background image

FEATURES – FUNCTION 

FUNCTION 

BUTTON 

DESCRIPTION 

SET DISPENSING 

PERIOD 

Select one of the six different dispensing rates (1M,
2M, 3M, 6M, 12M and Half Month)
The dispensing rate can be changed during
operation.

POWER ON/OFF 

Depress the button for 2 seconds to turn unit on

and off.

Default setting is 1 Month using the 125cc pouch.

GREASE VOLUME 

SELECTION 

Select the volume of grease pouch (125cc/250cc).

TEST 

MODE 

The test function is provided to confirm that the unit 
works prior to installation or after replacement of 
service pack. In addition, the test function is provided 
for troubleshooting purposes if the motor has been 
overloaded.  

IMPORTANT : 

To activate TEST MODE, depress the button for 2 
seconds.  “tst” should start blinking and an audible 
gear mesh sound will confirm unit operation and a 
grease discharge should be observed.  If the unit 
does not operate in Test Mode, it should be returned 
to your supplier. 
To deactivate TEST MODE, depress the button. The 
unit will then stop functioning in TEST MODE within 20 
seconds.  Otherwise, the unit will automatically stop 
TEST MODE after 2 minutes and be back to previous 
mode set. 

RESET 

RESET 

Use when service pack is replaced.
Use to reset unit back to its default setting

following ; 

- Abnormal display on LCD screen.
- A unit malfunction or when the Power ON/OFF

button is not available.

CAUTION! 

Depressing RESET will 

eliminate

 all previous 

settings and records.   

WARNING LAMP 

RED LED 

For Low battery power, Motor overload, or Low grease 
level, the red LED will blink periodically. 

NOTE: 
Whenever any function is selected, the red LED should blink once only. 

      Page 6/11 

Summary of Contents for STREAMLINER M

Page 1: ...Grease Dispenser Streamliner STREAMLINER M USER MANUAL TRICO CORPORATION Page 1 11 ...

Page 2: ...peration and proper installation of the STREAMLINER M unit we strongly recommend that you read the following information carefully before use If you require further information please contact your local supplier COMPONENTS A STREAMLINER M package contains CONTROL PANEL SPRING HOLDER SPRING PRESSURE PLATE LOCK BATTERY PACK Main Unit Top view Main Unit Front view Top Cover Assembly Page 2 11 ...

Page 3: ...CH BATTERY PACK EXTERNAL STICKER DUST COVER 250cc GREASE POUCH BATTERY PACK EXTERNAL STICKER DUST COVER Grease Type Date Installed Date Expiry Grease Type Date Installed Date Expiry Unit Assembled STREAMLINER M USER MANUAL Page 3 11 ...

Page 4: ...the pouch will empty over a period of 1 month approx 4 2cc day for a 125cc pouch and 8 3cc day for a 250cc pouch 2M means the grease pouch will empty over a period of 2 months approx 2 1cc day for a 125cc pouch and 4 2cc day for a 250cc pouch etc See Dispensing Recommendation on page 9 The dispensing rate can also be changed during operation Depress the button for 2 seconds to turn unit on and off...

Page 5: ...r DAYS AFTER DISPENSING COMPLETION EXPIRE S XX indicates the number of days since the lube cycle has been completed or the grease pouch has become empty S denotes Stop DISPENSING TEST MODE Indicates test mode is activated tst denotes Test LOW BATTERY POWER Indicates low battery power MOTOR OVERLOAD Indicates motor overloaded and the unit has stopped functioning LOW GREASE LEVEL Indicates that the ...

Page 6: ...st should start blinking and an audible gear mesh sound will confirm unit operation and a grease discharge should be observed If the unit does not operate in Test Mode it should be returned to your supplier To deactivate TEST MODE depress the button The unit will then stop functioning in TEST MODE within 20 seconds Otherwise the unit will automatically stop TEST MODE after 2 minutes and be back to...

Page 7: ...T MODE procedure Depress TEST button the unit displays tst and start to discharge grease The unit will continuously operate in purge mode until the TEST button is depressed To deactivate TEST MODE depress the button The unit will stop functioning in TEST MODE within 20 seconds Otherwise the unit will automatically stop TEST MODE after 2 minutes and be back to previous mode set 5 To set a required ...

Page 8: ...the unit The SERVICE PACK is supplied as one kit and comes in boxes of 20 for both 125 and 250cc SERVICE PROCEDURE 1 2 3 4 5 6 7 8 9 10 11 Remove external dust cover Turn the unit off Remove top cover Caution Cover is spring loaded Remove and dispose the used grease pouch battery pack and external dust cover in accordance with local regulations Insert a new battery pack as per the installation pro...

Page 9: ...TERY PACK Store BATTERY PACK in a cool and dry place Prevent impact damage Ensure operating environment meets requirements MOTOR OVERLOADED Over lubrication occurring Grease blockage Excessive back pressure Extreme operating temperature e g exceeds 15 60 5 140 Confirm correct dispensing rate Run TEST MODE for excessive back pressure determine cause and rectify IMPORTANT If the RESET is activated d...

Page 10: ...er 125cc Dispensing Equivalents 250cc Dispensing Equivalents 121 305mm 4 3 4 12 Half month 16 6cc day 105 120mm 4 1 8 4 3 4 Half month 8 3cc day 1 month 8 3cc day 88 104mm 3 1 2 4 1 8 1 month 4 2cc day 2 month 4 2cc day 79 87mm 3 1 8 3 1 2 2 month 2 1cc day 3 month 2 8cc day 63 78mm 2 1 2 3 3 month 1 4cc day 6 month 1 4cc day 49 62mm 2 2 1 2 6 month 0 7cc day 12 month 0 7cc day 25 48mm 1 2 12 mont...

Page 11: ...for application where a constant cold temperature exists Dispensing Rate 1 2 3 6 12 and Half month Lube cycle approx 20 seconds stroke Dispensing volume 0 33 0 01 gram stroke 20 C equivalent to 0 350cc stroke for a grease of specific gravity 0 90 Dispensing Accuracy 3 20 C Output thread 3 8 NPT or BSP NOTE Technical information is subject to change without notice WARRANTY Trico Mfg Corp guarantees...

Reviews: