Advanced 15/55 amp selectable, 3-stage battery charger and selector switch for gel or wet cell batteries

Switch allows user to select between off, auto-invert and charge-only settings

6 diagnostic LEDs indicate AC present, on battery, overload, & battery voltage level (high, medium, & low)

Configuration switches to allow the user to select the high and low voltage for the unit to automatically transfer from AC power to battery

backup

Coated internal circuit boards offer continuous operation in humid environments (0-95%, non condensing) 

RJ45 port allows connection of remote switch (part# External switch for wired remote control of APS unit (

APSRM4

) which is included

Included remote switch can be linked in a daisychain with a second remote switch (sold separately) for remote operation from multiple

locations. Multiple mounting options include recess panel mount or below dash.Ignition interlock feature can shut down unit when engine is

off, ending worries of accidental battery drain

Allows unlimited runtime capability by allowing the use of any number of user-supplied batteries

Specifications

OUTPUT

Frequency
compatibility

60 Hz

Output watts

Continuous - 1000 watts, Overpower (up to 1 hour) - 1500 watts, Double-Boost wattage (up to 10 seconds) - 2000 watts

Output nominal
voltage

AC OUTPUT: 120VAC nominal, DC CHARGER OUTPUT (DC): 12VDC nominal

Output voltage
regulation

LINE POWER (AC): Maintains 120V nominal sine wave output. INVERTER POWER (AC): Maintains PWM sine wave
output voltage of 120 VAC (+/-5%). DC CHARGER OUTPUT (See battery recharge rate section)

Output frequency
regulation

60 Hz (+/- 0.3 Hz)

Overload
protection

Includes 12A input breaker dedicated to the charging system and 12A output breaker for AC output loads

Outlet quantity /
type

Includes 2 hospital-grade AC outlets with built-in GFI protection (NEMA 5-15R)

INPUT

Recommended
Electrical Service

DC INPUT: Requires 12VDC input source capable of delivering 95A for the required duration (when used at full
continuous capacity). For automotive applications, professional hardwire installation with 225A minimum battery system
fusing is recommended. A

Maximum input
amps / watts

DC INPUT: Full continuous load - 95A at 12VDC. AC INPUT: 12 amps at 120VAC with full inverter and charger load

Input connection
type

DC INPUT: 175A Anderson DC connector. AC INPUT: NEMA 5-15P hospital-grade input plug

Voltage
compatibility
(VAC)

120

Voltage
compatibility
(VDC)

12

BATTERY

Expandable
battery runtime

Runtime is expandable with any number of user supplied wet or gel type batteries

DC system
voltage (VDC)

15

Battery charge

Includes selectable 14 / 55 amp DC charging system with selectable profiles for vented wet cell and sealed gel cell
batteries. Optional use battery equalize charge function equalizes the charge level when used with multiple batteries
(see manual for detailed charger information).