2.5 PC/104 Bus Connector 

 
The table below lists the pins used by the HE104-75W for power and ground on the PC/104 bus. 

 

Pin # 

Signal 

Pin # 

Signal 

Pin # 

Signal 

Pin # 

Signal 

A1 

Not Used 

B1 

GND 

C0 

GND 

D0 

GND 

A2 

Not Used 

B2 

Not Used 

C1 

Not Used 

D1 

Not Used 

A3 

Not Used 

B3 

+5V 

C2 

Not Used 

D2 

Not Used 

A4 

Not Used 

B4 

Not Used 

C3 

Not Used 

D3 

Not Used 

A5 

Not Used 

B5 

Not Used 

C4 

Not Used 

D4 

Not Used 

A6 

Not Used 

B6 

Not Used 

C5 

Not Used 

D5 

Not Used 

A7 

Not Used 

B7 

-12V 

C6 

Not Used 

D6 

Not Used 

A8 

Not Used 

B8 

Not Used 

C7 

Not Used 

D7 

Not Used 

A9 

Not Used 

B9 

+12V 

C8 

Not Used 

D8 

Not Used 

A10 

Not Used 

B10 

Not Used 

C9 

Not Used 

D9 

Not Used 

A11 

Not Used 

B11 

Not Used 

C10 

Not Used 

D10 

Not Used 

A12 

Not Used 

B12 

Not Used 

C11 

Not Used 

D11 

Not Used 

A13 

Not Used 

B13 

Not Used 

C12 

Not Used 

D12 

Not Used 

A14 

Not Used 

B14 

Not Used 

C13 

Not Used 

D13 

Not Used 

A15 

Not Used 

B15 

Not Used 

C14 

Not Used 

D14 

Not Used 

A16 

Not Used 

B16 

Not Used 

C15 

Not Used 

D15 

Not Used 

A17 

Not Used 

B17 

Not Used 

C16 

Not Used 

D16 

+5V 

A18 

Not Used 

B18 

Not Used 

C17 

Not Used 

D17 

Not Used 

A19 

Not Used 

B19 

Not Used 

C18 

Not Used 

D18 

GND 

A20 

Not Used 

B20 

Not Used 

C19 

Not Used 

D19 

GND 

A21 

Not Used 

B21 

Not Used 

 

A22 

Not Used 

B22 

Not Used 

 

A23 

Not Used 

B23 

Not Used 

 

A24 

Not Used 

B24 

Not Used 

 

A25 

Not Used 

B25 

Not Used 

 

A26 

Not Used 

B26 

Not Used 

 

A27 

Not Used 

B27 

Not Used 

 

A28 

Not Used 

B28 

Not Used 

 

A29 

Not Used 

B29 

+5V 

 

A30 

Not Used 

B30 

Not Used 

 

A31 

Not Used 

B31 

GND 

 

A32 

GND 

B32 

GND 

 

 

2.6 LED Enable/Disable 

 

There are no jumpers on the HE104-75W to disable the LED.  If the LEDs must be disabled then the 
current limiting resistor can be easily removed.  The HE104-75W can be factory ordered in this 
configuration for OEM quantities.  Please contact Tri-M sales for details.  

 

2.7 Connector Part Numbers 

 

Description 

Part Number 

Manufacturer   Part Location  

2Pos Plug, MOLEX 0.156" 

09-50-8021-P 

MOLEX 

 Plug for CN2  

CRIMP TERMINAL, 24-18AWG .156" 

08-50-0106 

MOLEX 

Crimps for CN2  

 

Summary of Contents for HE104-75W

Page 1: ...ehicle Power Supply DC to DC Converter Manufactured by TRI M ENGINEERING Engineered Solutions for Embedded Applications Technical Manual P N HE104 75W MAN 13 March 2013 TRI M Technologies Inc 101 1530 Kingsway Port Coquitlam BC V3C 6N6 Canada http www Tri M com Tel 604 945 9565 North America 800 665 5600 Fax 604 945 9566 ...

Page 2: ...INTRODUCTION 4 1 1 GENERAL DESCRIPTION 4 1 2 FEATURES 4 1 3 SPECIFICATIONS 6 CHAPTER 2 CONFIGURATION AND INSTALLATION 7 2 1 INTRODUCTION 7 2 2 POWER CONSIDERATIONS 8 2 3 Main CN2 Input Power Connector 8 2 4 Output CN4 Power Connector 8 2 5 PC 104 Bus Connector 9 2 6 LED Enable Disable 9 2 7 Connector Part Numbers 9 ...

Page 3: ...ental or consequential damages or related expenses resulting from the use of this product even if it has been notified of the possibility of such damages Tri M Engineering reserves the right to revise this publication from time to time without obligation to notify any person of such revisions If errors are found please contact Tri M Engineering at the address listed on the title page of this docum...

Page 4: ... ripple noises below 20mV The low noise design makes the HE104 75W ideal for use aboard aircraft or military applications or wherever EMI or RFI must be minimized The 5VDC and 12VDC outputs are controlled by a constant frequency architecture regulator that provides excellent line and load transient response The HE104 75W has an opto coupled on off input SD to control the outputs of the HE104 75W T...

Page 5: ...sales tri m com Toll free Canada USA 1 800 665 5600 2013 03 14 5 Direct 1 604 945 9565 ...

Page 6: ...age Range 6 to 40V Load Regulation 5V output 60mV Line Regulation 5V output 40mV Output temp drift 5V output 40mV Switching Freq 300kHz Max Input Transient 125V for 250msec Output Ripple 5V output 20mV Conducted Susceptibility 5V output 57db Efficiency 5V output Up to 90 Temp Range 40 to 85C 1 Size PC 104 size mounting holes with PC 104 bus 3 55 W x 3 75 L x 0 6 H 1 As measured on the heat sink sp...

Page 7: ...604 945 9565 CHAPTER 2 CONFIGURATION AND INSTALLATION 2 1 Introduction This chapter describes the configuration and installation of the HE104 75W power supply In addition section 2 2 provides a formula to calculate the available 5VDC Figure 2 1 shows the HE104 75W connectors ...

Page 8: ...hot polarity 6 40VDC Terminal 2 Common 0VDC 2 4 Output CN4 Power Connector Output power is available for use via connector block CN4 and is applied directly to the power and ground connections on the PC 104 bus refer to 2 2 3 for a listing of power and ground connections on the PC 104 bus Note SD is an opto coupled input signal used to turn on off the outputs To enable the HE104 75W outputs a 6 to...

Page 9: ...3 Not Used D13 Not Used A15 Not Used B15 Not Used C14 Not Used D14 Not Used A16 Not Used B16 Not Used C15 Not Used D15 Not Used A17 Not Used B17 Not Used C16 Not Used D16 5V A18 Not Used B18 Not Used C17 Not Used D17 Not Used A19 Not Used B19 Not Used C18 Not Used D18 GND A20 Not Used B20 Not Used C19 Not Used D19 GND A21 Not Used B21 Not Used A22 Not Used B22 Not Used A23 Not Used B23 Not Used A2...

Reviews: