Triton T22i Installation And Operating Instructions Manual Download Page 4

Shower pump

INTrODUCTION

This book contains all the necessary fitting and 
operating instructions for your Triton power 
shower pump. Please read them carefully.
Care taken during the installation will provide a 
long and trouble free life from your unit.

ImporTanT:

 All plumbing connections must 

be completed before making the electrical 
connections.

Please read through the whole of this book 
before beginning your installation.

SPECIfICaTION

Standards and approvals

Splashproof rating IPX4
Complies with the requirements of current British 
and European safety standards for household 
and similar electrical appliances.
Complies with requirements of the British 
Electrotechnical Approvals Board (BEAB).
Meets with Compliance with European 
Community Directives (CE).

SafETy WarNINGS

a.

  Under no circumstances must this pump 

be connected to a mains cold water 
supply. Failure to comply will invalidate the 
guarantee.

b.

  The shower pump MUST NOT be used if 

suspected of being frozen.

c.

  The pump MUST be earthed.

d.

  Switch off immediately at isolating switch if 

water ceases to flow during use.

e.

  DO NOT operate the unit outside the 

guidelines laid out in 

'site requirements'

.

f.

  This pump is to be used for providing water 

to a shower only.

In  the  interest  of  electrical  safety  a  30mA 
residual  current  device  (RCD)  should  be 
installed  in  all  uK  electric  and  pumped 
shower  circuits.  this  may  be  part  of  the 
consumer unit or a separate unit.

DuTY CYCLE

30 minutes on @ 12.5 litres/min — 
120 minutes off.

15 minutes on @ 4 litres/min — 
120 minutes off.

rEquIrED prEssurEs

maximum pump working head (Hmax) is 

30 metres.

minimum static head is 1 metre.

! ImporTanT !

tHE PumP 

musT

 NOt BE CONNECtED 

tO tHE mAINs COLD WAtER suPPLY.

It Is DEsIGNED FOR 

GraVITY sYsTEms onLY.

Summary of Contents for T22i

Page 1: ...Installers please note these instructions are to be left with the user 2180504C February 2009 Installation and operating instructions T22i Shower pump 6479496 ...

Page 2: ...ts 5 Siting of the pump 6 Installation 7 Commissioning 8 Spare parts 9 Fault finding 10 Guarantee Service Policy Etc Rear cover To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service before installation Telephone Facsimile E mail 0844 980 0730 0844 980 0744 technical tritonshowers co uk ...

Page 3: ...1 Pipe runs must be as short as possible and standard full flow isolating gate valves or lever valves MUST be fitted to both inlet and outlet sides of the pump as an independent means of isolating the water should maintenance or servicing be necessary 1 12 DO NOT use jointing compound on any pipe fittings use only the flexible hoses supplied to connect to the pump 1 13 It is strongly recommended t...

Page 4: ...ETY WARNINGS a Under no circumstances must this pump be connected to a mains cold water supply Failure to comply will invalidate the guarantee b The shower pump MUST NOT be used if suspected of being frozen c The pump must be earthed d Switch off immediately at isolating switch if water ceases to flow during use e Do not operate the unit outside the guidelines laid out in site requirements f This ...

Page 5: ...Shower pump KEY TO MAIN COMPONENTS fig 1 1 Pump 2 Connector hose X4 3 Inlet filter washer X2 4 Rubber washer X2 Fig 1 1 2 3 4 ...

Page 6: ... both fused at 5A Gate valve Service valves Other draw offs Stopvalve Cold water cistern Pump 1 metre head Essex flange 1 2 Fig 2 Diagrammatic view not to scale warning This pump is designed to supply water to a shower only and the cold water cistern 225 litres It is advisable to check that the replenishment rate from the float operated valve meets the output requirements Both the hot and cold wat...

Page 7: ...a person using a fixed bath or shower cannot access the pump without using tools To comply with BS6700 the hot water storage temperature should not exceed 60ºC Operation at this temperature will also reduce the rate of formation of limescale in the system The water supply must not exceed 65ºC 149ºF THE PUMP MUST NOT BE CONNECTED TO THE MAINS COLD WATER SUPPLY DO NOT connect into the rising vent pi...

Page 8: ... electricity supply is SWITCHED OFF before making the electrical connections DO NOT OPERATE THE PUMP DRY This may cause damage to the seals and will invalidate the guarantee Note The pump motor has automatically resetting thermal overload protection WARNING Installation of the pump will break the earth continuity of the pipework installation It is important that the earth be restored by cross bond...

Page 9: ...ot and cold feed pipes from the mixer valve to the outlet flexible push in connectors f At this stage do not connect the hot and cold water supplies from the cistern and cylinder to the inlet flexible push in connectors Wait until the commissioning procedure has been completed Note Do not overtighten the connections on the pump ports and take care to prevent any system debris from entering the pum...

Page 10: ... the cylinder and system to fill 3 Open both isolating valves and flush through thoroughly 4 Allow water to flow to waste for two or three minutes to make sure any installation debris and air is completely flushed from the system 5 Check the system pipework for leaks 6 Close both isolating valves Remove the waste hoses and connect the cistern supply pipework and cylinder pipework to the pump inlet...

Page 11: ...Shower pump Spare PARTS Ref Description Part No 1 Pump assembly T22IOOM 2 Hose assembly X1 83309460 3 Filter seal pack X2 of each 83309470 2 3 1 3 ...

Page 12: ...eck other appliances and if necessary contact local Electricity Company 1 3 1 Check all connections and secure where necessary 1 4 1 Check isolating valve is fully open 1 4 2 Check head of water 1 4 3 Make sure the inlet filter is clean 1 5 1 Replace the pump unit Contact Triton Customer Service 2 1 1 See causes 1 1 1 2 1 3 1 4 1 5 and 1 6 2 2 1 Check for evidence of freezing Contact Triton Custom...

Page 13: ...Shower pump 11 ...

Page 14: ...Shower pump 12 ...

Page 15: ...ling Requirements To ensure that local and national legislation is complied with Triton plc ask that you dispose of any obsolete product in an environmentally friendly manner Do not place obsolete products in a wheelie bin ...

Page 16: ...el number and power rating of the product together with the date of purchase 2 Based on information given over the telephone a Triton Customer Service Advisor will attempt to diagnose the fault and confirm whether a site visit from a qualified service engineer is required 3 All products attended to by a Triton service engineer must be installed in full accordance with the Triton installation guide...

Reviews: