Trojan TRILLIUM Series User Manual Download Page 15

15

U S E R ’ S  

G U I D E   

15

6.8.  OTHER CHARGING INFORMATION

 

î

Chargers which utilize an automatic desulfation or equalization mode are not recommended.

 

î

 When the battery is being charged, the display indicator on Group 24 and Group 27 batteries will usually be on, 
displaying a pattern and color indicting the state of charge 

(See “Indicator Light” for a List of Display States)

.

 

î

 To protect against potential damage, if the battery is shut off due to excessive charge current or high voltage, it 
will not turn on when a charger is detected (See “Automatic Safety Shutdowns”).

 

î

 If a battery shuts off due to low state-of-charge, it should be recharged as soon as possible. Failure to do so may 
render the battery permanently unusable.

 

î

 Depending upon the initial state-of-charge and the size of the load, even small parasitic loads such as motor 
controllers and on-board chargers can fully discharge batteries in as little as a few days. For instance, a 25mA 
load amounts to 0.6Ah discharge per day. Be sure to understand the parasitic loads in your application and set an 
appropriate charging interval.

7.  STORAGE AND SHIPPING

The following tips will help ensure that your batteries emerge from storage in good condition:

î

 

 

Store in a cool and dry location, protected from the elements.

î

 

  

Disconnect from equipment to eliminate potential parasitic loads that may discharge the battery.

î

 

 

Prior to long-term storage of the battery, Trojan Battery recommends that the battery be fully charged. Storing a 
discharged battery can result in permanent damage or decreased run time.

î

 

  On Group 24 and Group 27 batteries, in order to turn the battery off for shipping or extended storage (3 months 
or more), press and hold the status button. The status light will initially show the current state of the battery, and 
after five seconds it will change to a solid red. At that point, release the button to turn the battery off. If the button 
is not released after being held for fifteen seconds, the light will turn off and the battery shutdown process will 
not be completed.

Note: If the Battery is Attached to a Charger When It is Shut Down, It May Turn Back On.

î

 

 When batteries are taken out of storage they should be given an initial charge as outlined in Section 6 prior to use.

8.   MAXIMIZING THE PERFORMANCE OF YOUR TRILLIUM BATTERY

î

 

  Follow all the procedures in this User’s Guide for proper installation, maintenance, and storage.

î

 

 If you have any questions or concerns about battery care, please contact Trojan Battery Company’s technical 
support engineers at 800-423-6569 Ext. 3045 or +1-562-236-3045 before a problem develops.

IF YOU SHIP THIS BATTERY, THERE ARE SEVERAL STATE, FEDERAL AND INTERNATIONAL LAWS, RULES, REGULATIONS 

AND REQUIREMENTS REGARDING LITHIUM BATTERIES THAT YOU MUST COMPLY WITH. YOU MUST UTILIZE A QUALIFIED 

SHIPPING AGENT PROPERLY CERTIFIED FOR HAZARDOUS MATERIALS (“HAZMAT”) SHIPMENTS.

Summary of Contents for TRILLIUM Series

Page 1: ...USER S GUIDE...

Page 2: ...ufacturer of the world s most trusted deep cycle batteries The battery you purchased was engineered by Trojan to deliver superior power performance durability and reliability for use in a broad range...

Page 3: ...e optimum performance and long life from your new investment If you have any questions concerning safety precautions or for any assistance in installing or using the battery in your system contact Tro...

Page 4: ...BATTERY INSTALLATION 7 5 PREVENTIVE MAINTENANCE 12 6 CHARGING 12 7 STORAGE AND SHIPPING 15 8 MAXIMIZING THE PERFORMANCE OF YOUR TRILLIUM BATTERY 15 9 WHAT TO EXPECT FROM YOUR TRILLIUM BATTERY 16 10 A...

Page 5: ...ife in a variety of applications The line currently consists of three different models Group 24 size 12 8V 92Ah with state of charge gauge Group 27 size 12 8V 110Ah with state of charge gauge U1 size...

Page 6: ...e pressure washers to clean the battery or immerse the battery in water Never short circuit the battery terminals Never physically damage the battery this includes without limitation puncturing droppi...

Page 7: ...x 8mm threaded hole Lithium ion batteries including Trillium batteries weigh substantially less than lead acid batteries of comparable capacity Many types of equipment are designed to utilize the weig...

Page 8: ...on top of the lug Do not place a washer between the battery terminal and the lug as this will create high resistance and cause excessive heating of the connection If assistance is needed in determinin...

Page 9: ...TION PARALLEL CONNECTION SERIES PARALLEL CONNECTION To increase voltage connect batteries in series This will not increase the system capacity To increase capacity connect batteries in parallel This w...

Page 10: ...stricting airflow by tightly packing batteries together The batteries should have a minimum of 0 50 12 7 mm of space between them to allow for adequate airflow 4 11 BATTERY START UP The start up instr...

Page 11: ...m literature If required technical support is available as outlined at the front of this manual 4 14 PROHIBITION AGAINST UNBALANCED LOADS All loads in Trillium systems composed of multiple batteries i...

Page 12: ...iously been utilized Most deep cycle battery chargers will charge the batteries but many will shut off prior to the battery reaching 100 SOC In order to facilitate ease of use and ensure safe operatio...

Page 13: ...if there is a desire to use the batteries immediately after unplugging the charger the contactor can be manually closed using the status button on each battery Note Once a set of batteries have achiev...

Page 14: ...ry voltage be sure that Group 24 or Group 27 batteries are turned on If the charger provides charge without detecting battery voltage and the battery is shut off the battery will turn on automatically...

Page 15: ...s that may discharge the battery Prior to long term storage of the battery Trojan Battery recommends that the battery be fully charged Storing a discharged battery can result in permanent damage or de...

Page 16: ...ing Status button High Voltage Any cell voltage than 3 90V for 1 second All cell voltages 3 75V for 5 seconds Status button High Discharge Current Discharge current 250A for 30 seconds or 400A instant...

Page 17: ...attached See Section 4 11 Battery Start Up for details on using the Status button If Group 24 or Group 27 batteries do not automatically restart then follow the Battery Start up section If you have a...

Page 18: ...T R O J A N B A T T E R Y 18 NOTES...