![Trojan TRILLIUM Series User Manual Download Page 17](http://html1.mh-extra.com/html/trojan/trillium-series/trillium-series_user-manual_1170813017.webp)
17
U S E R ’ S
G U I D E
17
TR 25.6-25
Low Voltage
Any cell voltage < 2.0V for 0.3 seconds
All cell voltages > 2.3V
High Voltage
Any cell voltage > 3.9V for 2 seconds
All cell voltages < 3.8V
High Discharge Current
Discharge current >70A instantaneously
Load removed
High Charge Current
Charge current > 70A instantaneously
Charger removed
High Temperature
Temperature > 140°F (+60°C)
Temperature < 140°F (+60°C)
Low Temperature
Temperature < -4°F (-20°C)
Temperature > -4°F (-20°C)
Short Circuit
Short circuit detected
Load removed
*
If the attached charger requires a voltage to be present to begin charging, a restart will not take place when the charger is attached.
* *
See Section 4.11, “Battery Start-Up,” for details on using the Status button
.
If Group 24 or Group 27 batteries do not automatically restart, then follow the “Battery Start-up” section. If you
have any difficulty getting a Trillium battery to provide power, contact your dealer or Trojan Technical Support for
assistance.
11. BATTERY RECYCLING
Trillium batteries are recyclable, and should not be disposed of as household or landfill waste. If you need assistance
in recycling your Trillium battery, contact your dealer or Trojan Battery Company’s technical support engineers as
outlined at the front of this manual.
12. BATTERY ABBREVIATIONS
A
Ampere
M6/M8
6mm/8mm terminal
Ah
Ampere-hour
SOC
State of Charge
AWG
American Wire Gauge
T
Temperature
°C
Degrees Celsius
V
Volt
DOD
Depth of Discharge
VDC
Volts DC
°F
Degrees Fahrenheit
Summary of Contents for TRILLIUM Series
Page 1: ...USER S GUIDE...
Page 18: ...T R O J A N B A T T E R Y 18 NOTES...
Page 19: ...19 U S E R S G U I D E 19...