Gas Connection Pipework:

The size of the supply pipe for Natural gas should not be less than ¾" B.S.P.  An easily accessible Shut Off 
valve must be fitted in the gas supply adjacent to the appliance. The gas governor regulator supplied with 
the appliance 

must always be fitted

 (including Lpg use) and should  be sited between the Shut off valve 

and appliance .

Before installing appliance always check, using a qualified engineer, that your gas pipe is of large enough 
size for the appliance -- 

Warranty will be invalidated if undersized o pipe work is used.

Set up gas pressure:

When installing on natural gas (G20) -- the manifold pressure should be 5" WC (12.45 mbar) .

When installing on Lpg (G31) -- the manifold pressure should be 10" WC (24.9 mbar) .

When the pressure is being set all burners and Oven(s) should be on at maximum setting.

Technical specification:

Open burners are 35000 btu's each (10.25 kw) = .94 cu mtrs/hour = .67 kg/hr

Ovens -- TSR4 and TSR8 are 30000 btu's (8.79kw) each = .79 cu mtrs/hour = .56kg/hr

Ovens -- TSR6 , TSR10 and TSR12 are 40000 btu's (11.72 kw) each = 1.025 cu mtrs/hour = .73kg/hr

Total gas power:

TSR4 = 49.81kw. 

TSR6 = 73.27kw.

TSR8 = 99.64

(170,000 Btu/Hr)

(250,000 Btu/Hr)

(310,000 Btu/Hr)

TSR10 = 123.06kw.

TSR12 = 146.5kw.

5

Summary of Contents for TSR10

Page 1: ...d in a prominent location This information shall be obtained by consulting the local gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the Installation Operating and Maintenance Instructions thoroughly before installing or servicing this equipment FOR YOUR SAFETY Do not store or use gasoline or other flammable vap...

Page 2: ...use it should be operated by qualified personnel only Never leave the appliance unattended while it is on If you smell gas do not light appliance switch off at Isolating valve and contact your gas supplier or Corgi engineer Must be Commerical Catering equipment registered Preparing the appliance for use Unpack appliance and inspect for any damage All damage must be reported within 24 hours of deli...

Page 3: ...INSTRUCTIONS INSTALLATION OF RANGE LEG AND BACKGUARD ...

Page 4: ...an extraction canopy that conforms to current regulations Adequate supply of fresh air is required to allow proper combustion inadequate air will result in poor performance of appliance and will Invalidate the warranty Minimum c1earnaces from combustible walls Back 100mm 4 inches Sides 305mm 12 inches Minimum clearances from non combustible walls Back 0mm 0 inches Sides 0mm 0 inches This appliance...

Page 5: ...ll be invalidated if undersized o pipe work is used Set up gas pressure When installing on natural gas G20 the manifold pressure should be 5 WC 12 45 mbar When installing on Lpg G31 the manifold pressure should be 10 WC 24 9 mbar When the pressure is being set all burners and Oven s should be on at maximum setting Technical specification Open burners are 35000 btu s each 10 25 kw 94 cu mtrs hour 6...

Page 6: ...56 TSR6 TSRIO TSRl2 LPG gas oven burner injector 1 3mm Size 55 Oven Natural gas pilot injector 3 7mm Size 26 Oven LPG gas pilot injector 4 3mm Size 18 Adjusting minimum output on open burner To adjust the flame when on minimum setting remove the control knob insert a screwdriver through the hole and adjust the screw I until a stable and even flame is achieved 1 Screw to adjust minimum output 2 Gas...

Page 7: ...stability throughout the ON OFF ON control range Check the lighting process along the main burner and check flames are even Check that flame on open burner keeps in touch with the thermocouple adjust as above Check for proper operation of oven pilot flame Check there is a good inflow of fresh air 7 ...

Page 8: ...the knob light the burner and hold in for a further 15 seconds to allow the thermocouple to activate If the flame goes out repeat this operation The burner flame can be adjusted by setting the knob position at a point between Fig 2 and Fig 3 To turn off the flame turn the knob in a clockwise direction to the OFF position Fig 1 8 Fig 1 Off Fig 2 Ignition Low Flame Fig 3 High Flame ...

Page 9: ... knob for 15 seconds to allow thermocouple to activate If the pilot flame goes out repeat above procedures Set oven temperature by selecting required temperature shown on the knob turn knob in an counter clockwise direction these temperatures are in degrees Centigrade Fig 6 To turn off the main burner and leave on pilot turn the knob in a clockwise direction to the ignition position Fig 5 If you l...

Page 10: ... around which gives clearance to the pilot light Oven Daily 1 Wipe clean the inside of the oven making sure you do not touch the thermostat probe on the oven ceiling Scrape any food deposits of the base of the oven with a Nylon or non abrasive scraper 2 Remove oven shelf and clean with soapy water Gas valves must not be touched unless by an authorised engineer Stainless Steel Parts Do not use stee...

Page 11: ...TRI STAR RANGE SERIES 11 ...

Page 12: ...S 13014 60 VALVE COVER TS 13015 72 VALVE COVER 13 TS 20091 30 OVEN DOOR ASSY TS 20090 20 OVEN DOOR ASSY 14 TS 20153 30 OVEN DOOR HANDLE TS 20152 20 OVEN DOOR HANDLE 15 T5 1204 LOGO TRI STAR 16 TS 20143 30 KICK PLATE TS 20142 20 KICK PLATE 17 TS 20159 30 OVEN BOTTOM TS 20150 20 OVEN BOTTOM 18 TS 2021 30 OVEN RACK TS 2020 20 OVEN RACK 19 TS 1106 KNOB THERMOSTAT 20 TS 1105 BEZEL THERMOSTAT 21 TS 2720...

Page 13: ...000 24 LANDING LEGDE TS 21001 36 LANDING LEGDE TS 21002 48 LANDING LEGDE TS 21003 60 LANDING LEGDE TS 21004 72 LANDING LEGDE 38 TS 1050 REGULATOR NAT USED ON 24 36 UNITS TS 1051 REGULATOR LP US D ON 24 36 UNITS TS 1053 REGULATOR NAT HIGH CAPACITY USED ON 48 60 72 UNITS TS 1053L REGULATOR L P HIGH CAPACITY USED ON 48 60 72 UNITS 39 TS 20030R HI SELF SUPPORT CHANNEL R H TS 20030L HI SELF SUPPORT CHA...

Page 14: ...l labor charges for repair of replacement to the extent that such repair or replacement is performed within 35 miles of the office of an authorized service agency within the continental United States and during regular straight time hours Travel outside of the 35 miles and any work performed at overtime or weekend rates would be the responsibility of the owner user Defective parts must be returned...