d) After setting the parameters, press the SET button or pull the
trigger to return to the HOLD interface. The Auto Interval icon will
flash. When the start time of the scheduled measurement is reached,
the thermometer will automatically start temperature measurement
and store the current time and measured value. Each time the
interval time is reached, the thermometer will automatically measure
and store the current data, until the last interval.
3. In the HOLD interface, press the LOG button for 3s to enter the
scheduled measurement log value query mode. The screen will
display the Auto Interval icon, the LOG icon and the log group
number. In this mode, press the
or
button to query the
measured temperature value corresponding to the scheduled time,
press the LOG button for 10s to delete all storage values of the
scheduled measurement, and short press the LOG button or pull the
trigger to exit.
System Time Setting
In the HOLD interface, press the SET button for 3s to enter the lock
measurement setting interface, and short press the SET button twice
to enter the system time setting interface. Short press the LOG