RED LED (WARNING)
Starts to blink when any of
the following conditions is
encountered:
Low battery power
Motor is overloaded
Low grease level
Other abnormal condition
Please verify the cause of
malfunction or failure.
RESET unit back
to default setting
BUTTONS
SELECT DISPENSING PERIOD
- Six different dispensing rates are available (1M, 2M,
3M, 6M, 12M and Half Month). 1M means that the
contents of the pouch will empty over a period of 1
month (approx. 4.2cc/day for a 125cc pouch and
8.3cc/day for a 250cc pouch). 2M means the grease
pouch will empty over a period of 2 months (approx.
2.1cc/day for a 125cc pouch and 4.2cc/day for a 250cc
pouch) etc…
☞
See “Dispensing Recommendation” on page 9.
- The dispensing rate can also be changed during
operation.
Depress the button for 2 seconds to turn unit on and off.
The default dispensing period setting is 1 month@125cc.
SELECT GREASE VOLUME (125cc or 250cc)
-
Select the volume of Grease pouch to be used.
- This button is also used for the TEST MODE.
Page 4/11