17
Model 208B BEVELMASTER
®
92-1482 Rev. 190410
5. OPERATION
5.1 GENERAL COMMENTS
Always read the operating instructions before you operate the Model 208B
BEVELMASTER®.
A FRL (Filter/Regulator/Lubricator) is required to protect the warranty on all TRI
TOOL INC. air or hydraulic driven tools.
The motor warranty is void if damage occurs from contaminated air or lack of
lubrication.
The FRL unit must be maintained as required. The frequency will depend on the
basic air supply. Keep the water trap drained, filter cleaned and the lubricator oil
reservoir filled so there's a drop of oil every two (2) to five (5) seconds.
If the unit is to be left idle for 24 hours or more after being run on ‘wet’ air, squirt
oil into the air motor inlet and run the motor for two (2) to three (3) seconds.
This will prevent rusting and ‘freezing’ of the rotor vanes.
For Hydraulic Motors refer to their ‘Operator’s Manual’ for specifics.
When the unit is operated in the vertical position, cutting head up, turn it upside
down and remove the chips and/or other debris after each cutting operation has
been completed.
Tool life may be severely shortened, unless chips and/or other debris are
removed.