19
Operating functions
OPERATING FUNCTIONS
Clean showerhead
After a preset number of START/STOP button
operations (nominally 75), the start up routine
acts as normal but instead of a blue ‘OK’ the
display backlight turns red and a flashing ‘CS’
alternating with a flashing ‘showerhead symbol’
and ‘CLEAN’ appear
(fig.33)
.
This is a reminder to clean the showerhead. It
does NOT indicate a defect to the shower.
To remove the red ‘CS’ from the display, press
the POWER and COLD buttons together for
three seconds. Alternatively you can continue
as normal by pressing the START/STOP button
but the ‘symbol’ and ‘CLEAN’ will continue to
flash at the side of the °C figure for a further five
shower operations. After this it will stop (whether
you clean the showerhead or not). The shower
will then reset automatically for a further preset
number of shower operations before flashing the
reminder again.
Low pressure
When the display backlight turns red and
‘LP’ and ’LOW PRESSURE
’
flash alternately, it
means the water pressure has fallen below the
minimum required for correct operation of the
shower
(fig.34)
. This causes the low pressure
switch to operate turning off power to the
heating elements preventing any maintained
temperature rises. Water will stop flowing until
the unit has been reset.
Press the ‘START/STOP’ button once to reset the
shower. The shower will shut down and then
begin its start up routine.
If the low water pressure continues, the ‘LOW
PRESSURE’ display will flash once more and the
shower will require resetting again.
If the pressure is acceptable the display will
change to show ‘OK’ in a blue backlight and the
shower will run as normal.