5  Unit varies from 
normal temperature 
to cold during use. 

6  Pressure relief 
device has operated 
(water ejected from 
PRD tube).

7  False Activation

5.1  Water pressure has 
dropped below minimum 
required 

6.1  Blocked sprayhead.

7.1   Direct Sunlight

7.2 High reflective 
clothing

5.1.1  Wait until the water pressure resumes to  
normal.

 
6.1.1  Clean or replace blocked spray rings in 
the sprayhead and then fit new PRD.

Note: Identify cause of operation before 
fitting new PRD unit. 
When fitting a new PRD, follow the 
commissioning procedure.

7.1.1   See page 8 - Siting of the Unit, eliminate  
direct sunlight from the IR sensor.

7.2.1 limit the highly reflective clothing to the 
unit. Infrared sensors are sensitive to highly 
reflective clothing. 

FAULT FINDING

Problem  

     Cause 

 

  Action

Summary of Contents for INSTAFLOW T30IR

Page 1: ...CE The swivel arm supplied with this product is a safety critical part of your shower Failure to use genuine Triton parts may cause injury and invalidate your guarantee FOR YOUR SERVICE REFERENCE NOTE DOWN THE PRODUCT CODE BELOW FROM THE FRONT OR TOP OF THE BOX ALTERNATIVELY REGISTER BY TEL 024 7637 8321 T30IR INSTAFLOW Handwash REGISTER ONLINE ENTER A PRIZE DRAW WIN 100 LOVE2SHOP VOUCHERS VISIT O...

Page 2: ...nd never fit any additional device to restrict the water outlet flow The outlet must not be connected to any tap or fitting other than those specified This appliance is intended to be permanently connected to the water mains and not connected by a hose set Mains water pressure only Minimum inlet pressure 100kPa 1 bar Maximum inlet pressure 1000kPa 10 bar This book contains all the necessary fittin...

Page 3: ...handwash unit as heat can transfer along the pipework and damage components 2 4 DO NOT fit any form of outlet flow control as the outlet acts as a vent for the heater can 2 5 DO NOT use excessive force when making connections to the swivel arm or sprayhead finger tight is sufficient 2 6 All plumbing connections must be completed before making the electrical connections 2 7 This appliance MUST NOT ...

Page 4: ...n top of the unit Liquid could seep through the joint between the cover and back plate and possibly damage the sealing rubber If water becomes too hot and you cannot obtain cooler water first check that the sprayhead is not blocked Secondly leave the product for 5 minutes and run the cycle again INTRODUCTION This book contains all the necessary fitting and operation instructions for your T30IR Ins...

Page 5: ...nit 8 Fitting the unit to the wall 9 Plumbing connections 10 Electrical connections 11 Fitting the swivel arm and cover 12 Commissioning 13 Operating the handwash 14 Operating functions 15 Cleaning 16 Flow rates and temperatures 16 Fault finding 17 18 Spare parts 19 Guarantee service policy etc rear cover PRODUCT FICHE Model 3 0kW Load Profile XXS Energy Efficiency Class A Energy Efficiency 38 Ann...

Page 6: ...rcoswitch 5 Stabiliser valve 6 Pressure Relief Device PRD 7 Can assembly 3kW 8 Thermal Cut Out TCO 9 Outlet pipe 10 PCB 11 Commissioning block 12 Cover Package Contents Handwash unit Cover screw pack 200mm swivel arm Instruction booklet including guarantee 7 8 4 1 2 5 9 6 3 Fig 1 Entry Points Key Water Entry Point Cable Entry Points 10 12 11 ...

Page 7: ...ig 2 within the unit 2 Before making any sort of electrical connection within the installation make sure that no terminal is live If in any doubt switch off the whole installation at the consumer unit 3 The 3kW rated handwash can be connected to a ring main via a 13A fused spur 3 1 The electrical supply must be adequate for the loading of the unit and existing circuits 4 A 30mA residual current de...

Page 8: ...ting compounds on any pipe fittings for the installation Isolating stopvalve Mains water supply Handwash Diagrammatic view not to scale Fig 3 Pressure Relief Safety Device A pressure relief device PRD is designed into the handwash unit which complies with European Standards The PRD provides a level of appliance protection should an excessive build up of pressure occur within the unit DO NOT operat...

Page 9: ...or the mains water is at the bottom Entry for electrical supplies are at the top bottom or back of the unit If top or bottom entry position is chosen the cable entry not being used should have the pipe trim inserted fig 4 Procedure Position the unit on the wall and using the backplate as a template mark the two fixing holes fig 5 Drill and plug the wall An appropriate drill bit should be used If t...

Page 10: ...any debris within the inlet pipe work Procedure Turn off the water supply either at the mains stop valve or the isolating stop valve Make sure the filter is inserted in the pipe before connection This helps to prevent ingress of debris fig 6 Connect the mains water supply to the inlet of the unit via 15mm pipe using the nut and olive supplied fig 7 Check the backplate is square on the wall and the...

Page 11: ... can only be from rear Route the cable into the unit and connect to the terminal block fig 9 as follows Earth cable to terminal marked Neutral cable to terminal marked N Live cable to terminal marked L IMPORTANT When connecting the cable fully tighten the terminal block screws and make sure that no cable insulation is trapped under the screws loose connections can result in cable overheating Make ...

Page 12: ...ature control so that it points at the position fig 12 Replace the cover squarely to the backplate and guide into position so that the control locates correctly into the splined spindle Should any difficulty arise recheck the points above Secure the cover in position with the two retaining screws at the top and bottom of the unit Fig 12 Fig 11 Fig 13 IMPORTANT PLEASE ENSURE COVER SCREWS ARE FULLY ...

Page 13: ...ontrol fully anti clockwise to the maximum flow position fig 12 When a smooth flow of water is obtained rotate the control from minimum to maximum and back again several times to release any trapped air If you are unable to do this during the 30 second timescale please run a second commissioning cycle by again passing your hand in front of the IR lens and once water flows repeat the process above ...

Page 14: ... slowly clockwise fig 18 NOTE There will always be a short time delay between selecting a flow rate and reaching the stable temperature for that flow rate To stop the handwash unit The unit will time out after 30 seconds Alternatively place hand in front of the sensor to turn the unit off Fig 18 5 15cm Activation Range Fig 17 WARMER COOLER WARNING DO NOT TOUCH THE LED PROTECTIVE SHEILDS REMOVING O...

Page 15: ...TARTS HERE dip switch for IR fitting book dip switch for IR fitting book DRAWING CHECKED BY CONTACT design_files tritonshowers co uk WRAS CHECKED BY PART STATUS Triton is a division of Norcros Group Holdings Limited Triton Showers Triton Road Nuneaton Warwickshire UK CV11 4NR TEL 024 7634 4441 FAX 024 7632 4424 www tritonshowers co uk cm IMPORTANT COMPONENT MUST COMPLY WITH ROHS DIRECTIVE 2011 65 ...

Page 16: ...ched to the handwash unit DO NOT use powerful abrasive or solvent cleaning fluids when cleaning the sprayhead assembly as they may damage the plastic fittings The sprayhead is a critical part of the unit In order to maintain maximum performance the sprayhead assembly should be cleaned at regular intervals to prevent build up of deposits from the water supply Blocked spray holes can reduce the wate...

Page 17: ...ience 2 1 1 Increase the flow rate 2 1 2 Blocked sprayhead clean or replace sprayhead 2 2 1 Check if stop valves are fully open Check if blockage in inlet filter 2 3 1 Increase the flow rate 3 1 1 See Water too hot causes 2 1 2 2 and 2 3 and their appropriate actions If it continues contact Triton Customer Experience 4 1 1 Reduce the flow rate 4 2 1 Is water supply mains or tank fed 4 2 2 If tank ...

Page 18: ...ait until the water pressure resumes to normal 6 1 1 Clean or replace blocked spray rings in the sprayhead and then fit new PRD Note Identify cause of operation before fitting new PRD unit When fitting a new PRD follow the commissioning procedure 7 1 1 See page 8 Siting of the Unit eliminate direct sunlight from the IR sensor 7 2 1 limit the highly reflective clothing to the unit Infrared sensors ...

Page 19: ...All our electric products are labelled accordingly with the crossed out wheeled bin symbol This indicates for disposal purposes at end of life that these products must be taken to recognised collection points such as local authority sites local recycling centres this will be free of any charges Do not return to Triton Showers To purchase a genuine Triton spare part for your product please visit ww...

Page 20: ...t should be made by credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information contained in the user guide Triton cannot accept liability for incorrect part identifica...

Reviews: