Comfort
BREEZE
TM
Model CB707
I n s t a l l a t i o n , O p e r a t i o n , & M a i n t e n a n c e M a n u a l
9
www.trioniaq.com
Figure 9
Figure 10
6. Maintenance & Troubleshooting
DANGER - RISK OF ELECTRIC SHOCK
Before cleaning, servicing, or parts replacement, the unit must
be disconnected from all sources of electricity.
6.1 Cleaning Instructions
It will become necessary to clean your humidifier as time goes
on. A red LED Service indicator light may light up. (Refer to
#3 in Control Board Faults Section, 1500 hour service interval.)
This will tell you that it is time to service your humidifier. Please
follow the following procedure.
1.
Perform the End-Of-Season Decommisioning procedure
described in section 5.3. This will cause the unit to run
out of water so that service can be performed without a
large amount of water inside the unit.
2.
Adjust Humidistat to the lowest setting to ensure that
there is no call for humidity.
3.
Unplug the humidifier in order to remove power before
servicing the unit.
4.
Close the water supply valve so that no water may flow to
the humidifier and remove the supply line from the push-
to-lock fitting. See section 4.3 Step 3 for details regard-
ing removing the tube from the fitting.
5. Remove the top discharge dome and wipe out any ac
-
cumulated mineral build-up.
6. Examine the atomizing posts and gently clean any min
-
eral build-up from the posts using a soft cloth. Ensure
great care is taken not to damage, bend, or break the
atomizing posts.
7.
Remove the cover from the electrical box and unwire the
line cord and humidistat wires from the terminals. It is not
necessary to remove the strain releif fittings.
8.
On either side of the circuit board there are mounting
screws. Remove the screw that secures the ground wire
(left). Loosen the screw on the right. It is not necessary
to remove it completely. (See Figure 9)
9. With the dome removed from the unit, remove the four
screws that secure the motor base to the reservoir base.
(See Figure 10)
10.
The mid-section of the humidifer may now be lifted from
the base. This will allow access to the water reservoir,
impeller pump, solenoid valve, float switch, control enclo-
sure and air filter media. The circuit board will slide out
with the mid-section of the unit.
11.
Examine the float switch and ensure that it moves freely
upon the shaft. If there is any binding, gently clean the
shaft to allow the float to move freely.
12.
Wipe away any additional mineral build-up that may have
accumulated elsewhere within the humidifier.
13.
Examine filter media and remove and clean as necessary
using a mild soap and water solution. Allow to dry and
reinstall between vent holes and pinch pins.
14.
Reassemble the humidifier in the reverse of disassem-
bly. Assembly may be simplified by turning the humidifier
upside-down. This will simplify the alignment of the cir-
cuit board with the grooves on either side of the electrical
compartment.
15.
Reset the service timer (RED LED) by cycling the hu-
midistat on & off three times within 10 seconds. Return
to service.