background image

In the event of a product fault or complaint occurring, 
the following procedure should be followed:
DO NOT REMOVE THE PRODUCT

1.  Telephone Customer Experience on 

024 7637 2222

 having 

available your details including post code, the model number 
and power rating of the product, together with the date of 
purchase and, where applicable, details of the particular fault.

2.  If required, the Customer Experience Advisor will arrange for a 

qualifi ed engineer to call.

3.  All products attended to by a Triton service engineer must be 

installed in full accordance with the Triton installation guide 
applicable to the product. (Every product pack contains an 
installation guide, however, they can also be downloaded free at 
www.tritonshowers.co.uk). 

4.  Our engineer will require local parking and if a permit is required, 

this must be available to the engineer on arrival at the call.

5.  If loft access is required for isolation or to complete a repair, 

the loft must have a fi xed access ladder and be boarded, with 
appropriate lighting from the access point to and around the 
repair area.

6.  It is essential that you or an appointed representative (who must 

be over 18 years of age) is present for the duration of the service 
engineer’s visit. If the product is in guarantee you must produce 
proof of purchase.

7.  Where a call under the terms of guarantee has been booked 

and the failure is not product related (i.e. scaling and furring, 
incorrect water pressure, pressure relief device operation or 
electrical/plumbing installation fault) a charge will be made. A 
charge will also be issued if nobody is at the property when the 
service engineer calls or adequate parking/permit is not available.

8.  If the product is no longer covered by the guarantee an 
 

up-front fi xed fee will be charged before the site visit.

9.  Your receipt must be retained as proof of purchase. Should proof 

of purchase not be available on an ‘in-guarantee’ call, or should 
the service engineer fi nd that the product is no longer under 
guarantee, the engineer will charge the same fi xed price and 
will request payment prior to departing. If payment is not made 
on the day an administration charge will be added to the fi xed 
charge.

10.  If a debt is outstanding from a previous visit, or from any other 

Triton purchase, Triton reserves the right to withhold service until 
the debt has been settled.

11.  Triton takes the health, safety and wellbeing of its employees 

very seriously and expects customers to treat all staff members 
with respect. Should any employee feel threatened or receive 
abuse, either verbally or physically, Triton reserves the right to 
withhold service.

Replacement Parts Policy

In line with AMDEA guidelines, Triton retains functional spares 
for as long as there is a market for them and in most cases, well 
beyond.  Due to the vast array of product types, the life cycle of 
products can vary and therefore so can the length of time parts 
can be supplied. Spare parts can be ordered via our online spare
parts store or by telephoning our Triton Customer Experience
team on 

024 7637 2222

. Payment should be made by credit/

debit card (excluding American Express or Diners Card). Payment
can also be made by pre-payment of a pro-forma invoice, by
cheque or postal order.

Telephone orders are based on information given during 
the call.  Before contacting Triton, please verify your 
requirements using the Information contained in the
user guide. Triton cannot accept liability for incorrect part 
identifi cation. 

TRITON STANDARD GUARANTEE

With the exception of accessories, Triton guarantee the
product against all manufacturing defects for a period of 

year

 (for domestic or light commerical use only) from the 

date of purchase, provided that it has been installed by a 
competent person in full accordance with the fi tting
instructions. 
All accessories such as shower heads, hoses and riser rails carry 

1 year

 parts only guarantee against manufacturing defects.

Any part found to be defective during this guarantee period 
we undertake to repair or replace at our option without 
charge, so long as it has been properly maintained and
operated in accordance with the operating instructions and 
has not been subject to misuse or damage. This product must 
not be taken apart, modifi ed or repaired except by a person 
authorised by Triton. This guarantee applies only to products 
installed within the United Kingdom and does not apply to 
products used commercially.  This guarantee does not affect 
your statutory rights.

What is not covered:

1.  Breakdown due to:  

a)

 wilful act or neglect; 

b) 

any malfunction resulting from the incorrect use or 

quality of electricity, gas or water or incorrect setting of 

controls; 

c) 

failure to install in accordance with this installation 

guide.

2.  Claims for missing parts once the product has been 

installed.

3.  Repair costs for damage caused by foreign objects or 

substances.

4.  Total loss of the product due to non-availability of parts.
5.  Compensation for loss of use of the product or 

consequential loss of any kind.

6.  Call out charges due to an abortive visit or where no fault 

has been found with the appliance.

7.  The cost of repair or replacement of isolating switches, 

electrical cable, fuses and/or circuit breakers or any other 

accessories installed at the same time. Replacement of the 

Pressure Relief Device that only activates when the shower 

outlet is blocked is also excluded. 

8.  The cost of routine maintenance, adjustments, overhaul 

modifi cations or loss or damage arising therefrom, 

including the cost of repairing damage, breakdown, 

malfunction caused by corrosion, furring, frost or exposure 

to freezing conditions.

9.  Call out charges where the water supply cannot be 

isolated, this includes consequential losses arising from

 

unserviceable supply valves, or inaccessible product or 

valves located in a loft space without suitable access.

For the latest Terms & Conditions please see:

www.tritonshowers.co.uk/terms

Triton Showers
Triton Road
Nuneaton
Warwickshire, CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

Customer Experience: 024 7637 2222

Trade Installer Hotline: 024 7637 8344

www.tritonshowers.co.uk

E-mail: [email protected]

E-mail: [email protected]

UK SERVICE POLICY

Triton reserve the right to change product specifi cation without prior notice. E&OE. © TRITON SHOWERS 2020

Summary of Contents for INSTAFLOW T30IR

Page 1: ...CE The swivel arm supplied with this product is a safety critical part of your shower Failure to use genuine Triton parts may cause injury and invalidate your guarantee FOR YOUR SERVICE REFERENCE NOTE DOWN THE PRODUCT CODE BELOW FROM THE FRONT OR TOP OF THE BOX ALTERNATIVELY REGISTER BY TEL 024 7637 8321 T30IR INSTAFLOW Handwash REGISTER ONLINE ENTER A PRIZE DRAW WIN 100 LOVE2SHOP VOUCHERS VISIT O...

Page 2: ...nd never fit any additional device to restrict the water outlet flow The outlet must not be connected to any tap or fitting other than those specified This appliance is intended to be permanently connected to the water mains and not connected by a hose set Mains water pressure only Minimum inlet pressure 100kPa 1 bar Maximum inlet pressure 1000kPa 10 bar This book contains all the necessary fittin...

Page 3: ...handwash unit as heat can transfer along the pipework and damage components 2 4 DO NOT fit any form of outlet flow control as the outlet acts as a vent for the heater can 2 5 DO NOT use excessive force when making connections to the swivel arm or sprayhead finger tight is sufficient 2 6 All plumbing connections must be completed before making the electrical connections 2 7 This appliance MUST NOT ...

Page 4: ...n top of the unit Liquid could seep through the joint between the cover and back plate and possibly damage the sealing rubber If water becomes too hot and you cannot obtain cooler water first check that the sprayhead is not blocked Secondly leave the product for 5 minutes and run the cycle again INTRODUCTION This book contains all the necessary fitting and operation instructions for your T30IR Ins...

Page 5: ...nit 8 Fitting the unit to the wall 9 Plumbing connections 10 Electrical connections 11 Fitting the swivel arm and cover 12 Commissioning 13 Operating the handwash 14 Operating functions 15 Cleaning 16 Flow rates and temperatures 16 Fault finding 17 18 Spare parts 19 Guarantee service policy etc rear cover PRODUCT FICHE Model 3 0kW Load Profile XXS Energy Efficiency Class A Energy Efficiency 38 Ann...

Page 6: ...rcoswitch 5 Stabiliser valve 6 Pressure Relief Device PRD 7 Can assembly 3kW 8 Thermal Cut Out TCO 9 Outlet pipe 10 PCB 11 Commissioning block 12 Cover Package Contents Handwash unit Cover screw pack 200mm swivel arm Instruction booklet including guarantee 7 8 4 1 2 5 9 6 3 Fig 1 Entry Points Key Water Entry Point Cable Entry Points 10 12 11 ...

Page 7: ...ig 2 within the unit 2 Before making any sort of electrical connection within the installation make sure that no terminal is live If in any doubt switch off the whole installation at the consumer unit 3 The 3kW rated handwash can be connected to a ring main via a 13A fused spur 3 1 The electrical supply must be adequate for the loading of the unit and existing circuits 4 A 30mA residual current de...

Page 8: ...ting compounds on any pipe fittings for the installation Isolating stopvalve Mains water supply Handwash Diagrammatic view not to scale Fig 3 Pressure Relief Safety Device A pressure relief device PRD is designed into the handwash unit which complies with European Standards The PRD provides a level of appliance protection should an excessive build up of pressure occur within the unit DO NOT operat...

Page 9: ...or the mains water is at the bottom Entry for electrical supplies are at the top bottom or back of the unit If top or bottom entry position is chosen the cable entry not being used should have the pipe trim inserted fig 4 Procedure Position the unit on the wall and using the backplate as a template mark the two fixing holes fig 5 Drill and plug the wall An appropriate drill bit should be used If t...

Page 10: ...any debris within the inlet pipe work Procedure Turn off the water supply either at the mains stop valve or the isolating stop valve Make sure the filter is inserted in the pipe before connection This helps to prevent ingress of debris fig 6 Connect the mains water supply to the inlet of the unit via 15mm pipe using the nut and olive supplied fig 7 Check the backplate is square on the wall and the...

Page 11: ... can only be from rear Route the cable into the unit and connect to the terminal block fig 9 as follows Earth cable to terminal marked Neutral cable to terminal marked N Live cable to terminal marked L IMPORTANT When connecting the cable fully tighten the terminal block screws and make sure that no cable insulation is trapped under the screws loose connections can result in cable overheating Make ...

Page 12: ...ature control so that it points at the position fig 12 Replace the cover squarely to the backplate and guide into position so that the control locates correctly into the splined spindle Should any difficulty arise recheck the points above Secure the cover in position with the two retaining screws at the top and bottom of the unit Fig 12 Fig 11 Fig 13 IMPORTANT PLEASE ENSURE COVER SCREWS ARE FULLY ...

Page 13: ...ontrol fully anti clockwise to the maximum flow position fig 12 When a smooth flow of water is obtained rotate the control from minimum to maximum and back again several times to release any trapped air If you are unable to do this during the 30 second timescale please run a second commissioning cycle by again passing your hand in front of the IR lens and once water flows repeat the process above ...

Page 14: ... slowly clockwise fig 18 NOTE There will always be a short time delay between selecting a flow rate and reaching the stable temperature for that flow rate To stop the handwash unit The unit will time out after 30 seconds Alternatively place hand in front of the sensor to turn the unit off Fig 18 5 15cm Activation Range Fig 17 WARMER COOLER WARNING DO NOT TOUCH THE LED PROTECTIVE SHEILDS REMOVING O...

Page 15: ...TARTS HERE dip switch for IR fitting book dip switch for IR fitting book DRAWING CHECKED BY CONTACT design_files tritonshowers co uk WRAS CHECKED BY PART STATUS Triton is a division of Norcros Group Holdings Limited Triton Showers Triton Road Nuneaton Warwickshire UK CV11 4NR TEL 024 7634 4441 FAX 024 7632 4424 www tritonshowers co uk cm IMPORTANT COMPONENT MUST COMPLY WITH ROHS DIRECTIVE 2011 65 ...

Page 16: ...ched to the handwash unit DO NOT use powerful abrasive or solvent cleaning fluids when cleaning the sprayhead assembly as they may damage the plastic fittings The sprayhead is a critical part of the unit In order to maintain maximum performance the sprayhead assembly should be cleaned at regular intervals to prevent build up of deposits from the water supply Blocked spray holes can reduce the wate...

Page 17: ...ience 2 1 1 Increase the flow rate 2 1 2 Blocked sprayhead clean or replace sprayhead 2 2 1 Check if stop valves are fully open Check if blockage in inlet filter 2 3 1 Increase the flow rate 3 1 1 See Water too hot causes 2 1 2 2 and 2 3 and their appropriate actions If it continues contact Triton Customer Experience 4 1 1 Reduce the flow rate 4 2 1 Is water supply mains or tank fed 4 2 2 If tank ...

Page 18: ...ait until the water pressure resumes to normal 6 1 1 Clean or replace blocked spray rings in the sprayhead and then fit new PRD Note Identify cause of operation before fitting new PRD unit When fitting a new PRD follow the commissioning procedure 7 1 1 See page 8 Siting of the Unit eliminate direct sunlight from the IR sensor 7 2 1 limit the highly reflective clothing to the unit Infrared sensors ...

Page 19: ...All our electric products are labelled accordingly with the crossed out wheeled bin symbol This indicates for disposal purposes at end of life that these products must be taken to recognised collection points such as local authority sites local recycling centres this will be free of any charges Do not return to Triton Showers To purchase a genuine Triton spare part for your product please visit ww...

Page 20: ...t should be made by credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information contained in the user guide Triton cannot accept liability for incorrect part identifica...

Reviews: