Shower pump

0

faUlT fINDING

Problem/Symptom  Cause 

action/Cure

1.1

  Pump motor thermal 

overload protection 
activated.

1.2

  Mains electricity 

supply fault. 
 
 

1.3

 

Loose wiring 

connections.

1.4

  Insufficient flow to 

operate flow switch. 

1.5 

Failed pump motor. 

2.1

  Pump motor not 

running.

2.2

  Pump or shower unit 

frozen.

2.3

  Water turned off.

2.4

  No water in cold 

storage cistern.

2.5

  System blockage. 

2.6

  Blocked showerhead 

on shower unit.

2.7

  Blocked filter.

3.1

  Faulty flow switches.

1.1.1

 Allow the pump motor to cool and 

automatically reset. 

1.1.2

 Check the pump is adequately ventilated.

1.2.1

 Blown fuse. Check supply, and renew or 

reset fuse. If it fails again, contact Customer 
Service. 

1.2.2

 

Power cut? Check other appliances and if 

necessary contact local Electricity Company.

1.3.1

 

Check all connections and secure where 

necessary.

1.4.1

 Check isolating valve is fully open. 

1.4.2

 Check head of water. 

1.4.3

 Make sure the inlet filter is clean.

1.5.1

 

Replace the pump unit. Contact Triton 

Customer Service.

2.1.1

 See causes 1.1, 1.2, 1.3, 1.4, 1.5, and 1.6. 

2.2.1 

Check for evidence of freezing. Contact 

Triton Customer Service for advice.

2.3.1 

Check isolation valves and water supply.

2.4.1

 See 2.3.1. 

2.5.1 

Isolate supplies and inspect inlet filter, 

pump outlet and showerhead.

2.6.1 

Clean the showerhead. Refer to separate 

instructions.

2.7.1 

Clean filter.

3.1.1

 

Isolate electric supply to pump. Contact 

Triton Customer Service for advice.

1

  Pump motor 

does not operate. 

 
 
 
 

 

 
 

 

2

  Poor or no 

water flow.

 

 

 

 

3

  Pump does not

 

switch off.

any maintenance or repair to the pump musT be carried out by a suitably 

competent person.

Summary of Contents for T22i

Page 1: ...Installers please note these instructions are to be left with the user 2180504C February 2009 Installation and operating instructions T22i Shower pump 6479496 ...

Page 2: ...ts 5 Siting of the pump 6 Installation 7 Commissioning 8 Spare parts 9 Fault finding 10 Guarantee Service Policy Etc Rear cover To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service before installation Telephone Facsimile E mail 0844 980 0730 0844 980 0744 technical tritonshowers co uk ...

Page 3: ...1 Pipe runs must be as short as possible and standard full flow isolating gate valves or lever valves MUST be fitted to both inlet and outlet sides of the pump as an independent means of isolating the water should maintenance or servicing be necessary 1 12 DO NOT use jointing compound on any pipe fittings use only the flexible hoses supplied to connect to the pump 1 13 It is strongly recommended t...

Page 4: ...ETY WARNINGS a Under no circumstances must this pump be connected to a mains cold water supply Failure to comply will invalidate the guarantee b The shower pump MUST NOT be used if suspected of being frozen c The pump must be earthed d Switch off immediately at isolating switch if water ceases to flow during use e Do not operate the unit outside the guidelines laid out in site requirements f This ...

Page 5: ...Shower pump KEY TO MAIN COMPONENTS fig 1 1 Pump 2 Connector hose X4 3 Inlet filter washer X2 4 Rubber washer X2 Fig 1 1 2 3 4 ...

Page 6: ... both fused at 5A Gate valve Service valves Other draw offs Stopvalve Cold water cistern Pump 1 metre head Essex flange 1 2 Fig 2 Diagrammatic view not to scale warning This pump is designed to supply water to a shower only and the cold water cistern 225 litres It is advisable to check that the replenishment rate from the float operated valve meets the output requirements Both the hot and cold wat...

Page 7: ...a person using a fixed bath or shower cannot access the pump without using tools To comply with BS6700 the hot water storage temperature should not exceed 60ºC Operation at this temperature will also reduce the rate of formation of limescale in the system The water supply must not exceed 65ºC 149ºF THE PUMP MUST NOT BE CONNECTED TO THE MAINS COLD WATER SUPPLY DO NOT connect into the rising vent pi...

Page 8: ... electricity supply is SWITCHED OFF before making the electrical connections DO NOT OPERATE THE PUMP DRY This may cause damage to the seals and will invalidate the guarantee Note The pump motor has automatically resetting thermal overload protection WARNING Installation of the pump will break the earth continuity of the pipework installation It is important that the earth be restored by cross bond...

Page 9: ...ot and cold feed pipes from the mixer valve to the outlet flexible push in connectors f At this stage do not connect the hot and cold water supplies from the cistern and cylinder to the inlet flexible push in connectors Wait until the commissioning procedure has been completed Note Do not overtighten the connections on the pump ports and take care to prevent any system debris from entering the pum...

Page 10: ... the cylinder and system to fill 3 Open both isolating valves and flush through thoroughly 4 Allow water to flow to waste for two or three minutes to make sure any installation debris and air is completely flushed from the system 5 Check the system pipework for leaks 6 Close both isolating valves Remove the waste hoses and connect the cistern supply pipework and cylinder pipework to the pump inlet...

Page 11: ...Shower pump Spare PARTS Ref Description Part No 1 Pump assembly T22IOOM 2 Hose assembly X1 83309460 3 Filter seal pack X2 of each 83309470 2 3 1 3 ...

Page 12: ...eck other appliances and if necessary contact local Electricity Company 1 3 1 Check all connections and secure where necessary 1 4 1 Check isolating valve is fully open 1 4 2 Check head of water 1 4 3 Make sure the inlet filter is clean 1 5 1 Replace the pump unit Contact Triton Customer Service 2 1 1 See causes 1 1 1 2 1 3 1 4 1 5 and 1 6 2 2 1 Check for evidence of freezing Contact Triton Custom...

Page 13: ...Shower pump 11 ...

Page 14: ...Shower pump 12 ...

Page 15: ...ling Requirements To ensure that local and national legislation is complied with Triton plc ask that you dispose of any obsolete product in an environmentally friendly manner Do not place obsolete products in a wheelie bin ...

Page 16: ...el number and power rating of the product together with the date of purchase 2 Based on information given over the telephone a Triton Customer Service Advisor will attempt to diagnose the fault and confirm whether a site visit from a qualified service engineer is required 3 All products attended to by a Triton service engineer must be installed in full accordance with the Triton installation guide...

Reviews: