TMCM-170 and TMCM-171 MODULE – Reference and Programming Manual
12
Copyright © 2005, TRINAMIC Motion Control GmbH & Co. KG
3.1.3 MST - Motor Stop
Description:
This instruction stops the motor softly by switching off the drivers.
Internal function:
the axis parameter "target velocity" is set to zero.
Related commands:
ROL, ROR, SAP, GAP
Mnemonic:
MST <motor number>
Binary representation:
INSTRUCTION NO.
TYPE MOT/BANK
VALUE
3
(don't care)
<motor number>
(don't care)
Example:
Stop motor #0
Mnemonic:
MST 0
Binary:
Byte Index
0
1
2
3
4
5
6
7
8
Function
Target-
address
Instruction
Number
Type Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Checksum
Value (hex)
$01 $03 $00
$00
$00 $00 $00 $00 $04