Zanté electric shower
OPERATING fUNCTIONS
Power on indicator
(fig.24)
When the electricity supply to the shower is
switched on at the isolating switch, the ‘power’
indicator will light.
Low pressure indicator
(fig.24)
A red indication means the water pressure has
fallen below the minimum required for correct
operation of the shower. In this state the low
pressure cut-out has operated. This switches
off power to the heating elements preventing
undue temperature rises (water will continue to
flow). Power will automatically be restored when
adequate water pressure returns.
If the indication fluctuates between red and
green, this means the pressure is only just
sufficient and operating difficulties may be
encountered.
A green indication shows that water pressure is
sufficient for satisfactory operation of the shower.
Overheat cut-out
During normal operation if an overheat
temperature is sensed, power to the elements
will be reduced. Water will continue to flow.
When the temperature has cooled sufficiently,
power to the elements will be automatically
restored to the previous setting at the time of
interruption.
Safety cut-out
The unit is fitted with a thermal cut-out safety
device. In the event of abnormal operation
which could cause unsafe temperatures within
the unit, the device will disconnect the heating
elements. It will require a visit from a qualified
engineer to determine the nature of the fault
and replace the safety device, once the unit has
been repaired.
Power on
indicator
Low pressure
indicator
Fig.