background image

EN

3

dehumidifier TTK 125 S

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Do not cover the device during operation.

Do not sit on the device.

This appliance is not a toy. Keep away from children and
animals.

Occasionally observe the device during operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The mains connection must correspond to the
specifications in the Technical annex.

Insert the mains plug into a properly fused mains socket.

Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.

Make sure that the air inlet and outlet are not obstructed.

Make sure that the suction side is kept free of dirt and
loose objects.

Never insert any objects or limbs into the device.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Only transport the device in an upright position with an
emptied condensation tank or drain hose.

Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!

Only use original spare parts, for otherwise safe and
functional operation cannot be ensured.

Safety warnings for devices containing flammable
refrigerants

Only position the device in rooms where potentially leaking
refrigerant cannot accumulate. Unventilated rooms, in
which the device is installed, operated or stored, must be
built in a way to ensure that potentially leaking refrigerant
cannot accumulate. This serves to avoid fire or explosion
hazards resulting from an ignition of the refrigerant by an
electric furnace, cooking stove or another ignition source.

Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).

Please note that the refrigerant is odourless.

Only install the device in compliance with the national
installation regulations.

Please observe the local regulations.

Observe the national gas regulations.

Only install, operate and store the device 

TTK 125 S

 in a

room measuring more than 4 m

2

.

Store the device in a way that no mechanical damage can
occur.

Please note that the connected pipelines must not contain
any sources of ignition.

R290 is a refrigerant that complies with European
environmental regulations. No part of the cooling circuit
may be perforated.

Observe the maximum refrigerant capacity in the technical
data.

Do not drill through or burn.

Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.

Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.

Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.

The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.

Summary of Contents for 1120000124

Page 1: ...TRT BA TTK125S TC220617TTRT03 010 EN TTK 125 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Page 2: ...ing the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions...

Page 3: ...arge the collected condensate before transport and storage Do not drink it Health hazard Only use original spare parts for otherwise safe and functional operation cannot be ensured Safety warnings for...

Page 4: ...t companies for cooling and air conditioning or by Trotec Safety signs and labels on the device Note Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers an...

Page 5: ...nt of an emergency 1 Switch the device off 2 Disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective...

Page 6: ...the device is not being used observe the following storage conditions Only store the device in a room measuring more than 4 m2 Only position the device in rooms where there is no source of ignition e...

Page 7: ...filter inserted into the air inlet Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the...

Page 8: ...8 EN dehumidifier TTK 125 S 1 2 3 4 5...

Page 9: ...y switch Selection of relative room humidity 13 Mains switch Switching the device on and off Is illuminated when the device is switched on 14 Condensation tank LED Illuminated when the condensation ta...

Page 10: ...operation mode the device dehumidifies the air constantly regardless of the humidity To start continuous operation mode set the rotary switch 12 to Max Automatic defrost If the room temperature is bel...

Page 11: ...e condensation tank if need be Clean the device according to the Maintenance chapter Store the device according to the Transport and storage chapter Available accessories Warning Only use accessories...

Page 12: ...ght position Condensate is leaking Check the device for leaks The compressor does not start Check the room temperature Observe the device s permissible operating range according to the technical data...

Page 13: ...nd or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and...

Page 14: ...onditioning or by Trotec Safety signs and labels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean t...

Page 15: ...lifetime If you remove the condensation tank from the device and reinsert it after emptying the compressor will switch back on with a delay of approx 3 min This delay is also enabled in optional hygro...

Page 16: ...Operating range relative humidity 50 90 RH Max permissible pressure 3 0 MPa Pressure suction side 0 6 MPa Pressure outlet side 2 1 MPa Air volume flow 250 m h Mains connection 220 240 V 50 Hz Power co...

Page 17: ...EN 17 dehumidifier TTK 125 S Wiring diagram With operating hours counter...

Page 18: ...18 EN dehumidifier TTK 125 S With operating hours counter and MID counter...

Page 19: ...EN 19 dehumidifier TTK 125 S Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions...

Page 20: ...socket 8 Water tank baseplate 25 Spinning castor with brake 42 Defrost sensor 9 Control s box 26 Spinning castor without brake 43 Compressor 10 Control s protection bars 27 Insulating plate 44 Finned...

Page 21: ...2013 3113 as amended devices that are no longer usable must be collected separately and disposed of in an environmentally friendly manner Declaration of conformity Declaration of conformity in accord...

Page 22: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: