Revision: 0
FlexxPump4 D
User Manual
17
EN-
5.4
FP4 D423 / FP4 D223
In the FP4 D423 or FP4 D223, the theoretical two outlets of the first pump body are
internally combined into one outlet 1.1. One outlet is supplied with 0.16cm³ lubricant per
stroke. The outlets are supplied with lubricant one after the other.
The FP4 D423 or FP4 D223 allows you to set dosing volume differences from outlet 1.1
to outlets 2.1 and 2.2 by controlling the two pump bodies individually. An explanation of
the different control signals can be found in chapter 8.2.
If the two pump units are controlled equally, outlet 1.1 is supplied with twice the
amount of lubricant of outlets 2.1 or 2.2, due to the internal combination of the outlets of
the first pump unit.
Number of pump units
2
Number of outlets
3
Differences in dosing volume per
pump unit possible
yes
Maßstab/Scale
Benennung / Title
Material
Name
Datum/Date
Warengruppe
Zeichnungsnr. / Drawing no.
Blatt/Sheet
Gewicht/Weight
Toleranzen / Tolerances: ISO 2768-1 m K
Schaumstoffteile nach DIN 7715 Teil 5 Klasse P2
Dieses Dokument ist Eigentum von: This document is ownership of:
3/3
FlexxPump 402_ZOF
Bearb.
Gepr.
Änd./Index
a
J. Niederg.
J. Niederg.
1:1,5
DIN A4
Maße in mm
VK-Artikel-Nr.
Zust.
Änderung
Datum Name Gepr.
FlexxPump 402
21.11.2017
21.11.2017
Maßstab/Scale
Benennung / Title
Material
Name
Datum/Date
Warengruppe
Zeichnungsnr. / Drawing no.
Blatt/Sheet
Gewicht/Weight
Toleranzen / Tolerances: ISO 2768-1 m K
Schaumstoffteile nach DIN 7715 Teil 5 Klasse P2
Dieses Dokument ist Eigentum von: This document is ownership of:
3/3
FlexxPump 402_ZOF
Bearb.
Gepr.
Änd./Index
a
J. Niederg.
J. Niederg.
1:1,5
DIN A4
Maße in mm
VK-Artikel-Nr.
Zust.
Änderung
Datum Name Gepr.
FlexxPump 402
21.11.2017
21.11.2017