...socket 8 Water tank baseplate 25 Spinning castor with brake 42 Defrost sensor 9 Control s box 26 Spinning castor without brake 43 Compressor 10 Control s protection bars 27 Insulating plate 44 Finned...

Page 21: ...2013 3113 as amended devices that are no longer usable must be collected separately and disposed of in an environmentally friendly manner Declaration of conformity Declaration of conformity in accord...

Page 22: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: