32
If necessary, check the
setting with a spirit
level.
Never place
cardboard, wood or
similar materials under
the machine to
compensate for any
unevenness in the floor. Some vibration is
inevitable, especially if mounted on a wooden
floor.
Sprung wooden floors are particularly
susceptible to vibration. For advice, consult a
builder. If possible, always place the machine
on a solid floor.
Special conditions
If the floor is carpeted or covered with crumbly
or soft material, insert a rigid support base
under the feet to prevent noise, vibration or
displacement. The base should protrude a few
centimetres beyond the edges of the machine.
WARNING!
The machine should NOT be placed on deep
pile carpeting.
NOTE
Please ensure that when the appliance is
installed it is easily accessible for the engineer
in the event of a breakdown.
Water inlet
An inlet hose is supplied and can been found
inside the machine drum.
Do not use the hose from your previous
machine to connect to the water supply.
1. Open the porthole and extract the inlet
hose.
2. Connect the hose with the angled
connection to the machine.
Do not place the inlet hose downwards.
Angle the hose to the left or right depending
on the position of your water tap.
3.Set the hose
correctly by
loosening the ring
nut.
After positioning the
inlet hose, be sure to
tighten the ring nut
again to prevent
leaks.
4. Connect the hose to a tap with a 3/4”
thread. Always use the hose supplied with
the appliance. The inlet hose must not be
lengthened. If it is too short and you do not
wish to move the tap, you will have to
purchase a new, longer hose specially
designed for this type of use.
NOTE
Installation should
comply with local
water authority and
building
regulations’
requirements.
The appliance must be connected to a cold
water supply.
A minimum vertical water pressure of 0.05
MPa (0.5 bar) is required for safe operation of
the appliance.
If you cannot make the cold water connection
direct from the rising mains, you may be able
to operate the appliance from your cold water
storage system.
There should be a minimum vertical distance
of 5.02m (16.5 ft) between the appliance’s
inlet and the bottom of the water storage tank.
Water drainage
This appliance is designed to be permanently
plumbed into your home's drainage system
using one of the following methods.
1. Into a drainage standpipe.
45°
35°