Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008
P a g e
14 | 20
9.
As the lubricant is being filled, check the Tank Viewports to avoid over-filling. Do not over fill the
system tank, this will cause damage to the Watchdog Desiccant Breather.
10.
To remove the remaining few gallons from the drum, tip the drum at approximately 30 degrees,
with the suction tube placed at the bottom most portion of the drum. The positive displacement
pump will completely evacuate all lubricant from the drum.
11.
When the drum, or container, is empty, lift the suction wand out of the drum and allow the
pump to pull any residual oil remaining in the hose out. Then turn the On/Off Switch to the
“OFF” position.
12.
Remove suction wand from empty drum, wipe dry and place in holder.
13.
On the Tank Manifold, close the valve to the tank (upper valves). This will prevent any access
lubricant in the hose system to drain into the Tank manifold. This step also helps with the
prevention of cross-contamination between lubricants on the next fill.
14.
Remove the static discharge cabling and dispose of the empty drum appropriately.
Note:
It is normal for air to be trapped inside the hoses during the initial filling of the
system. Once the air bubbles have passed thru the system, fluid should be dispensed
normally. If air bubbles continue to persist after initial fill, there may be a problem
with a fitting, connection, or hosing.
Dispensing Lubricant
1.
Place container on Dispensing Area below the correct tank Dispensing Nozzle.
2.
Pull Dispensing Nozzle handle towards you, away from the system, to allow lubricant to flow.
3.
Release Dispensing Nozzle handle and the flow will stop.
CAUTION:
Pinch Point possible when releasing dispensing Nozzle handle.
Dispensing Area
Dispensing Nozzle