10
EN
dehumidifier TTK 125 S
The device is optionally available with an operating element with
dual counter (see the image at the top right). The dual counter
registers both the operating hours and the energy consumption
and is certified according to the MID (Measuring Instruments
Directive 2004/22/EC). The kWh display is factory-calibrated
and may be used for accounting purposes. Contact your Trotec
customer service.
The
Status
LED (15) flashes once a second during normal
operation. If it flashes more frequently, lights up permanently or
does not light up at all, there might be a fault, see chapter
Errors and faults.
Condensate pump (optional)
The device can optionally be operated with a condensate pump
(see chapter Installing the condensate pump (optional)). Contact
your Trotec customer service.
16
No. Designation
Meaning
16
Condensate pump
button
Switching the condensate pump on
and off for draining residual water
Info
Note that the device is only functional after three to five
minutes each time it is switched on or after the water
container has been inserted.
Switching the device on
1. Ensure that the condensation tank is empty and inserted
correctly. Otherwise, the device will not operate!
2. Insert the mains plug into a properly secured mains
socket.
3. Switch on the device at the mains switch (13).
4. Ensure that the mains switch (13) is lit.
5. Check whether the
Condensation tank
LED (14) is out.
Otherwise, empty the condensation tank.
6. Adjust the room humidity level with the rotary switch (12).
Continuous operation mode
In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity. To start continuous
operation mode, set the rotary switch (12) to Max.
Automatic defrost
If the room temperature is below 11 °C, the evaporator will
freeze during dehumidification. The device will then carry out an
automatic defrost. The duration of the defrost process can vary.
•
Do not switch off the device during automatic defrost. Do
not remove the mains plug from the mains socket.
Temperature limitation (overheating protection)
The device comes with a temperature limitation. It serves to
protect e.g. the compressor from overheating.
•
Upper temperature limit: +35 °C +/- 2 °C
•
Lower temperature limit: -3 °C +/- 2 °C
If the ambient temperature exceeds or falls below these limits,
the device automatically switches off the compressor; only the
fan will keep running. This feature protects the device from
overloading since high temperatures and high humidity levels
expose the device to extreme stresses. Moreover, drying is no
longer economical at such high temperatures and also poses
dangers for the inventory of the room to be dried. Please note
that the switch-off function works with a switch-on hysteresis of
-2 °C.
Info
The compressor always starts with a delay. This
protects the compressor and thus increases its
lifetime. If you remove the condensation tank from the
device and reinsert it after emptying, the compressor
will switch back on with a delay of approx. 3 min. This
delay is also enabled in optional hygrostat operation. If
the room humidity exceeds the setting of the selection
switch, the compressor will only switch back on after a
delay.
The fan keeps running independently of the
compressor. The fan only switches off if the
condensation tank is removed.
Summary of Contents for 1120000124
Page 1: ...TRT BA TTK125S TC220617TTRT03 010 EN TTK 125 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...
Page 8: ...8 EN dehumidifier TTK 125 S 1 2 3 4 5...
Page 17: ...EN 17 dehumidifier TTK 125 S Wiring diagram With operating hours counter...
Page 18: ...18 EN dehumidifier TTK 125 S With operating hours counter and MID counter...