T300si electric shower

Power on indicator 

(fig.)

When the electricity supply to the shower is 
switched on at the isolating switch, the start/
stop button surround will light.

Low pressure indicator 

(fig.)

If this indicator flashes, it means the water 
pressure has fallen below the minimum required 
for correct operation of the shower, resulting in 
the low pressure cut-out operating. This switches 
off power to the heating elements preventing 
any maintained temperature rises (water will 
continue to flow) while at the same time the 
‘cold’ indicator will light.
When enough water pressure returns, the ‘low 
pressure’ and ‘cold’ indicators both extinguish 
and the power will automatically be restored to 
the power setting at the time of interruption.

Selector mode indicators 

(fig.)

Next to each control button there is an LED 
which lights up when the button is pressed, 
visually showing which shower mode is in 
operation.

Phased shutdown

In use, when the Start/Stop button is pressed, 
power is switched off to the elements. Water 
continues to flow for a few seconds, flushing 
out any remaining hot water. This makes sure 
the next immediate user will not receive a slug 
of hot water if standing under the showerhead 
when starting the shower. 

note:

 The shower should always be switched off 

in this manner prior to isolating at the double 
pole isolating switch.

overheat cut-out

During normal operation if an overheat 
temperature is sensed, power to the elements 
will be reduced. Water will continue to flow. 
When the temperature has cooled sufficiently, 
power to the elements will be automatically 
restored to the previous setting at the time of 
interruption.

note:

 In normal use, it is in order to leave the 

water supply permanently on to the shower 
unit,  but  as  with  most  electrical  appliances, 

the  unit  must  be  switched  off  at  the 
isolating switch when not in use.

Power on

indicator

High power

indicator

Economy power

indicator

Cold only

indicator

Low pressure

indicator

Fig.

Operating functions

OPERATING FUNCTIONS

Summary of Contents for T300si

Page 1: ...Installation and operating instructions T300si electric shower 2180280J May 2008 Installers please note these instructions are to be left with the user...

Page 2: ...t 17 Fitting the control panel 18 Fitting the remote pack cover 18 Commissioning 19 Operating the shower 21 Operating functions 23 Cleaning 24 Instructions for installers and service engineers only 25...

Page 3: ...nd could also cause the Pressure Relief Device in the unit to operate This product is not suitable for mounting into steam rooms or steam cubicles PLUMBING The plumbing installation must comply with W...

Page 4: ...cannot obtain cooler water first check the showerhead has not become blocked This book contains all the necessary fitting and operating instructions for your Triton T300si electric shower please read...

Page 5: ...9 Solenoid valve 10 Guide pockets 11 Can and element assembly 12 Thermal safety cut out main 13 Earth connection 14 Control cable clamp 15 Thermal cut out outlet 16 Outlet pipe 17 Transformer 18 Conn...

Page 6: ...ircuits This may be part of the consumer unit or a separate unit 6 A 45 amp double pole isolating switch with a minimum contact gap of 3 mm in both E 002 A 230 240V ac supply If you are installing a s...

Page 7: ...and cable size there is a maximum permissible circuit length 9 The shower circuit should be separated from other circuits by at least twice the diameter of the cable or conduit 9 1 The current rating...

Page 8: ...m ow rate of eleven litres per minute For all units the maximum static pressure must be no greater than 1000kPa 10 bar If in any doubt the pressure should be checked Note If the stated ow rate is not...

Page 9: ...ouble check valve or a similar device must be fitted in the supply pipework to prevent back flow Pressure relief safety device A pressure relief device PRD is designed into the shower unit which compl...

Page 10: ...mark the position of the 15 mm hole Drill and channel a route as required Place and position the control cable between the remote pack and control panel Make sure there is enough slack cable at the re...

Page 11: ...mote pack is installed in a loft area the following requirements must be met for future servicing purposes a There must be no risk of the remote pack heated water pipe or PRD tube becoming frozen b Th...

Page 12: ...wall Entry positions for the mains water are from the bottom or from the rear Cable entry is via the top or rear Note Deviations from the designated entry points will invalidate product approvals If...

Page 13: ...of the remote pack flush out the pipework to remove all swarf and system debris This do this connect a hose to the pipework and turn on the mains water supply long enough to clear the debris to waste...

Page 14: ...from the remote pack Any surplus can be cut off as required Note The water outlet does not need to be vertically above or below the control panel If required the outlet adaptor and control panel can...

Page 15: ...as they are similar in diameter and length the PRD tube is clear Important Do not bend either the PRD tube or heated water pipe sharply as they will kink and restrict the water flow If a tight bend i...

Page 16: ...bulkhead and its cover are supplied assembled Separate the two halves by carefully prising apart at the smaller of the two elbow apertures Secure the elbow to the bulkhead body with the three screws s...

Page 17: ...to the back of the bulkhead Apply PTFE tape to the threaded connector Screw the bulkhead assembly onto the threaded connector until tight to the wall and the two fixing holes are aligned Secure to th...

Page 18: ...l block screws and check that no cable insulation is trapped under the screws Loose connections can result in cable overheating Note The supply cable earth conductor must be sleeved The outer sheath o...

Page 19: ...access panel fig 28 to reveal the connector socket Cable entry into the remote pack is through one of the built in cut outs Remove the protective dust covers from both ends of the control cable Once t...

Page 20: ...e purge pin is located on its two pins the factory set position see fig 34 Locate the tags on the cover into the holes on the backplate and guide into position Secure the cover in position with the th...

Page 21: ...old and low pressure This flashing sequence lasts about twenty seconds All lights will then go out except the Start Stop surround indicating that power is on to the unit Press the Start Stop button fi...

Page 22: ...off its two pins and in order to store it for use at a later date replace it on one of the pins Replacing the remote pack cover Locate the tags on the cover into the holes on the backplate and guide i...

Page 23: ...switch All lights will go out except the Start Stop surround indicating that power is on to the unit The shower is now ready for normal operation To start the shower Press the Start Stop button and im...

Page 24: ...a different temperature to the same number position on high To decrease the shower temperature Turn the temperature control anti clockwise fig 36 This will increase the flow of water through the showe...

Page 25: ...in operation Phased shutdown In use when the Start Stop button is pressed power is switched off to the elements Water continues to flow for a few seconds flushing out any remaining hot water This make...

Page 26: ...once the unit has been repaired W 007 A WARNING DO NOT use abrasive or aggressive cleaning products when cleaning the shower as they may damage the unit Cleaning CLEANING Before cleaning turn off the...

Page 27: ...id inlet fig 42 To gain access to the filter remove the cover then disconnect and remove the compression fitting Also depending on the incoming pipework arrangements if there is not enough slack in th...

Page 28: ...Solenoid valve 83304130 10 Outlet pipe assembly 85000090 11 Trimplate 7051754 12 PRD O ring 83301330 13 Remote pack cover 85200030 14 PCB control panel 7072569 15 Control panel assembly white 8740002...

Page 29: ...er supply mains or tank fed If tank fed replumb to mains water supply or see 4 2 4 If mains fed make sure that the mains stopvalve is fully open and there are no other restrictions in the supply while...

Page 30: ...nit with showerhead removed Fit pressure reducing valve to inlet and then fit new PRD 4 2 3 4 2 4 4 3 1 4 3 2 4 4 1 5 1 1 6 1 1 6 2 1 6 2 2 7 1 1 7 2 1 7 3 1 7 4 1 required see rating label Reduction...

Page 31: ...T300si electric shower 29...

Page 32: ...onshowers co uk Triton Showers Triton Road Nuneaton Warwickshire CV11 4NR Triton is a division of Norcros Group Holdings Limited TRiTon STandaRd GuaRanTee Triton guarantee this product against all mec...

Reviews: