6
Original Instructions
Wear hearing protection
Wear eye protection
Wear breathing protection
Wear head protection
Wear hand protection
Read instruction manual
Caution!
WARNING
: Moving parts can cause crush and cut injuries
Toxic fumes or gases!
Indoors use only
Class II construction (double insulated for additional protection)
Internal time-lag fuse with rated current 3.15A
Conforms to relevant legislation and safety standards
Environmental Protection
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or retailer
for recycling advice
Description of Symbols
The rating plate on your tool may show symbols. These represent important information about
the product or instructions on its use.
The declared vibration total value has been measured in accordance with a standard test
method and may be used for comparing one tool with another. The declared vibration total
value may also be used in a preliminary assessment of exposure.
WARNING
: The vibration emission during actual use of the power tool can differ from the
declared total value depending on the ways in which the tool is used. There is the need to
identify safety measures to protect the operator that are based on an estimation of exposure
in the actual conditions of use (taking account of all parts of the operating cycle such as the
times when the tool is switched off and when it is running idle in addition to the trigger time).
WARNING
: Always wear ear protection where the sound level exceeds 85dB(A) and limit the
time of exposure if necessary. If sound levels are uncomfortable, even with ear protection, stop
using the tool immediately and check the ear protection is correctly fitted and provides the
correct level of sound attenuation for the level of sound produced by your tool.
Thank you for purchasing this Triton tool. This manual contains information necessary
for safe and effective operation of this product. This product has unique features and,
even if you are familiar with similar products, it is necessary to read this manual
carefully to ensure you fully understand the instructions. Ensure all users of the tool
read and fully understand this manual.
Introduction
T3.15A
V
Volts
~, AC
Alternating current
A, mA
Ampere
n
0
No load speed
n
Rated speed
opm
Orbits or oscillations per minute
°
Degrees
Hz
Hertz
DC
Direct current
W, kW
Watt, kilowatt
/min or min
-1
Operations per minute
rpm
Revolutions per minute
dB(A)
Decibel sound level (A weighted)
m/s
2
Metres per second squared
(vibration magnitude)
Ø
Diameter
Technical Abbreviations Key
Specification
Model number
TMUTL
Input voltage
120V~ 60Hz
Power
2.5A
No load speed
11,000–21,000min
-1
Oscillating arc range
3.2°
Protection class
Ingress protection
IP20
Dimensions (L x W x H)
2-7/16 x 3-15/16 x 11"
Weight
3.7lb
Sound and vibration information
Sound pressure L
PA
80dB(A)
Sound power L
WA
91dB(A)
Uncertainty K
3dB(A)
Weighted vibration a
h
3.68m/s
2
Uncertainty K
1.5m/s
2
The sound intensity level for the operator may exceed 85dB(A) and sound protection
measures are necessary.
As part of our ongoing development, specifications of TRITON products may alter
without notice.
725112_Manual.indd 6
11/12/2018 12:39
Summary of Contents for TMUTL
Page 2: ...2 7 8 9 10 2 3 4 5 6 11 12 11 9 14 3 2 13 725112_Manual indd 2 11 12 2018 12 39...
Page 3: ...3 Fig I Fig II Fig III Fig IV 725112_Manual indd 3 11 12 2018 12 39...
Page 4: ...4 Fig V Fig VI Fig VII 1 2 3 Fig VIII Fig IX 725112_Manual indd 4 11 12 2018 12 39...
Page 5: ...5 Fig XI Fig XII Fig X 725112_Manual indd 5 11 12 2018 12 39...