background image

12

Maintenance

1.  Always remove and store the battery separately from the auger 

powerhead. Always remove the battery before attempting any 

maintenance or adjustment.

3.  If blade performance decreases, turn unit off and disconnect 

battery. Carefully inspect cutting edge of blades for any nicks or 

shiny areas. If blades show any of these signs, they should be 

resharpened or replaced.

TIP REPLACEMENT

1. Remove the auger from the powerhead.

2.  Remove the hex bolt and nut that retains the auger tip (just above 

the blade guard).

3.  Using locking pliers, grasp the point and pull out. 

4.  With locking pliers, push in new point and holder aligning bolt 

hole in point with holes in auger shaft. DO NOT damage end of 

point.

NOTE: 

When installing holder in auger shaft, edges of holder may 

shave off.

5. Insert retaining bolt and tighten with nut.

BLADE REPLACEMENT

1. Remove the auger from the powerhead.

2. Remove the two hex bolts that retain each blade on each side.

3.  It is recommended that both blades be sharpened or replaced at 

the same time.

WEAR GLOVES AND USE EXTREME CAUTION WHEN HANDLING 

THE AUGER TIP AND BLADES. The tip and blades will be sharp to 

the touch even when too dull to cut ice.

!

DANGER

Summary of Contents for 107387

Page 1: ... identifies important safety messages in this manual Failure to follow this important safety information may result in serious injury or death MODEL 107387 Operation Manual Part 106632 Rev A 120V Lithium Ion Cordless Ice Auger ...

Page 2: ...1100 W 120th Ave Suite 600 Westminster CO 80234 720 287 5182 For Service or Questions Call 1 877 487 8275 720 287 5182 www trophystrike com Trophy StrikeTM is a brand of ...

Page 3: ...4 General Safety 5 Safety Decals 6 Auger Assembly 7 Overview of Components 8 Operating Precautions 9 Battery Use and Care 9 Charging the Battery 10 Operation 11 Maintenance 12 Tip Replacement 12 Blade Replacement 12 Transporting 13 Storage 14 Troubleshooting 15 Warranty Specifications Back Cover ...

Page 4: ...you have any questions or concerns about the safe operation of this equipment Intended Use Do not use the ice auger for any purpose other than for which it was designed Any other use is unauthorized and may result in serious injury or death Personal Protective Equipment When operating this ice auger it is essential that you wear safety gear including goggles or safety glasses steel toed shoes and ...

Page 5: ... under the influence of alcohol drugs or medication Do not allow a person who is tired or otherwise impaired or not completely alert to operate the ice auger Do not carry the unit between holes with the motor running Always keep hands feet hair and loose clothing away from the auger Keep all screws nuts and bolts tight The battery should be removed before any repairs are attempted If the auger bec...

Page 6: ...ty warning decals are attached and in readable condition Replace missing or defaced decals Contact Trophy Strike at 1 877 487 8275 for replacement decals Trophy Strike is a registered trademark of Frictionless World 1100 W 120th Avenue Westminster Colorado 80234 SN No load speed 325rpm Weight 22 Lbs 120V Lithium Ion Battery powered Auger Powerhead Model 107387 TM 106640 ...

Page 7: ...mbly Attaching the auger Attach the auger to the output shaft on the bottom of the powerhead lining up the holes in the auger with the output shaft and securing with M8 1 25 x 35mm socket cap screw SOCKET CAP SCREW ...

Page 8: ...8 Overview of Components 15 AUGER EXTENSION AUGER BLADES TRIGGER ON OFF SWITCH BATTERY HAND GRIP SAFETY CONTROL BUTTON 8 DIA AUGER FORWARD REVERSE SWITCH AUGER TIP ...

Page 9: ...ly occurs flush with water If liquid contacts eyes additionally seek medical help Liquid ejected from the battery may cause irritation or burns Always remove the battery when the Ice Auger is not in use or before maintenance or to free the blade when stuck The Ice Auger has a sharp blade that can cause injury or damage to property Always use the blade protector when the tool is not in use This too...

Page 10: ...ED flashes green Battery is charging LED steady green The battery is fully charged and can be removed LED flashes red battery fault or overheated If the charger is plugged in and no LED lights are illuminated unplug and check with your nearest authorized service center Do not attempt to use the charger To avoid the risk of damage and injury only use the charger to recharge Trophy Strike 120V batte...

Page 11: ...e sure that you have a firm footing and hold the hand grips firmly 7 Allow the blade to cut at its own speed into the ice Do not push down on the auger If the auger starts to cut the ice more slowly it may be time to sharpen the blades We recommend that the blades be sharpened annually or when cutting performance deteriorates 8 If the auger becomes stuck release the trigger switch Move the forward...

Page 12: ...p just above the blade guard 3 Using locking pliers grasp the point and pull out 4 With locking pliers push in new point and holder aligning bolt hole in point with holes in auger shaft DO NOT damage end of point NOTE When installing holder in auger shaft edges of holder may shave off 5 Insert retaining bolt and tighten with nut BLADE REPLACEMENT 1 Remove the auger from the powerhead 2 Remove the ...

Page 13: ... auger or powerhead remove the auger from the powerhead and transport separately Remove the battery by pressing and holding the latch button and sliding it out of the charger 3 Never carry or transport the auger from the blade end 4 Avoid transporting the powerhead near metal shavings or chips that could come into contact with the battery connections on the powerhead 5 Avoid transporting in advers...

Page 14: ...to bottom of auger STORAGE OF THE CHARGER AND BATTERY For long term storage it is preferable that the battery is fully charged and stored in a dry place at a temperature between 50 77 F 10 25 C The charger should be stored in the same conditions as the battery taking care that no foreign objects such as metal chips enter through the ventilation slots of the charger or short out the connectors on t...

Page 15: ...FF Switch simultaneously to power the ice auger Check that the battery is charged Check that the battery is fully engaged into the battery receptacle on the powerhead Auger blades jump on ice Sharpen or replace auger blades Auger blades turn slowly on ice Sharpen or replace point Replace blades Auger is jammed into the hole being cut Release the trigger switch Move the forward reverse lever into r...

Page 16: ...he location of the nearest service center Record the information below for future reference 1100 W 120th Ave Suite 600 Westminster CO 80234 720 287 5182 Trophy StrikeTM is a brand of For Service or Questions Call 1 877 487 8275 720 287 5182 www trophystrike com SKU Part No 107387 Description 120V Lithium Ion Cordless Ice Auger Rated Voltage 120 Volts DC Auger Speed 325 rpm no load Auger Diameter 8...

Reviews: