Gas Connection Pipework:
The size of the supply pipe for Natural gas should not be less than ¾" B.S.P. An easily accessible Shut Off
valve must be fitted in the gas supply adjacent to the appliance. The gas governor regulator supplied with
the appliance
must always be fitted
(including Lpg use) and should be sited between the Shut off valve
and appliance .
Before installing appliance always check, using a qualified engineer, that your gas pipe is of large enough
size for the appliance --
Warranty will be invalidated if undersized o pipe work is used.
Set up gas pressure:
When installing on natural gas (G20) -- the manifold pressure should be 5" WC (12.45 mbar) .
When installing on Lpg (G31) -- the manifold pressure should be 10" WC (24.9 mbar) .
When the pressure is being set all burners and Oven(s) should be on at maximum setting.
Technical specification:
Open burners are 35000 btu's each (10.25 kw) = .94 cu mtrs/hour = .67 kg/hr
Ovens -- TSR4 and TSR8 are 30000 btu's (8.79kw) each = .79 cu mtrs/hour = .56kg/hr
Ovens -- TSR6 , TSR10 and TSR12 are 40000 btu's (11.72 kw) each = 1.025 cu mtrs/hour = .73kg/hr
Total gas power:
TSR4 = 49.81kw.
TSR6 = 73.27kw.
TSR8 = 99.64
(170,000 Btu/Hr)
(250,000 Btu/Hr)
(310,000 Btu/Hr)
TSR10 = 123.06kw.
TSR12 = 146.5kw.