background image

Installation and user guide- 20 

8  FAQ Frequently asked questions 

During the installation 

QI2. When a 18+ lbs (8kg) body falls in the pool during the tests, my siren triggers after 20 s or doesn’t 
trigger, why? 
 

RI2.1.  Your  pool  has  dimensions  bigger  than  20  x  40  feet  or  a  really  special  shape.  One 
detector isn’t sufficient. Ask advice at your local reseller. 
RI2.2.  Your  falling  detector  isn’t  installed  in  the  recommended  location.  The  fall  is  realized 
beyond the 28 feet detection radius. Please move it to the recommended location. See §5.2 
RI2.3. If none of these conditions seem to be the source of the problem, please ask advice at 
your local reseller or contact our after sale service: 

 [email protected] 

 

During the utilization 
 
QU1. The siren triggers in an inopportune way. 

RU1.1. The meteorological conditions are too unfavorable (strong wind, thunderstorms…) and 
disturb the functions of the device. 
RU1.2.  Your  cleaning  robot  isn’t  compatible  with  your  falling  detector.  It  creates  an  event 
assimilated or identical to a child fall. Please ask advices to your local reseller. 
RU1.3. If none of those conditions seems to be the dysfunction origin, please ask advices to 
your local reseller or contact or after sale service: 

[email protected] 

 

 
 

GENERAL SECURITY TIPS

 

 
This  alarm  system  can  not  substitute  for  parents’  watchfulness  and/or  responsible  grown-up,  which 
remains the essential factor for 5- years’ old children safety. It substitutes neither to horse sense nor to 
individual responsibility.

 

 
 
 
 

 
 

 
 

WARNING 

 

Improper installation, testing, maintenance or operation of this product can make the alarm fail 
to  sound,  increasing  the  risk  of drowning.    
Follow  all  instructions in  this  document  to reduce  this 
risk. 
 

IMPORTANT SAFETY INFORMATION ABOUT YOUR POOL ALARM 

Even when correctly installed, maintained, tested, and operated, this alarm cannot completely 
prevent drowning:
 

 

In some situations, the alarm will not sound when a child enters the pool. 

o

  If  a  child  enters  the  pool  slowly  or  gradually,  without  disturbing  the  water  much, 

the alarm may not detect it. 

o

  The alarm may not detect very small child (under 18 lbs) entering the pool. 

o

  When  weather  (e.g.,  wind)  or  other  factors  disturb  the  water,  the  alarm 

automatically reduces sensitivity or becomes  INACTIVE DETECTION, to prevent 
excessive  false  alarms.    When  this  happens,  a  child  may  enter  the  pool  without 
the alarm sounding. 

o

  When the alarm is INACTIVE DETECTION to allow swimming, it will not sound if a 

child enters the pool or if a child is drowning. 

o

  After swimming with the alarm in INACTIVE DETECTION mode, the alarm will not 

sound if a child enters the water until the device switches in DETECTION mode
Depending  on  the  time  the  water  lasts  to  calm  down,  the  reactivation  may  take 
more than 10 minutes (depending on weather conditions). 

Summary of Contents for TRIT001-US

Page 1: ...OFF mode 17 7 8 Replacing the batteries 18 7 9 I have an issue with my falling detector 18 8 FAQ Frequently asked questions 20 9 Warranty and after sale services 23 10 Monthly Tests 24 FCC REGULATION...

Page 2: ...subsurface pool device which detects the fall of an 18 lbs child by providing automatically sounding an alarm This device is not intended to replace any other safety consideration that is adult superv...

Page 3: ...n unit with a black hose 1 rigid tube with attachment screws 1 remote alarm system 4 1 5V LR20 alkaline batteries supplied 1 AC DC Adapter 110V 12V for the remote system 1 fixing kit screws washers ta...

Page 4: ...M mode during 20mn max The LED starts to blink in green Immobilize the TRITON TM alongside the edge of the pool with the supplied fixation kit Your device is now operational cf 5 4 UTILISATION All the...

Page 5: ...totally still Then it goes back to DETECTION mode Be patient because this can take more than 10 minutes to happen NEVER LEAVE THE POOL UNATTENDED IN THIS MODE o In case of high winds the device can t...

Page 6: ...ODE To reduce your reaction time TRITON includes a remote alarm system with a radio receiver which can be set up near your living room or other convenient location This will also sound a siren in case...

Page 7: ...N THIS MODE INACTIVE DETECTION LED blinks in red quickly To switch to this mode From the INACTIVE DETECTION mode type the password initially 1234 The siren CAN emits a 85 dB signal at 10 feet when tri...

Page 8: ...8 Default Signage Default Signage LOW BATTERIES LED blinks in red quickly One low tone sound once in a minute BURP HARDER DEFAULTS the device requires maintenance LED LED LED all the LEDs are blinkin...

Page 9: ...ng ones are incompatible with falling detector systems The proper performance of TRITON is not correctly achieved if used in parallel with tarpaulins WARNING TRITON is kitted up with a powerful siren...

Page 10: ...he siren is audible from the inside of your house Your falling detector should be placed in the middle of the largest length on a brink recommended position for rectangular shaped pool If your pool do...

Page 11: ...ode facultative In this mode the siren is attenuated and stops by itself after 5 seconds See chapter 7 5 page X for more details For these tests TRITON should be in DETECTION mode the LED blinks in gr...

Page 12: ...d with care to guarantee the waterproofness and the good operating state of your device Check that the 2 main black joints are correctly positioned in their location on the base Put back in place the...

Page 13: ...te siren you should synchronize the two devices a Choose a location for your remote device o 70 feet away max from the TRITON o Near an electrical plug b Plug the power supply to the remote siren IMAG...

Page 14: ...mmended to place the siren as high as possible on your wall pay attention to the power supply wire IMAGE 5 o Insert the 2 tapping inserts in the 2 new holes o Screw down the 2 screws through the siren...

Page 15: ...avoid the formation of algae in the probe In case of restart of your falling detector after an extended stop please proceed the tests explained in 5 4 In case of issue please contact immediately your...

Page 16: ...oved In that case your device understands your request by responding with a high tone sound PIP but can t restart immediately the monitoring The LED blinks in red It will progressively start the monit...

Page 17: ...s slowly in yellow and a high tone sound is heard PIP Enter the password change code 1111 the mode will be validated by the LED blinking once in green and a high tone sound PIP Enter your new password...

Page 18: ...off the TRITON see 7 6 upper Remove with care the 4 caps with the help of a flat screwdriver Unscrew the 4 screws and remove the cover Remove the used batteries Place the new batteries in their locati...

Page 19: ...e us to give you a quick answer please give us a short description of the problem Please send our technicians your address and a quick drawing of your swimming pool with its dimensions length width de...

Page 20: ...t substitute for parents watchfulness and or responsible grown up which remains the essential factor for 5 years old children safety It substitutes neither to horse sense nor to individual responsibil...

Page 21: ...from the pool or alert adults to their presence For more information contact the Association of Pool and Spa Professionals www TheAPSP org This alarm does not replace responsible adult supervision Wh...

Page 22: ...risk of a cold shock response How to rescue a child from the pool 1 Extend a long object such as a pole shepherd s hook or towel and pull in the child or throw the child a floating object 2 If the ch...

Page 23: ...r failures resulting from an accident shock negligence or misuse a failure or defect in the electrical supply in an external electrical circuit lightning the use of parts not supplied by ABTYS and una...

Page 24: ...passed failed 7 Test achieved the 8 Test achieved the Passed failed passed failed 9 Test achieved the 10 Test achieved the Passed failed passed failed 11 Test achieved the 12 Test achieved the Passed...

Reviews: