![Trinamic TMCM-3314 Firmware Manual Download Page 24](http://html1.mh-extra.com/html/trinamic/tmcm-3314/tmcm-3314_firmware-manual_1163074024.webp)
TMCM-3314 TMCL
™
Firmware Manual • Firmware Version V1.11 | Document Revision V1.10 • 2019-JAN-25
24 / 144
3.6.3
MST (Motor Stop)
The motor is instructed to stop with a soft stop.
Internal function:
The velocity mode is selected. Then, the target speed (axis parameter #0) is set to zero.
Related commands:
ROR, ROL, SAP, GAP.
Mnemonic:
MST
<
axis
>
Binary Representation
Instruction
Type
Motor/Bank
Value
3
0
0. . . 2
0
Reply in Direct Mode
Status
Value
100 - OK
don’t care
Example
Stop motor 0.
Mnemonic:
MST 0.
Binary Form of MST 0
Field
Value
Target address
01
h
Instruction number
03
h
Type
00
h
Motor/Bank
00
h
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
00
h
Value (Byte 0)
00
h
Checksum
04
h
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at