1. Warranty

Humidifier 5-Year Limited Warranty

This limited warranty covers Trion Residential Type Humidifiers, exclud-

ing duct work, wiring and installation. Trion warrants that all new Trion 

humidifiers  are  free  from  defects  in  material  and  workmanship  under 

normal,  non-commercial  use  and  service. Trion  will  remedy  any  cov-

ered defects if they appear within 60 months from the date of original 

installation & subject to the terms and conditions of this Limited 5-Year 
Warranty stated below:

1. 

THIS LIMITED 5-YEAR WARRANTY is granted by Trion Customer 

Service, 101 McNeill Road, Sanford, NC 27330.

2. 

This warranty shall extend only to any non-commercial owner who 

has purchased the residential humidifier other than for purposes 

of resale.

3. 

All  components  are  covered  by  this  limited  warranty  except  ex-

pendable items, such as evaporative pads, media filter pads and 

nozzles.

4. 

If, within the warranty period, any Trion residential humidifier unit or 

component requires service it must be performed by a competent 

heating and/or air conditioning contractor (preferably the installing 

contractor). Trion will not pay shipping charges, or labor charges to 

remove or replace such defective parts or components. If the part 

or component is found by inspection to contain such defective ma-

terial and workmanship it will be either repaired or exchanged free 

of charge at Trion’s option, and returned freight collect.

5. 

In order to obtain the benefits of this limited 5-year warranty, the 

owner must notify the dealer or distributor of any defect within 30 

days of its discovery. If after reasonable time you have not received 

an adequate response from the dealer or distributor, notify in writ-

ing to Trion Customer Service 101 McNeill Road, Sanford, NC 

27330, or call 1-800-884-0002 or email customerservice@trioniaq.

com Humidifiers which have been installed or become part of real 

estate cannot be returned. Trion will receive, freight prepaid, only 

removable parts or components of such defective humidifiers.

6.  This limited warranty does not apply to any part or component that 

is damaged in transit or in handling, has been subject to misuse, 

neglect or accident; has not been installed, operated and serviced 

according  to Trion’s  instructions;  has  been  operated  beyond  the 

factory rated capacity; or altered in any such way that its perfor

-

mance is affected. There is no warranty due to neglect, alteration 

or ordinary wear and tear. Trion’s liability is limited to replacement 

of defective parts or components and does not include the pay

-

ment of the cost of labor charges to remove or replace such defec-

tive components or parts.

7. 

Trion will not be responsible for loss of use of any product; loss 

of time, inconvenience, or any other indirect, incidental or conse

-

quential damages with respect to person or property, whether as a 

result of breach of warranty, neglect or otherwise. SOME STATES 

DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCI

-

DENTAL OR CONSEQUENTIAL DAMAGES, SO THE LIMITA

-

TION  OR  EXCLUSION  IN  THE  PRECEDING  SENTENCE  MAY 

NOT APPLY TO YOU. 

8. 

THIS  WARRANTY  GIVES  YOU  SPECIFIC  RIGHTS, AND  YOU 

MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE 

TO STATE.

9. 

Any warranty by Trion of merchantability, fitness for use or any oth-

er warranty (express, implied or statutory), representation or guar

-

antee other than those set forth herein, shall expire at the expira

-

tion date of this express limited warranty. SOME STATES DO NOT 

ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY 

LASTS, SO THE LIMITATION IN THE PRECEDING SENTENCE 

MAY NOT APPLY TO YOU.

10.  Trion reserves the right to make changes in the design and material 

of its products without incurring any obligation to incorporate such 

changes in units completed on the effective date of such change.

2. Safety & Warnings

DANGER

RISK OF ELECTRIC SHOCK

Before cleaning, servicing, or parts replacement, the unit must 

be disconnected from all sources of electricity.

CAUTION

Read these instructions thoroughly before installing this unit.  
Check  data  label  and  verify  electrical  specifications  agree 

with those at the point of installation.

WARNING

Improper installation, adjustment, alteration, service, or main-
tenance may cause property damage, injury, or death.  This 
appliance must be installed according to these instructions.  
Read these instructions thoroughly before installing or servic-

ing the unit.

WARNING

Failure to install this unit in a position that is level and plumb 
may impair the unit’s ability to drain if an overflow condition 

presents itself.  Damage to personal property may also result.

WARNING

Installation in freezing conditions can result in unit failure. 
Damage to personal property may also result.  

WARNING

This appliance is not intended for use by children or persons 
with reduced physical, sensory or mental capabilities, or lack 
of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by 
a person responsible for their safety.  Children should be su-

pervised to ensure that they do not play with the appliance.

WARNING

A drain pan should be installed under the unit and any supply 

water / drain connections to prevent damage to property in the 
event of a water leak or faulty operation.

Summary of Contents for ComfortBREEZE CB707

Page 1: ...T r i o n w w w t r i o n i a q c o m ComfortBREEZE TM CB707 Centrifugal Atomizing Humidifier READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...4 3 3 What s in the Box 4 3 4 Hardware Details 4 4 Installation 5 4 1 Clearances 5 4 2 Selecting a location 5 4 2 1 Wall Mounting 5 4 2 2 Duct Mounting 6 4 2 3 Ceiling Mouning 6 4 2 4 Shelf Mounting...

Page 3: ...is limited to replacement of defective parts or components and does not include the pay ment of the cost of labor charges to remove or replace such defec tive components or parts 7 Trion will not be r...

Page 4: ...f the air If applicable set the humidistat in the recommended range of 30 40 relative humidity for automatic humidity control during the heating season A lower setting may be necessary to pre vent con...

Page 5: ...ic dispersion it may be hung from a ceiling mounting hardware not included for this type of installation or it may be simply mounted to a shelf An indicating LED is located on the oposite side of the...

Page 6: ...ounting holes as shown on the template for mounting the bracket to the duct 5 Cut out the discharge hole while taking care not to injure yourself Once the hole is cut out ensure that the edges will no...

Page 7: ...ge the water into a bucket or pan This will allow the water to flush any debris that may have accumulated in the line during the in stallation process Once this is complete close the saddle valve 3 At...

Page 8: ...up for continu ous operation by installing a jumper between the H terminals on the control board you must remove the jumper wire placed between terminals H1 H2 on the control board 5 3 End of Season...

Page 9: ...at care is taken not to damage bend or break the atomizing posts 7 Remove the cover from the electrical box and unwire the line cord and humidistat wires from the terminals It is not necessary to remo...

Page 10: ...logged solenoid valve or flow restrictor c Leaking reservoir d Bad control board 2 Red LED blinking repeatedly 1 second On 1 second OFF Unit will not function B Float switch not closing in 30 minutes...

Page 11: ...ler tube Motor will not operate turn Motor internal thermal protective device is open Remove power and allow motor to cool Restart unit and ensure proper operation If motor will not turn replace motor...

Page 12: ...1 19 G 109 G 109 SOLENOID VALVE ASSEMBLY 1 20 165001 001 PUSH TO LOCK MALE ELBOW 1 4 X 1 8 NPT 1 21 265305 001 FILL FITTING 1 8 NPT 2 22 166129 001 SCREW 8 X 3 8 PH PH THRD CUT SST 7 23 265378 220 SC...

Page 13: ...SHOWN 2 54 266793 001 FEMALE THREADED STANDOFF 1 55 266455 001 CONTROL BOARD BRACKET RH 1 56 266455 002 CONTROL BOARD BRACKET LH 2 57 266792 001 LOCKNUT PG9 1 58 266826 001 INLET RING 1 59 265442 001...

Page 14: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 14 www trioniaq com See Note 2 on page 13...

Page 15: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 15 www trioniaq com...

Page 16: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 16 www trioniaq com...

Page 17: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 17 www trioniaq com...

Page 18: ...Form No 265631 001 rev 01 15 2013 Trion 2013 All Rights Reserved Trion 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com...

Reviews: