nanoFlu
1.3 Warnings
• This sensor has been developed for use in industry and science. It should only be used for the measure
-
ment of aqueous solutions, e.g. process waste water, river water or sea water.
•
Sensors made from stainless steel must be cleaned immediately after coming into contact with salt water
or other corrosive substances ( e.g. acids, alkalis, chlorine-based connections.
• The material resistance should be checked after every use.
• The sensor has seals made from NBR (nitrile butadiene rubber). Sealing rings made from other materials
may be used upon individual request. Before operation, please ensure that the measured medium does
not damage the seals.
• Do not cut, damage or change the cord. Make sure that no heavy objects are placed on the cord and that
the cord is not folded. Make sure that the cord is not run near hot surfaces.
• If the sensor cord is damaged, it must be replaced with an original part by the customer service of TriOS
Mess- und Datentechnik GmbH or by an authorized TriOS technician.
•
Do not place unsuitable items in front of the measuring window as long as the measurement process is
running, as this can cause damage to the sensor or incorrect measurement results.
• Stop operation of the sensor in the event of excessive heat development (i.e. if it is hot to the touch).
Switch off the sensor immediately and unplug the power cord from the power supply. Please contact your
dealer or TriOS customer service.
• Never try to disassemble or modify a part of the sensor if such a procedure is not explicitly described in
this manual. Inspections, modifications and repairs may only be carried out by the dealer or by qualified
experts authorized by TriOS.
Devices from TriOS Mess- und Datentechnik GmbH meet the highest safety standards. Repairs to the
device (which involve the replacement of the connecting cable) must be carried out by TriOS Mess- und
Datentechnik GmbH or by a workshop authorized by TriOS. Faulty, improper repairs can result in accidents
and injuries.
1.4 Users and Operating Requirements
The nanoFlu fluorometer has been developed for use in industry and science. The target group for the opera
-
tion of the nanoFlu fluorometer is technically skilled staff in plants, sewage treatment plants, water plants and
institutes. The use of this device often requires the handling of hazardous substances. We assume that the
operating personnel are familiar with dealing with dangerous substances based on their professional training
and experience. The operating personnel must be able to correctly understand and implement the safety labels
and information on the packaging and in the package inserts of the test kits.
1.5 Intended Use
The purpose of the nanoFlu is exclusively the implementation of fluorescence measurements as described in
this manual. For this purpose, the fluorometer is an immersion sensor, which is used underwater or with flow
cells. Please note the technical data of the accessory parts. Any other use is not considered to be in compliance
with the intended use.
Stainless steel sensors are not intended for use in sea water or in high chloride
concentrations (corrosion). Only sensors made of titanium can be used in these
cases.
NOTICE
TriOS does not guarantee the plausibility of the measured values. The user is always respon-
sible for the monitoring and interpretation of the measured values.