background image

12

WARNING!

The shower must not be  

positioned where it will be  

subjected to freezing conditions.

INSTALLATION - SITING OF THE SHOWER

IMPORTANT: 

The unit must be mounted on 

a flat surface which covers the full width and 
length of the backplate. It is important that 
the wall surface is flat otherwise difficulty 
may be encountered when fitting the cover 
and subsequent operation of the unit may  
be impaired.

IMPORTANT: 

If installing onto a tiled wall, 

ALWAYS

 mount the unit on the surface of  

the tiles. 

NEVER

 tile up to the unit.

SITING OF THE SHOWER

•  Refer to

 fig.8 

for the correct siting of 

the shower. Position the unit where it will 

NOT

 be in direct contact with water from 

the showerhead. Position the shower unit 
vertically.

•  Allow enough room between the ceiling and 

the shower to access the cover top screws.

IMPORTANT: Water regulations (fig.8)

•  It is required that the showerhead be 

constrained by a fixed or sliding attachment 

so that it can only discharge water at a point 
not less than 25mm above the spill-over level 
of the relevant bath, shower tray or other 
fixed appliance’. 

•  If the riser kit is supplied with a ‘soapdish 

hose retainer’ or bespoke ‘hose retainer’, it 
will in most cases meet this requirement. If 
the showerhead can still be placed within a 
bath, basin or shower tray within the 25mm 
limit, then a double check valve, or similar, 

MUST be fitted in the supply pipework 
to prevent back-flow

.

Pressure relief safety device

•  A pressure relief device (PRD) is designed 

into the shower unit which complies with 
European standards. The PRD provides a level 
of appliance protection should an excessive 
build up of pressure occur within the shower.

DO NOT 

operate the shower with a damaged or 

kinked shower hose, or a blocked showerhead. 
This may cause the PRD to operate.

•  When commissioning, the showerhead 

must be removed from the flexible hose. 
Failure to follow this procedure may cause 
the PRD to operate.

•  Make sure the shower is positioned over a 

bath or shower tray. If the PRD operates, 
then water will eject from the bottom of 
the unit. Should this happen, turn off the 
electricity and water supplies to the shower 
at the isolating switch and stopvalve. 
Contact Customer Experience for advice on 
replacing the PRD.

Shower unit

must not

be within

an area

1 metre

from base

Height of 

showerhead

and shower 

to suit user's

requirement

Spillover

level

25 mm minimum

Shower unit can

be mounted either

side of riser rail

Outline of bath

or shower tray

*Fig.8

*

(diagrammatic view – not to scale)

Summary of Contents for T70 GSI

Page 1: ...when not in use This is a safety procedure recommended for all electrical appliances The showerhead and hose supplied with this product are a safety critical part of your shower Failure to use genuin...

Page 2: ...ing other than those specified This appliance is intended to be permanently connected to the water mains and not connected by a hose set A suitable double pole isolation switch for supply disconnectio...

Page 3: ...ulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS EN 806 2 2 The supply pipe must be flushed to clear debris before co...

Page 4: ...re setting At different times of the year you may have to adjust the position of the temperature control to maintain your desired temperature setting c The stabiliser valve minimises variations in sho...

Page 5: ...r to the wall 13 15 Plumbing connections 16 Electrical connections 17 Fitting The Cover valve knob positions 18 19 Commissioning procedure 20 Cleaning the filter installers service engineers only 21 F...

Page 6: ...08mm 108mm 308mm ENTRY POINTS DIMENSIONS WATER Left Bottom Back Top Side Right Bottom Back Side CABLE Left Bottom Back Top Side Right Bottom Back Side Back Back Others Others Inlet connection 15mm dia...

Page 7: ...the whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket out...

Page 8: ...ng in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlets in those ro...

Page 9: ...es per minute the inlet of the shower for full performance for 8 5Kw 9 5Kw Minimum running pressure and flow to 150kPa 1 5 bar at 11 litres per minute the inlet of the shower for full performance for...

Page 10: ...he incoming water Economy setting single red circle Economy uses only one of the elements within the heater can NOTE If the stated flow rate required for the unit cannot be met due to low water pressu...

Page 11: ...ure exceeds the showering safety limit the power to the elements will be removed completely although water will continue to flow When the temperature has cooled sufficiently power to the elements will...

Page 12: ...espoke hose retainer it will in most cases meet this requirement If the showerhead can still be placed within a bath basin or shower tray within the 25mm limit then a double check valve or similar MUS...

Page 13: ...the fitting 180 fig 9B Secure with the screw included in the screw pack fig 9C NOTE The Inlet is not fixed during production Deviations from the designated entry points will invalidate product approv...

Page 14: ...ut positions Decide if top or bottom pipe entry is required Once chosen carefully remove the appropriate cut out using a junior hacksaw and file PLEASE NOTE NONE of the cut outs are designed as snap o...

Page 15: ...nto position leaving the base of the screw head protruding 6mm out from the wall Hook the backplate over the top screw and fit the bottom fixing screw into position Do not fully tighten the screws at...

Page 16: ...ss point to the isolator IMPORTANT Before completing the connection of the water supply to the inlet of the shower flush out the pipework to remove all swarf and system debris This can be achieved by...

Page 17: ...IMPORTANT Fully tighten the terminal block screws and make sure that no cable insulation is trapped under the screws Loose connections can result in cable overheating NOTE The supply cable earth cond...

Page 18: ...bottom fig 15 2 With the cover off the shower turn the stabiliser valve spindle fully clockwise until resistance is felt fig 16 4 With the cover off the shower turn the temperature control to the 5 O...

Page 19: ...the OFF position and the temperature control is turned fully clockwise the 5 o clock position Offer the cover to the unit Carefully guide the cover onto the backplate making sure the wires are not tr...

Page 20: ...s to flow from the flexible hose Slowly turn the temperature control fully anti clockwise fig 20 It will take about thirty seconds for a smooth flow of water to be obtained while air and any debris is...

Page 21: ...on SWITCH OFF the electricity and water supply at the mains The inlet filter is situated inside the water inlet fitting fig 21 To gain access to the filter remove the cover and bottom trimplate Unscre...

Page 22: ...ase in ambient water temperature 2 3 1 Readjust flow rate to give increased flow 2 3 2 Select economy power 3 Water temperature cycling hot cool at intervals 3 1 Heater cycling on thermal cut out 3 1...

Page 23: ...ed while commissioning 6 3 1 Fit new PRD Commission unit with showerhead removed 6 4 Water pressure above specified maximum for unit see rating label 6 3 1 Fit pressure reducing valve to inlet and the...

Page 24: ...electric products are labelled accordingly with the crossed out wheeled bin symbol This indicates for disposal purposes at end of life that these products must be taken to recognised collection point...

Page 25: ...TS USED 0 1 2 H O T HOT COLD Turn the main power isolator switch ON Power Knob setting Temperature Knob setting To START the shower turn the power knob from the OFF position to Cold Economy or High 1...

Page 26: ...26...

Page 27: ...27...

Page 28: ...ners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verif...

Reviews: