6.2 Maintenance
6.2.1 Introduction
To keep your
Sentro Vortex Wireless
in
the best possible condition and minimise
downtime, Trolex strongly recommends that
you carry out regular planned preventative
maintenance and keep records of the
maintenance carried out.
The planned preventative maintenance
for
Sentro Vortex Wireless
consists of
a number of tasks carried out at regular
intervals on a cumulative basis, ie. at
12 months do the 1 month task, the 3
month task, the 6 month task AND the 12
month task. These tasks are listed in the
maintenance schedule below:
Equipment Name
Task Type
Task
Number
Interval
Sentro Vortex Wireless
Check
6.2.2
1 month
Sentro Vortex Wireless Batteries
Replace
6.2.3
200 operating
hours
Sentro Vortex Wireless Sensing
Probe
Clean
6.2.4
3 months
Sentro Vortex Wireless Sensing
Probe
Function Test
6.2.5
12 months