25
Triple Solar assembly instruction PVT heat pump panels March 2020
9. Finishing a pitched roof
For pitched roof installations Triple Solar supplies a cover plate to cover the piping along the heat pump
panels. This cover plate cannot be mounted on PV panels.
art. nr.
product
specification
number
360402
piping cover plate
aluminium, black coating
1x
320101
mounting rail cover
aluminium, black anodising
2x
336101
Self-drilling screw with EPDM ring
4,8x25mm stainless steel
(SW8)
4x
Instructions
: (see corresponding images below)
1.
Slightly bend the mounting rail cover by squeezing the sides together.
2.
Slide the cover over the mounting rail.
3.
Secure the cover to the rail using a self-drilling screw (SW8).
4.
Fix the set edge of the cover plate in the recess of the heat pump panel side frame.
5.
Secure the cover plate to the head of the mounting rail using a self-drilling screw (SW8).
6.
Repeat steps 1 through 5.