Trotec 1120000124 Original Instructions Manual Download Page 21

EN

21

dehumidifier TTK 125 S

Disposal

Always dispose of packing materials in an environmentally
friendly manner and in accordance with the applicable local
disposal regulations.

The icon with the crossed-out waste bin on waste

electrical or electronic equipment is taken from 
Directive 2012/19/EU. It states that this device must not be
disposed of with the household waste at the end of its life. You
will find collection points for free return of waste electrical and
electronic equipment in your vicinity. The addresses can be
obtained from your municipality or local administration. You can
also find out about other return options that apply for many EU
countries on the website https://hub.trotec.com/?id=45090.
Otherwise, please contact an official recycling centre for
electronic and electrical equipment authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
Have the refrigerant (propane) disposed of appropriately and
according to the national regulations by a company with the
relevant certification (European Waste Catalogue 160504).

Only for United Kingdom

According to Waste Electrical and Electronic Equipment
Regulations 2013 (SI 2013/3113) (as amended) devices that are
no longer usable must be collected separately and disposed of
in an environmentally friendly manner.

Declaration of conformity

Declaration of conformity in accordance with the EC Machinery
Directive 2006/42/EC, Annex II, Part 1, Section A

We – Trotec GmbH – declare in sole responsibility that the
product designated below was developed, constructed and
produced in compliance with the requirements of the
EC Machinery Directive in the version 2006/42/EC.

Product model / Product:

TTK 125 S

Product type:

dehumidifier

Year of manufacture as of:

2022

Relevant EU directives:

2011/65/EU

2012/19/EU

2014/30/EU

2015/863/EU

Applied harmonised standards:

EN 60335-1:2012/A15:2021

EN 60335-2-40:2003

EN 60335-2-40:2003/A1:2006

EN 60335-2-40:2003/A2:2009

EN 60335-2-40:2003/A11:2004

EN 60335-2-40:2003/A12:2005

EN 60335-2-40:2003/A13:2012

EN 60335-2-40:2003/AC:2006

EN 60335-2-40:2003/AC:2010

EN 60335-2-40:2003/AC:2013

EN 61000-3-3:2013

Applied national standards and technical specifications:

EN IEC 55014-1:2021

EN IEC 55014-2:2021

IEC 60335-2-40:2018

EN IEC 61000-3-2:2019

EN IEC 61000-3-2:2019/A1:2021

EN 60335-1:2012/A1:2019

EN 60335-1:2012/A2:2019

EN 60335-1:2012/A14:2019

EN 61000-3-3:2013/A1:2019

IEC 60335-1:2010

IEC 60335-1:2010/A1:2013/A2:2016

IEC 61000-3-2:2018

IEC 61000-3-2:2018/A1:2020

IEC 61000-3-3:2013

IEC 61000-3-3:2013/A2:2021

Manufacturer and name of the authorised representative of
the technical documentation:

Trotec GmbH
Grebbener Straße 7, D-52525 Heinsberg
Phone: +49 2452 962-400
E-mail: [email protected]

Place and date of issue:
Heinsberg, 

16.09.2022

Joachim Ludwig, Managing Director

Summary of Contents for 1120000124

Page 1: ...TRT BA TTK125S TC220617TTRT03 010 EN TTK 125 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Page 2: ...ing the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions...

Page 3: ...arge the collected condensate before transport and storage Do not drink it Health hazard Only use original spare parts for otherwise safe and functional operation cannot be ensured Safety warnings for...

Page 4: ...t companies for cooling and air conditioning or by Trotec Safety signs and labels on the device Note Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers an...

Page 5: ...nt of an emergency 1 Switch the device off 2 Disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective...

Page 6: ...the device is not being used observe the following storage conditions Only store the device in a room measuring more than 4 m2 Only position the device in rooms where there is no source of ignition e...

Page 7: ...filter inserted into the air inlet Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the...

Page 8: ...8 EN dehumidifier TTK 125 S 1 2 3 4 5...

Page 9: ...y switch Selection of relative room humidity 13 Mains switch Switching the device on and off Is illuminated when the device is switched on 14 Condensation tank LED Illuminated when the condensation ta...

Page 10: ...operation mode the device dehumidifies the air constantly regardless of the humidity To start continuous operation mode set the rotary switch 12 to Max Automatic defrost If the room temperature is bel...

Page 11: ...e condensation tank if need be Clean the device according to the Maintenance chapter Store the device according to the Transport and storage chapter Available accessories Warning Only use accessories...

Page 12: ...ght position Condensate is leaking Check the device for leaks The compressor does not start Check the room temperature Observe the device s permissible operating range according to the technical data...

Page 13: ...nd or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and...

Page 14: ...onditioning or by Trotec Safety signs and labels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean t...

Page 15: ...lifetime If you remove the condensation tank from the device and reinsert it after emptying the compressor will switch back on with a delay of approx 3 min This delay is also enabled in optional hygro...

Page 16: ...Operating range relative humidity 50 90 RH Max permissible pressure 3 0 MPa Pressure suction side 0 6 MPa Pressure outlet side 2 1 MPa Air volume flow 250 m h Mains connection 220 240 V 50 Hz Power co...

Page 17: ...EN 17 dehumidifier TTK 125 S Wiring diagram With operating hours counter...

Page 18: ...18 EN dehumidifier TTK 125 S With operating hours counter and MID counter...

Page 19: ...EN 19 dehumidifier TTK 125 S Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions...

Page 20: ...socket 8 Water tank baseplate 25 Spinning castor with brake 42 Defrost sensor 9 Control s box 26 Spinning castor without brake 43 Compressor 10 Control s protection bars 27 Insulating plate 44 Finned...

Page 21: ...2013 3113 as amended devices that are no longer usable must be collected separately and disposed of in an environmentally friendly manner Declaration of conformity Declaration of conformity in accord...

Page 22: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...