Triton T22i Installation And Operating Instructions Manual Download Page 16

Triton Showers

Triton Road

Nuneaton

Warwickshire  CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

TriTon STandard GuaranTee

Triton guarantee this product against all 

mechanical and electrical defects arising from 

faulty workmanship or materials for a period of 

two years for domestic use only, from the date of 

purchase, provided that it has been installed by 

a competent person in full accordance with the

fitting instructions.
Any part found to be defective during this 

guarantee period we undertake to repair or replace 

at our option without charge so long as it has been 

properly maintained and operated in accordance 

with the operating instructions, and has not been 

subject to misuse or damage.
This product must not be taken apart, modified or 

repaired except by a person authorised by Triton. 

This guarantee applies only to products installed 

within the United Kingdom and does not apply to 

products used commercially. This guarantee does 

not affect your statutory rights.

What is not covered:

1

Breakdown due to: 

a)

 use other than domestic 

use by you or your resident family; 

b)

 wilful act or neglect; 

c)

 any malfunction 

resulting from the incorrect use or quality of 

electricity, gas or water or incorrect setting of 

controls;

d)

 faulty installation.

2

Repair costs for damage caused by foreign 

objects or substances.

3

Total loss of the product due to non-availability 

of parts.

4

Compensation for loss of use of the product or 

consequential loss of any kind.

5

Call out charges where no fault has been found 

with the appliance.

6

The cost of repair or replacement of pressure relief 

devices, showerheads, hoses, riser rails and/or wall 

brackets, isolating switches, electrical cable, fuses 

and/or circuit breakers or any other accessories 

installed at the same time.

7

The cost of routine maintenance, adjustments, 

overhaul modifications or loss or damage arising 

therefrom, including the cost of repairing 

damage, breakdown, malfunction caused by 

corrosion, furring, pipe scaling, limescale, system 

debris or frost.

TRITON reserve the right to change product specification without prior notice. E&OA. © TRITON SHOWERS 2009

Customer Service: 

0844 980 0750

Trade installer Hotline: 

0844 980 0730

Fax:

 

0844 980 0744

www.tritonshowers.co.uk 

e-mail: [email protected]

Extended Warranty AVAILABLE NOW. Call 0844 980 0740 for more details.

Service Policy

In the event of a product fault or complaint occurring, the 

following procedure should be followed:

1

Telephone Customer Service on 0844 980 0750 having available, 

your details including post code, the model number and power 

rating of the product, together with the date of purchase.

2

Based on information given over the telephone, a Triton Customer 

Service Advisor will attempt to diagnose the fault and confirm 

whether a site visit from a qualified service engineer is required.

3

All products attended to by a Triton service engineer must be 

installed in full accordance with the Triton installation guide 

applicable to the product. (Every product pack contains an 

installation guide, however, they can also be bought via our 

Customer Service Spares Department).

4

Our engineer will require local parking and if a permit is required 

this must be available to the engineer on arrival at the call. 

5

It is essential that you or an appointed representative (who must 

be over 18 years of age) is present for the duration of the service 

engineer's visit. If the product is in guarantee you must produce 

proof of purchase.

6

Where a call under the terms of guarantee has been booked 

and the failure is not product related (i.e. scaling and furring, 

incorrect water pressure, pressure relief device operation or 

electrical/plumbing installation fault) a charge will be made. A 

charge will also be issued if nobody is at home when the service 

engineer calls or adequate parking/permit is not available.

7

If the product is no longer covered by the guarantee an up front 

fixed fee will be charged before the site visit.

8

Should proof of purchase not be available on an “in-guarantee” 

call, or should the service engineer find that the product is no 

longer under guarantee, the engineer will charge the same 

fixed price and the customer will be expected to pay the 

engineer before he leaves. If payment is not made on the day an 

administration charge will be added to the fixed charge.

9

If a debt is outstanding from a previous visit, or from any other 

Triton purchase, Triton reserves the right to withhold service until 

the debt has been settled.

10

Triton takes the health, safety and wellbeing of its employees very 

seriously and expects customers to treat all staff members with 

respect. Should any employee feel threatened or receive abuse, 

either verbally or physically, Triton reserves the right to withhold 

service and will support the employee with a legal prosecution.

replacement Parts Policy

Availability: It is the policy of the manufacturer to maintain parts 

availability for the duration of production and a period of five years 

thereafter, in accordance with industry standards.

Spare parts are available via our website, 

www.tritonshowers.co.uk

,

or by telephoning Triton Customer Service Spares Department.  

Payment should be made by credit/debit card (excluding American 

Express or Diners Card).

Payment can also be made by pre-payment of a pro forma invoice by cheque or money order.

Summary of Contents for T22i

Page 1: ...Installers please note these instructions are to be left with the user 2180504C February 2009 Installation and operating instructions T22i Shower pump 6479496 ...

Page 2: ...ts 5 Siting of the pump 6 Installation 7 Commissioning 8 Spare parts 9 Fault finding 10 Guarantee Service Policy Etc Rear cover To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service before installation Telephone Facsimile E mail 0844 980 0730 0844 980 0744 technical tritonshowers co uk ...

Page 3: ...1 Pipe runs must be as short as possible and standard full flow isolating gate valves or lever valves MUST be fitted to both inlet and outlet sides of the pump as an independent means of isolating the water should maintenance or servicing be necessary 1 12 DO NOT use jointing compound on any pipe fittings use only the flexible hoses supplied to connect to the pump 1 13 It is strongly recommended t...

Page 4: ...ETY WARNINGS a Under no circumstances must this pump be connected to a mains cold water supply Failure to comply will invalidate the guarantee b The shower pump MUST NOT be used if suspected of being frozen c The pump must be earthed d Switch off immediately at isolating switch if water ceases to flow during use e Do not operate the unit outside the guidelines laid out in site requirements f This ...

Page 5: ...Shower pump KEY TO MAIN COMPONENTS fig 1 1 Pump 2 Connector hose X4 3 Inlet filter washer X2 4 Rubber washer X2 Fig 1 1 2 3 4 ...

Page 6: ... both fused at 5A Gate valve Service valves Other draw offs Stopvalve Cold water cistern Pump 1 metre head Essex flange 1 2 Fig 2 Diagrammatic view not to scale warning This pump is designed to supply water to a shower only and the cold water cistern 225 litres It is advisable to check that the replenishment rate from the float operated valve meets the output requirements Both the hot and cold wat...

Page 7: ...a person using a fixed bath or shower cannot access the pump without using tools To comply with BS6700 the hot water storage temperature should not exceed 60ºC Operation at this temperature will also reduce the rate of formation of limescale in the system The water supply must not exceed 65ºC 149ºF THE PUMP MUST NOT BE CONNECTED TO THE MAINS COLD WATER SUPPLY DO NOT connect into the rising vent pi...

Page 8: ... electricity supply is SWITCHED OFF before making the electrical connections DO NOT OPERATE THE PUMP DRY This may cause damage to the seals and will invalidate the guarantee Note The pump motor has automatically resetting thermal overload protection WARNING Installation of the pump will break the earth continuity of the pipework installation It is important that the earth be restored by cross bond...

Page 9: ...ot and cold feed pipes from the mixer valve to the outlet flexible push in connectors f At this stage do not connect the hot and cold water supplies from the cistern and cylinder to the inlet flexible push in connectors Wait until the commissioning procedure has been completed Note Do not overtighten the connections on the pump ports and take care to prevent any system debris from entering the pum...

Page 10: ... the cylinder and system to fill 3 Open both isolating valves and flush through thoroughly 4 Allow water to flow to waste for two or three minutes to make sure any installation debris and air is completely flushed from the system 5 Check the system pipework for leaks 6 Close both isolating valves Remove the waste hoses and connect the cistern supply pipework and cylinder pipework to the pump inlet...

Page 11: ...Shower pump Spare PARTS Ref Description Part No 1 Pump assembly T22IOOM 2 Hose assembly X1 83309460 3 Filter seal pack X2 of each 83309470 2 3 1 3 ...

Page 12: ...eck other appliances and if necessary contact local Electricity Company 1 3 1 Check all connections and secure where necessary 1 4 1 Check isolating valve is fully open 1 4 2 Check head of water 1 4 3 Make sure the inlet filter is clean 1 5 1 Replace the pump unit Contact Triton Customer Service 2 1 1 See causes 1 1 1 2 1 3 1 4 1 5 and 1 6 2 2 1 Check for evidence of freezing Contact Triton Custom...

Page 13: ...Shower pump 11 ...

Page 14: ...Shower pump 12 ...

Page 15: ...ling Requirements To ensure that local and national legislation is complied with Triton plc ask that you dispose of any obsolete product in an environmentally friendly manner Do not place obsolete products in a wheelie bin ...

Page 16: ...el number and power rating of the product together with the date of purchase 2 Based on information given over the telephone a Triton Customer Service Advisor will attempt to diagnose the fault and confirm whether a site visit from a qualified service engineer is required 3 All products attended to by a Triton service engineer must be installed in full accordance with the Triton installation guide...

Reviews: