Installation and user guide- 17
WARNING: TRITON™ performances are not guaranteed beyond the wind level specified in the ASTM
standard F2208-02
e1
.
7.5 Attenuated siren mode
In this (facultative) mode, your siren is sounding shortly and with a low power to enable you doing
your installation and monthly tests without annoying the neighborhood.
-
The test mode lasts for 5mn.
-
Entering and going out of test mode will be validated by a high tone sound (PIP) and a low tone
sound (BURP), respectively.
To enter the test mode, please enter the manual mode code (122344: the LED
:
blinks
slowly in yellow and a high tone sound is heard (PIP)) then enter the test code (1133) : the test mode
will be validated by the LED
:
blinking once in green and a high tone sound (PIP).
While the device goes out of the test mode, the siren makes a low tone sound (burp).
7.6 Password Change mode
In this mode, you can change the password that enables you to switch from “DETECTION” mode
to “INACTIVE DETECTION” mode.
To change the password:
-Enter the manual mode code (122344): the LED
:
blinks slowly in yellow and a high tone
sound is heard (PIP).
-Enter the password change code (1111): the mode will be validated by the LED
:
blinking
once in green and a high tone sound (PIP).
-Enter your new password. The new password will be validated by the LED
:
blinking once in
green and a high tone sound (PIP).
In case of bad entry or any entry which contents wrong key combinations (any password starting
with a double key (
11xx, 22xx, 33xx, 44xx) or 1223 and 3444, already used for the OFF and MANUAL code
) The bad
entry will be cancelled and indicated by the LED
:
blinking once in yellow and a low tone sound
(BURP).
After a good or wrong password entry, the device goes out of the “password change” mode.
7.7 OFF mode
While the TRITON™ is OFF, all the LEDs are turned OFF.
While TRITON is OFF, a human or another safety system should keep watch of
the pool, if in use by children!
To stop the device, enter the 3444 code followed by your password (1234 initially). TRITON™
validates by the LED
:
blinking once in green and a high tone sound (PIP) will be heard.
IMAGE 2 idem P4
To reactivate TRTION™ :
o
Press any key twice (for instance 11 or 22 …)
o
TRITON™ will validate by the LED
:
blinking once in green, a high tone sound
(PIP), will be heard and the LED
: