3. TECHNICAL INFORMATION
BOILER MODEL
TRG 45
TRG 60
TRG 80
Heat Output
kW
13.2
17.6
23.5
Btu/h
45,000
60,000
80,000
*Radiator Surface
m
2
21
30
42
ft
2
230
325
450
Max. Burning Rate
kg/h
2
2.5
3.4
lb/h
4.5
5.5
7.5
Hopper Capacity
kg
30
37
41
lb
67
82
91
Weight
kg
120
150
196
lb
266
330
435
Water Capacity
litres
34
40
48
gal.
7.5
8.8
10.6
Forced Draught Fan
230 volt 50Hz
Watts
24
24
35
Water Connections
(two flow, two return)
in. BSP
1
1
1
Flue Outlet Socket
for BS Flue-pipe
in
5
5
5
Maximum Working head
15.8m (52ft)
Thermostat
Adjustable between 55° C and 82° C in six settings.
Casing
White stove enamel with two tone grey facia.
Insulation
Glass fibre lining in side panels.
Draught Stabiliser
Integral part of boiler
*Based on 160 Btu/h/sq. ft/100 F difference. An allowance of 8,000 Btu/h has been made for domestic hot water.
NOTE
THE BOILER MUST HAVE A CONTINUOUS ELECTRICAL SUPPLY WHICH SHOULD BE INTERRUPTED ONLY BY THE BOILER THERMOSTAT
AND THE SAFETY SWITCH. ANY SYSTEM CONTROLS SUCH AS A TIME-SWITCH OR ROOM THERMOSTAT MUST BE WIRED
INDEPENDENT OF THE BOILER TO CONTROL THE CENTRAL HEATING PUMP.
WIRING DIAGRAM -
BLOCKED FLUE SAFETY SWITCH FITTED
4