INTrODUCTION
This book contains all the necessary fitting and
operating instructions for your Triton power
shower pump. Please read them carefully.
Care taken during the installation will provide a
long and trouble free life from your unit.
ImporTanT:
All plumbing connections must
be completed before making the electrical
connections.
Please read through the whole of this book
before beginning your installation.
SPECIfICaTION
Standards and approvals
Splashproof rating IPX4
Complies with the requirements of current British
and European safety standards for household
and similar electrical appliances.
Complies with requirements of the British
Electrotechnical Approvals Board (BEAB).
Meets with Compliance with European
Community Directives (CE).
SafETy WarNINGS
a.
Under no circumstances must this pump
be connected to a mains cold water
supply. Failure to comply will invalidate the
guarantee.
b.
The shower pump MUST NOT be used if
suspected of being frozen.
c.
The pump MUST be earthed.
d.
Switch off immediately at isolating switch if
water ceases to flow during use.
e.
DO NOT operate the unit outside the
guidelines laid out in
'site requirements'
.
f.
This pump is to be used for providing water
to a shower only.
In the interest of electrical safety a 30mA
residual current device (RCD) should be
installed in all uK electric and pumped
shower circuits. this may be part of the
consumer unit or a separate unit.
DuTY CYCLE
30 minutes on @ 12.5 litres/min —
120 minutes off.
15 minutes on @ 4 litres/min —
120 minutes off.
rEquIrED prEssurEs
maximum pump working head (Hmax) is
30 metres.
minimum static head is 1 metre.
! ImporTanT !
tHE PumP
musT
NOt BE CONNECtED
tO tHE mAINs COLD WAtER suPPLY.
It Is DEsIGNED FOR
GraVITY sYsTEms onLY.