Technical specification
Operating temperature
-10°C to +45°C
Humidity
0 – 95% RH (non-condensing)
Housing material
PC/ABS – stainless steel
Ingress protection
Main enclosure: IP65
Particle flow path, cap open: IP42
Weight
8.2kg
Cable entries
3x M20 with removable blanks
1x M20 breather gland
1x M20 USB connector
Nominal power supply
100V to 240V AC 50/60Hz
9 to 18V DC
Power consumption
15W
Communications
RS485 data output with MODBUS RTU protocol
Ethernet (MODBUS TCP/IP)
External power output
15V 1A for powering external devices
(e.g. 4G modem)
3V3 1A
Connectivity
Trolex Breathe PC application
Data download
External USB interface
Instrument data storage
6GB
User interface
128x64 dot matrix display with RGB backlight
Navigation keypad (Membrane)
Visual alarms
Custom alarm set points
Latching/non-latching
Indicators
1x Green High Brightness LED – Sensor heartbeat
1x Blue High Brightness LED – Communications
Self-test routine
Sensor hardware, Circuitry and Communications on ‘power on’
Manual self-test during use
Certification
CE compliant