Electrical/maintenance 

 

All electrical work to be carried out by competent persons using suitable materials for the 
application. 

 

Do not open the Tricel Puraflo alarm cover without firstly isolating the mains power. All 
power isolation switches should be turned off [Follow Lock-out/Tag-Out Procedure] 
before any maintenance/inspection work is done at the wastewater treatment plant. 

 

Never use electrical lights, appliances or power tools in or close to water or wet ground 
near the septic tank or percolation area. This can result in electrical shock or explosion. 

 

Electrical work must be carried out strictly to the manufacturer’s instructions and to the 
relevant national rules for electrical installations.  All connections to the control panel 
should only be made by competent qualified personnel. If a cable is damaged, it should 
be  replaced  immediately  to  prevent  electrical  shock  or  damage  to the  electrical 
equipment. All electrical connections are completed on site. 

 

When working with machinery/electrical equipment, proximity of water shall be noted. 
Electrical equipment shall not be wet when working with it. 

 

There is potential danger when de-sludging and therefore this shall never be done alone.  

 

A wastewater treatment system that fails to fully treat sewage due to poor 

maintenance or overloading may allow excess nutrients (phosphorus and nitrogen) to 

reach nearby lakes and streams, promoting algae and plant growth. Algal blooms and 

abundant weeds may make lakes unpleasant for swimming, boating, and other water-

based activities. This plant growth can also affect water quality for fish and wildlife 

habitat. As plants die and settle to the bottom, they are broken down by bacteria that use 

up oxygen that fish need to survive. 

 

It is the responsibility of the owner to ensure that the wastewater treatment plant is 

operated and maintained correctly at all times. 

 

It is advised that the owner enters into a yearly Service Agreement to ensure the correct 
operation of their wastewater treatment plant. 
 

1.3

 

Installation: 

 

Excavation work should be planned with due regard to health and safety requirements. 

 

Septic  tank should also be properly vented in accordance with the tank 

manufacturer’s  guidelines. 

 

Excavated material should either be shored or battered back to a “safe” angle. 

 

Use appropriate lifting equipment. 

 

Care should be taken around grounds work machinery. 

 

Keep proper footing and balance at all time. 

 

Tricel Puraflo modules are supplied with ropes for lifting purposes. The modules are 

designed for a single lift when placing them in position. 

 

 

 

 

 

 

Summary of Contents for Puraflo 1-50

Page 1: ...1 124 Rev 4 Jan 2019 Tricel Puraflo 1 50 Installation Wastewater Treatment Plants Engineering a green future...

Page 2: ...3 Tricel Puraflo systems 1 11PE max 4 modules 6 2 3 1 Puraflo module installation step by step guide 6 2 3 2 Septic tank effluent filter installation secondary treatment only 10 2 4 Tricel Puraflo sy...

Page 3: ...e wastewater treatment system must be appropriately trained Suitable protective clothing including waterproof abrasion resistantgloves overalls safetyfootwear eye earandrespiratoryprotection goggles f...

Page 4: ...udgingand thereforethisshallneverbe donealone A wastewater treatment system that fails to fully treat sewage due to poor maintenance or overloading may allow excess nutrients phosphorus and nitrogen t...

Page 5: ...cel Puraflo modules Suitably sized equipment will be required to excavate the hole and to lift the Tricel Puraflo system into place minimum 6 ton machine The Tricel Puraflo system should not be instal...

Page 6: ...uidelines 6 Install pump chamber as per manufacturer s guidelines Install Puraflo Modules 7 Excavate a hole that will allow for a minimum 275mm gravel base beneath the Puraflo modules taking note of w...

Page 7: ...the rising main must be dug from the pump chamber water treatment plant to the Puraflo modules inlet assembly We recommend a 300mm wide trench with a 650mm depth The rising main must be surrounded by...

Page 8: ...dge fits under the Tricel Puraflo modules and into the V shape between the modules 16 Install the remaining outer PVC pipes and connect them into sampling chamber Once the pipework has been connected...

Page 9: ...should be connected to this inlet assembly in single zone systems The rising main must be connected to the inlet of the indexing valve in multi zone systems The following images show the completed in...

Page 10: ...t only Secondary treatment Tricel Puraflo systems require an effluent filter be installed at the outlet of the septic tank o On sites in which complete secondary treatment systems i e septic tank AND...

Page 11: ...of the Vento septic tank 2 Glue the 200mm length 110mm 4 diameter sewer pipe to the outlet of Vento septic tank 3 Fit the euro reducer into the effluent filter Apply PVC sealant around the end of the...

Page 12: ...200mm 110mm pipe and push the effluent filter onto the pipe Secure the effluent filter using a self tapping screw in the location indicated by the arrow 3 To facilitate access to the effluent filter w...

Page 13: ...the pump chamber and the Puraflo modules 2 4 1 Indexing valve There are two types of indexing valve The indexing valve supplied is determined by the number of zones in the Tricel Puraflo system o 6 o...

Page 14: ...ve 2 Threaded pipe supplied with valve 3 Union nut 4 Union end 5 50mm length of 32mm pipe 6 40 32mm reducing bush 7 40mm elbow Note The elbow object 7 above can be orientated to suit the installation...

Page 15: ...bottom of the distribution box to suit the site conditions 5 Place the indexing valve into the distribution box connect the outlet pipes to Puraflo modules and inlet pipe from the pump chamber to the...

Page 16: ...n of The power supply SWA cable s must be suitably sized and comply with all national regulations and requirements The sizing of the cable is the responsibility of a qualified electrician A qualified...

Page 17: ...vice technician It is important Tricel commission the Tricel Puraflo system to verify that the system has been installed correctly and ensure that the Tricel Puraflo will achieve the required treatmen...

Page 18: ...18 This page is intentionally left blank...

Page 19: ...19 This page is intentionally left blank...

Page 20: ...ary 221361 1 62 4050 33P Puraflo Secondary 221349 1 98 4950 33P Puraflo Tertiary 221362 1 98 4950 42P Puraflo Secondary 221350 2 52 6300 42P Puraflo Tertiary 221363 2 52 6300 45P Puraflo Secondary 221...

Reviews: